Paradise P300 CHANGE, USER-OPT Menu, Change, User-Opt, Thresholds Menu, User BER, Buffer Slip

Models: P300

1 228
Download 228 pages 21.78 Kb
Page 101
Image 101

6.10CHANGE, USER-OPT MENU

User options: 1:Alarm thresholds 2:Operation 3:Display 4:Analog o/p

Change, User-Opt Menu

This screen allows access to all the user options, which are described in the following paragraphs.

6.10.1 Change, User-Opt, THRESHOLDS Menu

Thresholds: 1:Final BER [1.0E-5] 2:Demod Eb/No [6.0]dB

3:Buffer slip [24]hrs 4:DISTANT Eb/No[8.5]dB

Change, User-Opt, Thresholds Menu

This screen allows the operator to set thresholds at which a deferred alarm is raised, to allow action to be taken before the service degrades too far.

USER BER

The operator may enter a BER at which the deferred alarm is raised should the

 

estimated USER BER degrade below this threshold.

DEMOD Eb/No

The operator may also or alternatively set a deferred alarm threshold for the

 

Eb/No measured by the demodulator. This is the Eb/No as displayed on the

 

screen whenever the demodulator status is displayed.

BUFFER SLIP

The operator may also instruct the modem to raise the deferred alarm if the

 

interval between buffer slips is less than a preset threshold. The threshold is set

 

in hours, and may be for example set to 960 hours (40 days) or 1728 (72 days)

 

to warn if the criteria for clock accuracies for a specific service are not being met.

DISTANT Eb/No

If the AUPC feature is active in either `Maintain Eb/No` or `Monitor Distant` modes

 

(refer to AUPC in section 8.11.1 on page 154) the operator has the facility to raise

 

a deferred alarm if the DISTANT Eb/No falls below the user set threshold. This

 

can be used in conjunction with the AUPC to indicate when the AUPC has

 

reached the user set limit for maximum Tx power, but the distant Rx Eb/No has

 

still fallen below the desired limit.

6.10.2 Change, User-Opt, OPERATION Menu

User options: 1:Default 2:Actions 3:Terr’

4:Sat’ 5:Terr/Sat 6:Alarms

Change, User-Opt, Operation Menu

The operator has control over may parameters which are the subject of either personal or company preference. A single menu choice DEFAULT ALL resets these to the Paradise Defaults which are listed in the following paragraphs along with each parameter.

P300H

P300 Series Modem Installation and Operating Handbook

Page 101

Page 101
Image 101
Paradise P300 specifications CHANGE, USER-OPT Menu, Change, User-Opt, Thresholds Menu, User BER, Buffer Slip