Notice

BSMI EMC Statement — Taiwan

This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

Safety Compliance

Please read the following safety information carefully before installing the RPS:

WARNING: Installation and removal of the unit must be carried out by qualified personnel only.

The unit must be connected to an earthed (grounded) outlet to comply with international safety standards.

Do not connect the unit to an A.C. outlet (power supply) without an earth (ground) connection.

The appliance coupler (the connector to the unit and not the wall plug) must have a configuration for mating with an EN 60320/IEC 320 appliance inlet.

The socket outlet must be near to the unit and easily accessible. You can only remove power from the unit by disconnecting the power cord from the outlet.

This unit operates under SELV (Safety Extra Low Voltage) conditions according to

IEC 60950. The conditions are only maintained if the equipment to which it is connected also operates under SELV conditions.

France and Peru only

This unit cannot be powered from ITsupplies. If your supplies are of IT type, this unit must be powered by 230 V (2P+T) via an isolation transformer ratio 1:1, with the secondary connection point labelled Neutral, connected directly to earth (ground).

Impédance à la terre

iii

Image 5
Contents VSER-RPU-SYS Page Page Regulatory Compliance Information Bsmi EMC Statement Taiwan Power Cord Set France et Pérou uniquement Declaration of Conformity Contents Tables Figures Figures Features and Benefits Chapter About the Redundant Power SupplyOverview Front and Rear PanelsLED LEDsInstallation Chapter Installing the Redundant Power SupplyEquipment Checklist Selecting a SiteGettingHelp Package ContentsMounting MountingAttaching the Brackets Desktop or Shelf Mounting Connecting Switches to the RPSConnecting Several Switches to an RPS Power and Cooling Problems Appendix a TroubleshootingDiagnosing RPS Indicators Troubleshooting Physical Characteristics Appendix B SpecificationsCompliances SpecificationsIndex Index Index-2 Page E032004-R01 150200042500A