BER performance with

 

concatenated RS

BER improvement depends on n and k values chosen, but a typical

 

increase in coding gain of 3dB is possible over basic Viterbi mode.

Monitor Functions

Measured FEC input BER (raw channel, not TCM)

 

Estimated FEC output BER (not TCM)

 

Measured Reed-Solomon input BER

 

Estimated Reed-Solomon output BER

 

Measured deframer FAW BER

 

Measured Eb/No (not based on channel BER, range: 3.0-15.0dB,

 

accuracy ±0.2dB).

 

Measured frequency offset (± 100 Hz resolution)

 

 

Clocking and Buffering

Clock Loops

 

Frequency locked loops give phase hit immune operation even with poor

 

 

 

clock sources such as routers etc.

 

Tx Clocking

 

Internal Reference (see Internal Reference below for stability)

 

 

 

External - tracking range ±100 ppm / min.

 

 

 

Rx Timing - slaves Tx internally generated timing from Rx clocking

 

 

 

whatever Rx clocking mode is selected eg with Rx=Satellite for loop

 

 

 

timing (with full asymmetric rate capability), or with Rx=Station for

 

 

 

both Tx & Rx clocking slaved to Station Clock (again with full

 

 

 

asymmetric rate capability).

 

Rx Clocking

 

Clock from satellite (Buffer disable)

 

 

 

Transmit input clock - (plesiochronous, includes full asymmetric rate

 

 

 

operation)

 

 

 

Internal Reference (see Internal Reference below for stability)

 

 

 

DCE External timing clock (DTE interface only).

 

 

 

Station reference (see below)

 

Internal Reference

 

P300: +/-1PPM

 

 

 

P310: Default as per P300. Options: 7x10-7 per year (P313B), 1x10-7

 

 

 

per year (P313C), 7.5x10-8 per year (P313D).

 

Station References inputs

75

BNC female, transformer isolated 1MHz to 10MHz in 1kHz steps

 

 

 

SS

 

 

 

 

(accepts sinusoid >0dBm or squarewave eg G.703 para 10)

 

 

120 RS422 compatible input, 1kHz to 10MHz in 1kHz steps

 

 

 

When set to 10MHz, the station reference may replace internal reference

 

 

to all internal circuitry (eg IF synths). The unit automatically switches back

 

 

to the internal reference if the station reference fails.

 

Buffer Size

 

Selectable in 1 ms increments from 0 to 99 ms. Automatically adjusted

 

 

to slip an integer multiple of terrestrial multiframe length for framed rates

 

 

(T1/E1).

 

 

 

Buffer storage is 32kBytes, so above 2.6 Mbps max buffer size reduces

 

 

linearly from 99 ms to 52ms at 5.0Mbps

 

 

 

 

P300H

P300 Series Modem Installation and Operating Handbook

Page 26

Page 26
Image 26
Paradise P300 specifications Clocking and Buffering