Elk Setting Up the M1XEP: Steps for Configuration and Connectivity

Page 7

1.4.Before continuing with the setup and configuration, you must connect to the Control over the network.

a.Verify that the URL/IP and Port setting are correct on the "Account Details" screen.

b.Make sure the "RP Access Code" is set to the correct value programmed into the control. (default=246801)

c.From the RP Connection Menu, choose the "Network" method.

If everything is setup correctly, ElkRP should now connect to the control through the M1XEP.

1.5.Once connected, click the 'M1XEP Setup' button once again to continue the configuration. Click the 'TCP/IP Settings' tab. At the top, a device name of up to 16 characters may be entered. This name is used only during subsequent “Find” processes to quickly identify an M1XEP when there are more than one on the same network.

1.6.As previously discussed, the M1XEP is factory defaulted to DHCP, which means that it expects to be assigned a “dynamic” IP address. Be aware that a “dynamic” IP address can periodically change for many reasons, including a power down/up cycle. This is OK if you are utilizing DDNS service (see step 6 on page 9). However, you may optionally assign the M1XEP a permanent “static” address, if permitted by the network. This will also involve setting values for subnet mask, default gateway, and primary DNS server. These settings can be obtained from your network administrator or Internet service provider.

Note: If the M1XEP is programmed with a static IP address, and later changed to obtain a dynamic IP address from a DHCP server, it will revert back to the last programmed static IP address if it fails to obtain a dynamic IP address from the DHCP server after 1 minute. If a static IP address has not been programmed and the M1XEP cannot obtain a dynamic IP address from a DHCP server it will default to an IP address of 192.168.0.251.

1.7.Some third party devices use a TCP or non-secure port for standard (unencrypted) communications on the local network. If this port is needed, select “Enable Non-Secure Port" and enter the appropriate port number. Values between 1024 and 49151 are valid. The recommended (default) port is 2101. This port should not be mapped outside the local network, for security reasons. If the port is not needed, it should be disabled.

1.8.ElkRP and some third party devices use a SSL or secure port for encrypted communications. Enter the appropriate value for the secure port. Values between 1024 and 49151 are valid. The recommended (default) port is 2601. If you intend to access the Control through the Internet, this port should be mapped (port forwarded) to outside the local network via a router.

2. Send Changes to the M1XEP and Save

Send the changes by clicking the send button located at the bottom of the setup screen. You may receive a message that informs you that the changes will cause the M1XEP to reconfigure itself, and it must be rebooted after the send is complete. Click 'Yes' on this screen. The send process may take up to a minute. Once the process is complete, you will receive a message that the M1XEP will reboot. Click 'OK'You. must reboot the M1XEP before the changes will take effect. The reboot will take up to 2 minutes. A connection with the M1XEP cannot be re-established until the reboot process is complete. Click 'Save Account' under the "File" menu to save the changes to the database.

ELK-M1XEP Installation Manual

Page 7

Image 7
Contents ELK-M1XEP Table of Contents Application Features and SpecificationsWAN Basics of NetworkingInstallation and Hookup Basic Network Setup Configuration and SetupSend Changes to the M1XEP and Save Email Notification Setup optional Setup of Web Browser User Name & Password optionalSetup of Ddns future Central Station Setup futureELK-M1XEP Installation Manual Connecting ElkRP to the Control over a Network During this Process Updating the M1XEP FirmwareUsing the Virtual Keypad Application ELK-M1XEP Installation Manual ELK-M1XEP Installation Manual ELK-M1XEP Installation Manual ELK-M1XEP Installation Manual ELK-M1XEP Installation Manual Glossary of Networking Terms XEP0605

M1XEP specifications

The Elk M1XEP is a highly versatile and powerful control and communication module designed for the Elk M1 Gold and M1EZ8 security systems. This innovative device extends the functionality of your security system by allowing remote access and control over the network. With the M1XEP, users can efficiently manage their alarm systems, monitor the status of devices, and receive real-time notifications from anywhere with internet connectivity.

One of the standout features of the Elk M1XEP is its built-in Ethernet port, which enables direct connection to a local area network (LAN). This connectivity allows for seamless integration with home automation systems and third-party applications, making it ideal for tech-savvy users looking to enhance their home security. The module is designed with a user-friendly interface, allowing homeowners to easily configure and maintain their security settings through any compatible web browser.

Another significant advantage of the Elk M1XEP is its compatibility with various mobile devices. With the integration of apps available for both iOS and Android platforms, users can remotely access their security system on-the-go. This capability ensures that homeowners can always stay connected to their property, receiving alerts and responding to incidents promptly.

In terms of communication technologies, the Elk M1XEP supports IP communication and can notify users of any security breaches via email, text messages, or push notifications. This flexibility is essential for ensuring prompt action in case of emergencies. Furthermore, the device is compatible with the Elk M1 Control Panel, which allows for expanded features such as automation of lighting, temperature control, and even integration with popular smart home platforms.

The M1XEP boasts robust security features, including encryption, which safeguards the data transmission between the control panel and other devices. With this level of protection, users can have confidence that their security information is safe from prying eyes.

Overall, the Elk M1XEP is an indispensable addition for anyone looking to maximize the capabilities of their Elk security system. With its advanced features, seamless connectivity options, compatibility with mobile devices, and enhanced security measures, it stands as a leading choice for homeowners seeking a smarter, more reliable way to protect their property.