Digi TS8, 16 manual Configuring Inbound PPP Connections Example

Page 40

7.To configure an IP address for the local end of the PPP connection, enter the following com- mand:

set user name=name localipaddr=ip-address

where name is the user’s name and ip-addressis the IP address to assign to the local end of the

PPPconnection. This address must be unique. That is, no other user can be assigned this address and it cannot be the IP address for the Ethernet interface.

Example: set user name=pppin localipadr=199.1.1.2

Configuring Inbound PPP Connections: Example

This example shows a very simple PPP inbound configuration. Here are some points on this configuration:

The port is set up for inbound connections (dev=min).

RTS and CTS are used for flow control.

The baud rate has been set to 115000 bps.

The user has been configured to use an IP address pool

set ports range=3 device=min

set flow range=3 ixon=off ixoff=off rts=on cts=on set line range=3 baud=115000

set user name=pppin protocol=ppp netservice=on defaultaccess=netservice set user name=pppin ipaddr=ippool

set user name=pppin localipadr=199.1.1.2

8-4

Configuring Inbound PPP Connections: Command Line

Image 40
Contents PortServer TS 8/16 Configuration and Administration Guide Page Contents Chapter Configuring Users Page Introduction This ChapterSetup Overview About This Guide About Entering Commands on the Command LineSupported Devices Access Resource CD Card Other Documents in the LibraryAbout Configuration Methods Configuring the PortServer TS 8/16 from a Telnet SessionConfiguring the PortServer TS 8/16 from the Web Interface Downloading a Configuration FileConfiguration Prerequisites Logging On As Root from the Command LineAccessing the Command Line from a Telnet Session Accessing the Configuration from the Web InterfaceConfiguring the IP Address Options for Configuring the IP Address and Mask OptionsProcedure Configuring the Ethernet Interface with DPA-RemoteStarting Point Configuring the IP Address Using Ping-ARP Configuring the Ethernet Interface from the Command Line Configuring an IP Address using Dhcp and RarpManual Configuration Procedure Manual Configuration ExampleConfiguring an IP Address using Dhcp and Rarp Configuring Ports for RealPort What is RealPort? Configuring the RealPort SoftwareConfiguration Options About RealPortConfiguring Ports Web Interface Configuring Ports for RealPort Command Line ExampleConfiguring Ports for Printers Configuration Considerations Configuring Ports for Printers Web Interface Configuring Printer Connections Command LineTips for telnet and rsh Printing Related InformationConfiguring Printer Connections Command Line Configuring a Port for Direct-Access Printing Configuring a Port for Direct-Access Printing Configuring Ports for Terminals Configuring Ports for Terminals Command Line Configuring Ports for Terminals Web InterfacePort Defaults Configuring Typical PC Connections About Computer ConnectionsAbout Computer Connections Configuring Ports for Modems Tips on Configuring a Modem Configuring Ports for Modems Web Interface Before You Begin Configuring PPP Configuring PPP Connections Web Interface Configuring Inbound PPP Connections Command Line Configuring Inbound PPP Connections Example Configuring Outbound PPP Connections Command Line Set user name=name n1=telephone-number Configuring IP Routing Introduction to Routing What is RoutingTypes of Routing About RIP Routing Updates PortServer TS 8/16 Participation in RIP Updates Example Route Using the Ethernet Interface Configuring Static RoutesExample Route Using a PPP Link Configuring Dynamic Routes Using RIP Example Dynamic RoutesConfiguring Proxy ARP Configuring Proxy ARP Configuring Autoconnection Configuring Autoconnection By Port Command Line Configuring a Port for Autoconnection Web InterfaceAbout Autoconnection Configuring a User for Autoconnection Web Interface Configuring a User for Autoconnection Command LineConfiguring a User for Autoconnection Command Line Configuring Console Management Configuring Console Management Command Line Configuring Console Management Web InterfaceAbout Console Management Example SSH2 and Menu Access Example Alternate IP Addresses10-4 Configuring Security Features Controlling Access to the PortServer TS 8/16 Configuration Controlling Access to Inbound PortsControlling Access to Outbound Ports Controlling Access to the PortServer TS 8/16 Command LineUsing Radius to Authenticate Users What is RADIUS?Radius Components Radius Table KeyRadius Accounting Attributes RFC Configuring Radius Web InterfaceHow Radius Works Configuring Radius Command Line Radius Command Line Configuration ExampleIssuing User Passwords Password Protection Configuring SSH Version 2 for Secure CommunicationUsing a Public Key Configuring DNS About the Domain Name System Procedure for Using a Name Server Configuration ProceduresProcedure for Using a Host File 13-4 Configuring Snmp About Snmp and the PortServer TS 8/16 Agent Configuration Procedure Command Line Configuration Procedure Web InterfaceConfiguration Example 14-4 Managing the OS and Configuration Upgrading the OS Firmware Web Interface Upgrading the OS Firmware Command Line Prerequisite TaskConfiguring PortServer TS 8/16 from a Remote Host When To Use Remote ConfigurationRules for Editing a Configuration file Copying the Configuration File to a HostCpconf fromhost=199.250.121.12cnfg-fle Resetting the Configuration to Defaults RadiusConfiguring Users Common User Features About Configuring UsersConfiguration Methods Configuring a User Web Interface Configuring a User Command Line Examples Configuration Examples Terminal Server Configuration Without RealPort ConfigurationConfiguration Notes IllustrationTerminal Server Configuration Using Autoconnection Terminal Server Configuration Using RealPort Dial-In PPP Connection Using Radius Dial-In PPP Connection Using Radius PortServer TS 8/16 Troubleshooting Symptom PortServer TS 8/16 Does Not Boot IntroductionSymptom Cannot Telnet to the PortServer TS 8/16 AssumptionsSymptom Trouble Accessing a Port Running PortServer TS 8/16 Hardware DiagnosticsProcedure Running the Post from a Terminal Procedure Running the Post Using the LEDsRunning PortServer TS 8/16 Post Troubleshooting Tftp Problems Verifying Tftp on a Unix SystemCommand Line Procedure Resetting PortServer TS 8/16 Configuration to DefaultsFront Panel Procedure Verifying the PortServer TS 8/16 IP Address 17-9 Checking for Duplicate IP Addresses Pinging an IP Address Verifying the Network Cabling Verifying the RealPort Process AIX Verifying the RealPort ProcessHP-UX Verifying the RealPort Process Linux Verifying the RealPort ProcessWindows 2000 Verifying the RealPort Service Windows NT Verifying the RealPort ServiceSolaris Verifying the RealPort Process Checking and Changing Port Configuration RealPortDigi Contact Information Digi International Bren Road East Minnetonka, MN

16, TS8 specifications

The Digi TS8 and TS16 are advanced devices within the Digi TransPort series, which are renowned for their versatility in providing robust network connectivity solutions. Designed to cater to the needs of IoT (Internet of Things) applications, these routers are excellent for businesses that require reliable, high-performance communication across various environments.

One of the standout features of the Digi TS8 and TS16 is their cellular connectivity. Both models support multiple cellular bands, including 4G LTE, ensuring that users can maintain a stable and fast internet connection even in remote locations. This makes them ideal for applications like smart grid management, digital signage, and industrial telemetry, where constant connectivity is crucial.

Another significant aspect of the Digi TS8 and TS16 is their dual SIM capability. This feature allows for seamless failover between two cellular networks. In cases where one network experiences an outage, the device automatically switches to the secondary network, thus minimizing downtime and maintaining business continuity. This redundancy is a vital characteristic for mission-critical applications.

The routers also support various WAN technologies, including LTE, Ethernet, and Wi-Fi, providing flexibility for diverse deployment scenarios. With their comprehensive networking capabilities, the Digi TS8 and TS16 can be integrated into existing infrastructures with ease.

In terms of security, these devices offer a robust suite of features designed to safeguard data. They come equipped with advanced firewall capabilities, VPN support, and secure tunneling protocols, ensuring that data transmitted across the network remains protected against unauthorized access.

Additionally, management and monitoring are made easy with Digi’s intuitive web interface and cloud management platform. Users can remotely configure, monitor, and manage their devices, enabling efficient performance tracking and troubleshooting from anywhere in the world.

Both the Digi TS8 and TS16 are built to endure harsh environmental conditions, boasting an industrial-grade design that adheres to rigorous standards. They can operate effectively in extreme temperatures and are resistant to dust and moisture, making them suitable for outdoor and rugged deployments.

Overall, the Digi TS8 and TS16 provide an extensive set of features and characteristics that address the growing demands of modern connectivity. Their reliability, security, and flexible deployment options make them a preferred choice for businesses looking to harness the power of IoT technology. Whether for industrial applications or remote site management, these devices lead the market with their performance and adaptability.