DeWalt MD3220I manual

Page 18

Dell PowerVault MD32xxi Configuration Guide for VMware ESX4.1 Server Software

esxcfg-nics –l

The output will look similar to this:

Name PCI Driver Link Speed Duplex MAC Address MTU

vmnic0 03:00.00 bnx2 Up 1000Mbps Full 00:21:9b:8b:4b:b0 1500

This will list all of the adapters in the system. Assign the NICs that are physically connected to the SAN infrastructure and to the vSwitch. The following command assumes that we are assigning vmnic1, vmnic2, and vmnic3 to the vSwitch.

esxcfg-vswitch –L vmnic1 vSwitch2

esxcfg-vswitch –L vmnic2 vSwitch2

esxcfg-vswitch –L vmnic3 vSwitch2

Once again, to verify the configuration type the following command to list the vSwitch information:

esxcfg-vswitch –l

Your output will look similar to the following. Note the new vmnics that were assigned to the vSwitch under uplinks.

Switch Name

Num Ports

Used Ports

Configured Ports MTU Uplinks

vSwitch2

64

9

64

9000

PortGroup Name VLAN ID Used Ports

Uplinks

 

iSCSI3

 

0

1

vmnic1,vmnic2,vmnic3

iSCSI2

 

0

1

vmnic1,vmnic2,vmnic3

iSCSI1

 

0

1

vmnic1,vmnic2,vmnic3

Adding a NIC can also be configured and verified in the vCenter GUI. Remember that the polling of vCenter is not instant so a refresh might need to occur to see the latest changes. To configure this same process from the GUI, first navigate to the Networking section on the ESX host you are configuring. Configuration -> Networking.

From here, click Properties on the vSwitch2.

Page 16

Image 18
Contents Page Page Table of Contents Terminology/Glossary Introduction Implementing ESX4.1 on the MD32xxi Storage ArrayArchitectural Setup Supported Hardware and SoftwareEstablishing Sessions to a SAN PowerVault MD32xxi Storage Setup and Configuration Select Manually Define Hosts Page ISCSI Software Initiator Configuration on ESX4.1 Server Select Configuration-Security Profile on the ESX serverPage Page Clustering with ESX4.1 / Creating DRS Clusters Configure vSwitch & Enable Jumbo Frames Add iSCSI VMkernel PortsPage Assign Network Adapters Page Page Associate VMkernel Ports to Physical Adapters Page Page Enable VMware iSCSI Software Initiator Page Binding VMkernel Ports to iSCSI Software Initiator Static Connect to PowerVault MD32XXi Storage Click the Dynamic Discovery tabPage Page Page Connect to a Volume on PowerVault SAN Contact Information Enabling VMware Native Multipathing MRUStep A1 Configure vSwitch and Enable Jumbo Frames Appendix aStep A2 Add iSCSI VMkernel Ports Networking Step A3 Assign Network Adapters Step A4 Associate VMkernel Ports to Physical Adapters Page Step A5 Enable VMware iSCSI Software Initiator Step A6 Binding VMkernel Ports to iSCSI Software InitiatorPage Vmk5 iSCSI6 IPv4 Step A7 Connect to the Dell PowerVault Storage