Network Cable Requirements
Copper
Figure 2-1 specifies the cable types and length constraints for the various copper interfaces on the VH-4802.
Table 2-1. Copper Cable Specifications
Interface Type | Cable Requirement | Maximum Length |
Category 3 or 5 Unshielded Twisted | 100m (328 ft.) | |
| Pair (UTP) |
|
Category 5 UTP | 100m (328 ft.) | |
|
|
|
Fiber
Figure 2-2 specifies the fiber types, bandwidth requirements, and length constraints for the Fast Ethernet fiber interface on the fiber optic media modules.
Table 2-2. Fast Ethernet Fiber Specifications
Interface Type | Fiber Type | Fiber Diameter | Maximum Length (m) |
|
| (microns) |
|
62.5 | 2,000m (6,560 ft.) | ||
connectors) |
|
|
|
10 | 10 km (6.21 miles) | ||
connectors) |
|
|
|
Figure 2-3 specifies the fiber types, bandwidth requirements, and length constraints for the Gigabit Ethernet short-wavelength fiber interface on the fiber optic media module.
Table 2-3. 1000Base-SX Fiber Specifications
Fiber Diameter | Modal Bandwidth @ 850 nm | Range |
(microns) |
|
|
62.5 µm MMF | 160 MHz/km | |
62.5 µm MMF | 200 MHz/km | |
50 µm MMF | 400 MHz/km | |
50 µm MMF | 500 MHz/km | |
|
|
|
24 Installation |