Cat' Message

Mnemonic

4RxCalcQry

4RxCalcRd

4TxCalcQry

4TxCalcRd

5GoLocal

5ContModeQry

5ContModeRd

5ContModeWr

6ShortDeviceQry

6

ShortDeviceRd

6

UnitInfoQry

6UnitInfoRd

7SAFChgWr

7SAFStatQry

7SAFStatRd

8ActionWr

9TxPwrQry

9TxPwrRd

9TxPwrWr

10Log16EventQry

10Log16EventRd

First

Direction

Avail'

 

V1.49*

to unit

V1.49*

from unit

V1.49*

to unit

V1.49*

from unit

V1.37

to unit

V1.37

to Unit

V1.37

from unit

V1.37

to unit

V1.49

to unit

V1.37

from unit

V0.61

to unit

V0.61

from unit

V1.76*

to unit

V1.49*

to unit

V1.49*

from unit

V1.18

to unit

V0.61

to unit

V0.61

from unit

V0.61

to unit

V0.71*

to unit

V0.71*

from unit

Instr' Code

28

29

8

32

33

0

37

51

50

43

26

27

34

Body

Partner

 

Length

(optional)

 

0

RxCalcRd

Query

26

RxCalcQry

Config

0

TxCalcRd

Query

30

TxCalcQry

Config

0

(ack)

Command

0

ContModeRd

Query

2

ContModeQry

Config

2

(ack)

Change

0

ShortDeviceRd

Query

6

ShortDeviceQry

Status

0

UnitInfoRd

Query

18

UnitInfoQry

Status

14

(ack)

Change

0

SAFStatRd

Query

58

SAFStatQQry

Config

4

(ack)

Action

0

TxPwrRd

Query

2

TxPwrQry

Config

2

(ack)

Change

1

Log16EventRd

Query log

178

Log16EventQry

Log events

Function

Calculated Rx parameters, eg intermediate data rates (ie with each overhead as added), Min overhead frame lengths, ESC rates available (current config only)

Calculated Tx parameters, eg intermediate data rates (ie with each overhead as added), Min overhead frame lengths, ESC rates available (current config only).

Local / remote config parameters

The device model number & software version (two most significant digits only)

The model number, version numbers & ID's of the internal cards & software

Enter an unpgrade code, there is no direct corresponding read other than SAFStat

Query the hardware & software feature capability

Front panel `actions`, eg buffer centre, clear slip counters, etc.

Short message for Tx power or carrier on/off without rest of Txmod. To allow changes to Tx power without risk of anything else being reconfigured & hence traffic disturbed (current config only).

To read the traffic log.

10

Log4EventQry

V0.71

to unit

10

Log4EventRd

V0.71

from unit

10

LogDoneMsgWr

V0.71

to unit

11

RemoteKbdWr

TBD

to unit

11

RemoteLCDRd

TBD

from unit

11

Reset

V0.61

to unit

11

TimeDateQry

V0.88

to unit

11

TimeDateRd

V0.88

from unit

11

TimeDateWr

V0.88

to unit

35

36

9

4

10

11

1

Log4EventRd

Query log

46

Log4EventQry

Log events

2

(ack)

End log query

6

RemoteLCDRd

Keyboard

110

RemoteKbdWr

Display

0

(ack)

Command

0

6TimeDateRd

Query

6

TimeDateQry

Status

6

(ack)

Change

Remote operation of unit as if from keyboard. Initial RemoteKbdWr message with either all no key presses or single `Main` keypress initiates first RemoteLCDRd.

The time & date of the internal real time clock. The timeDateWr will probably be used in broadcast mode (address 0), and the TimeDateRd probably used on status screens to display the current unit time to compare log entries to etc.

P300H

P300 Series Modem Installation and Operating Handbook

Page 199

Page 199
Image 199
Paradise P300 specifications First Direction Avail