6.16.6 Test, Int' BERT, PATTERN Menu

BERT Pattern: [2^15-1]

1:2^11-1(2047) 2:2^15-1 3:2^20-1

Test, Internal BERT, Pattern Menu

The test pattern may be selected to be one of three standard patterns as 211-1(2047), 215-1, or 220-1.

6.16.7 Test, Int' BERT, MODE Menu

BER Test mode [1 Min]

1=One minute sliding window 2=Manual

Test, Internal BERT, Mode Menu

The test mode may be one of the following:

AUTOLOG

The BERT mode is fixed in Autolog because the unit is configured to Autolog the

 

results of the BER test at the user defined Autolog period. In Autolog mode the

 

screen above is not shown, but rather a warning “Cannot select 1 Min/Manual

 

mode while AUTOLOG of PRBS results is active (YES)” is displayed. To be able

 

to manually select the BERT mode auto-logging of the BER result must be

 

disabled by either setting the Autolog period to zero (Main, Log, Autolog) or by

 

clearing the flag requesting it to log the BERT results on the subsequent Autolog

 

screen.

ONE MINUTE

One Minute sliding window mode displays the average BER over the last 1

 

minute. It does this by storing the error results second by second in a circular

 

table 60 entries long and recalculating the average BER each second. For any

 

seconds where the BERT is `out of sync` a zero entry is made in the table. The

 

average BER over the one minute period is calculated based on only the non-

 

zero entries (when sync is recovered).

MANUAL

Manual mode allows the operator to manually start, stop & restart tests which

 

may run for up to 27 hours (99,999 seconds), at which point the results are

 

frozen.

P300H

P300 Series Modem Installation and Operating Handbook