Enterasys Networks Mid-Span Power Hub manual Probably a faulty data link in the load

Page 24

Troubleshooting

Table 3-1 Troubleshooting Checklist (continued)

Problem

Recommended Action

 

 

The Mid-Span Power Hub operates and the

Verify that the Detect/Power Forwarding (blue)

load device works, but there is no data link.

LED for the port is “on.” Verify that the Mid-Span

 

Power Hub is connected to the Ethernet

 

network with a good connection.

 

Verify that the Ethernet cable is Category 5, 5e,

 

or 6 and is less than 100 meters in length from

 

the Ethernet source to the load.

 

Try to connect a different device over the same

 

port. If it works and a link is established, there is

 

probably a faulty data link in the load.

 

Try to reconnect the load into a different output

 

port (remember to move the input port

 

accordingly). If it works, there is probably a

 

faulty output or input port in the Mid-Span

 

Power Hub or a bad RJ45 connection.

 

 

The Mid-Span Power Hub operates, but one of

Move the load into a different output port. If the

the ports is powering a load without turning the

LED turns “on,” there is a fault in the previous

“Power” LED on.

output port.

 

 

3-2 Troubleshooting

Image 24
Contents Mid-Span Power Hub Port User’s Guide Page Regulatory Compliance Information Industry Canada Notice ONE-YEAR Limited Warranty Enterasys Networks, Inc Firmware License Agreement Page Page Contents Viii About This Guide PurposeWho Should Use This Guide Document Conventions Getting HelpGetting Help Getting Help Xii About This Guide Functions and Features Port IndicatorsIntroduction Port Indicators Introduction Installation and Connection Verifying the KitKit Contents Configuration for the 24-Port Mid-Span Power Hub Technical ConsiderationsTypical Configuration for a 24-Port Mid-Span Power Hub Powering Up Module Bank for the 24-Port Mid-Span Power HubPowering Up Installation and Connection Troubleshooting Troubleshooting Checklist Problem Recommended ActionProbably a faulty data link in the load Hardware Specifications Regulatory Compliance StandardsProduct Standards Model BL-69524ENTPhysical/Mechanical Specifications Electrical Specifications Model BL-69524ENT