Paradise P300 specifications Freeze, Nominal, Maximum

Models: P300

1 228
Download 228 pages 21.78 Kb
Page 75
Image 75

This sets a `tolerance window` on the monitored Eb/No. The AUPC will only attempt to restore the monitored Eb/No to the target Eb/No when the monitored Eb/No moves outside the tolerance window. This It is to prevent the AUPC continuously adjusting the power to compensate for minor normal Eb/No variations.

When the monitored Eb/No moves outside the tolerance window the AUPC will attempt to restore it back to the target value (ie not just back inside the tolerance window again).

6.6.24 Change, Tx, Modulator, AUPC, CARRIER LOST ACTION Menu

Set AUPC power on carrier lost: [Nominal]

1=Freeze 2=Nominal 3=Maximum

Change, Tx, Modulator, AUPC, Comms lost action Menu

This screen sets what action the AUPC It is to take locally if it looses communications with the distant modem (ie presumably there It is a significant fade and the distant demod has lost lock).

FREEZE

The carrier power It is frozen at its current value.

NOMINAL

The AUPC delta power It is reset to zero so the carrier returns to its nominal

 

power.

MAXIMUM

The AUPC delta power increases to the maximum power limit as set on the

 

AUPC Max positive delta power screen.

P300H

P300 Series Modem Installation and Operating Handbook

Page 75

Page 75
Image 75
Paradise P300 specifications Freeze, Nominal, Maximum