Text on Display

Rx Warn: Rx BER below user threshold

Rx Warn: Buffer slips too frequent (YES)

Rx Warn: Ins' bearer BER>user threshold

Rx Warn: Buffer overflow & recentre

Rx Warn: Buffer underflow & recentre

Rx Warn: Ins' mux slipping data to sync

Rx Warn: Ins' mux slipping sig' to sync

Rx Warn: RS Decoder FIFO slip

Rx Warn: Insert mux sig' FIFO slip

Description / Cause / Notes

The final Bit Error Rate is worse than the user threshold set for a deferred alarm (Change, User-Opt, Thresholds, User BER). This may be used as an advance warning of service degradation. The source for the BER measurement is user defined (Change, User-Opt, Operation, Satellite, BER est’). Normally this should be set to “Auto”, however it may be user set to other BER sources if required. It is possible to manually set the source to the inner FEC (Turbo/Vit/Seq), even when the outer FEC (RS) is active, thereby not including the effects of the RS error correction in the displayed user BER. Check this remains set to “Auto” unless there is good reason.

The minimum period between buffer slips is less than the user threshold set for a deferred alarm (Change, User-Opt, Thresholds, Buffer Slip). This is used as an advance warning that the clock accuracy is less than expected causing the buffer to slip more frequently in turn causing data errors. The alarm may be muted by pressing YES. Check the system clocking to see if a clock has degraded. If the clocks are correct but the buffer is slipping too frequently increasing the buffer size will increase the period between buffer slips (but at the cost of increased delay).

This fault will only be displayed if the modem if fitted with an interface which provides four ports for separate input and output of separate Tx/Drop and Rx/Insert PCM bearers. The Bit Error Rate at the Rx bearer input (measured on the PCM Frame Alignment Words) is worse than the user set threshold for a deferred alarm (Change, User-Opt, Thresholds, User BER). See note 3

The Doppler / Plesiochronous buffer has filled, and automatically slipped to position itself back in mid position. Half the buffer capacity will have been discarded, but for framed data (eg T1/E1 only) frame sync will not be lost if the user option (Change, User-Opt, Operation, Terr/Sat, Buffer MF Slip) is set to “Adjust”, to ensure buffer slips are an integer multiple of the multiframe length.

The Doppler / Plesiochronous buffer has emptied, and automatically slipped to position itself back in mid position. Half the buffer capacity will have been repeated, but for framed data (eg T1/E1 only) frame sync will not be lost if the user option (Change, User-Opt, Operation, Terr/Sat, Buffer MF Slip) is set to “Adjust”, to ensure buffer slips are an integer multiple of the multiframe length.

After a break in the Rx signal, the Insert Mux is `bit slipping` data in the Doppler Buffer to bring the data taken out of the Buffer by the Insert Mux into step with the terrestrial (bearer) frame timing.

See above text, but thistime with regard to CAS signalling data not the main data path.

The FIFO which interfaces the RS Decoder to the Deframer has slipped (full or empty). This should never occur in operation (contact factory).

The FIFO which carries the CAS signalling from the Doppler Buffer to the Insert Mux has slipped (full or empty). This should never occur in operation (contact factory).

Relays