Daxten DSR8020, DSR2020, DSR4020, DSR1020 manual Cabling installation, maintenance and safety tips

Page 86

78DSR Switch Installer/User Guide

Table E.1: UTP Wiring Standards (Continued)

Pin

EIA/TIA 568A

EIA/TIA 568B

 

 

 

7

white/brown

white/brown

 

 

 

8

brown

brown

 

 

 

Cabling installation, maintenance and safety tips

The following is a list of important safety considerations that should be reviewed prior to installing or maintaining your cables:

Keep all CAT 5 runs to a maximum of 10 meters each.

Maintain the twists of the pairs all the way to the point of termination, or no more that one-half inch untwisted. Do not skin off more than one inch of jacket while terminating.

If bending the cable is necessary, make it gradual with no bend sharper than a one inch radius. Allowing the cable to be sharply bent or kinked can permanently damage the cable’s interior.

Dress the cables neatly with cable ties, using low to moderate pressure. Do not over tighten ties.

Cross-connect cables where necessary, using rated punch blocks, patch panels and components. Do not splice or bridge cable at any point.

Keep CAT 5 cable as far away as possible from potential sources of EMI, such as electrical cables, transformers and light fixtures. Do not tie cables to electrical conduits or lay cables on electrical fixtures.

Always test every installed segment with a cable tester. “Toning” alone is not an acceptable test.

Always install jacks so as to prevent dust and other contaminants from settling on the contacts. The contacts of the jack should face up on the flush mounted plates, or left/right/down on surface mount boxes.

Always leave extra slack on the cables, neatly coiled in the ceiling or nearest concealed location. Leave at least five feet at the work outlet side and 10 feet at the patch panel side.

Choose either 568A or 568B wiring standard before beginning. Wire all jacks and patch panels for the same wiring scheme. Don’t mix 568A and 568B wiring in the same installation.

Always obey all local and national fire and building codes. Be sure to firestop all cables that penetrate a firewall. Use plenum rated cable where it is required.

Image 86
Contents DSR Switch For models DSR1020, DSR2020, DSR4020, DSR8020USA Notification Japanese Approvals Safety and EMC Standards Table of Contents Console Menu Other Console Main Menu Options List of Figures Vi DSR Switch Installer/User Guide List of Tables Viii DSR Switch Installer/User Guide Features and Benefits Reduce cable bulkEasy access to any target device Access the DSR switch via network connectionTwo modes of access Network SoftwareServer DSR1020 DSR2020 DSR4020 DSR8020Safety Precautions Rack mount safety considerationsInstallation Installation OverviewBasic DSR Switch Configuration EthernetGetting Started Setting up your networkSupplied with the DSR switch Additional items neededConnecting the DSR Switch Hardware To connect and power up your DSR switchTo connect a Dsriq module to a server To connect a Dsriq module to a serial deviceVerifying the Connections To adjust mouse settings on Windows NT using default drivers To adjust mouse settings using Sun Solaris drivers To adjust mouse settings using IntelliPoint driversTo adjust mouse settings using Red Hat Linux drivers Viewing and Selecting Ports and Servers To access the Oscar interface Main dialog boxControlling Your System at the Local Port Selecting target devices Viewing the status of your DSR switching systemOscar Interface Status Symbols Symbol Description To select target devicesTo soft switch to a target device Soft switchingTo configure the Oscar interface screen delay Navigating the Oscar InterfaceSingle-click, Enter Alt+OEnter BackspaceConfiguring Oscar Interface Menus To access the Oscar interface Setup dialog boxTo access the Oscar interface Names dialog box Assigning target device namesNames Dialog Box To assign names to target devices To list target devices alphabetically by nameTo assign a device type To access the Oscar interface Devices dialog boxAssigning device types To access the Oscar interface Menu dialog box Changing the display behaviorTo set a Screen Delay Time for the Oscar interface To choose the display order of target devicesOscar Interface Status Flags FlagDescription To access the Oscar interface Flag dialog boxControlling the status flag Broadcasting to target devices To determine how the status flag is displayedTo access the Oscar interface Broadcast dialog box To broadcast to selected target devicesTo add target devices to the Scan list Using Scan modeTo turn Broadcasting off To start the Scan mode To remove a target device from the Scan listTo cancel Scan mode 12 Commands Dialog BoxTo set the Screen Saver options Setting local port Screen Saver optionsTo access the Oscar interface Screen Saver dialog box To immediately turn on the screen saver Setting the keyboard country codeTo exit Screen Saver mode and log in to the local port To set the keyboard country code for Sun servers 14 Keyboard Dialog BoxManaging Server Tasks Using the Oscar Interface To access the Oscar interface Commands dialog boxTo disconnect a user Viewing and disconnecting user connectionsTo view current user connections Resetting your PS/2 keyboard and mouse To reset the PS/2 mouse and keyboard valuesDisplaying version information To display version informationClick X to close the Dsriq Version dialog box DSR Switch Installer/User Guide Remote Operations To log in to the DSR web serverAbout the DSR Explorer Window DSR Explorer Window Area Descriptions Letter DescriptionBookmarking a window Internet Explorer only Using the side navigation barUsing the top option bar Logging Out Printing a windowRefreshing a window To bookmark a windowUpgrading Dsriq modules Launching a KVM sessionDSR web server device management Managing Local Accounts Rebooting the applianceUser access levels Preemption levelsViewing and changing appliance configuration information Managing Device PropertiesAppliance Appliance Settings Versions Power Controlling Target Devices DSR Switch Installer/User Guide Video Viewer About the Video Viewer WindowSession time-out To enable/disable or configure the session time-outVideo Viewer minimum requirements Window Features CDE F G aVideo Viewer Window Descriptions Letter Changing the toolbarTo specify a toolbar hide time To change the Video Viewer window resolution Setting the Window SizeAdjusting the View To align the mouse cursorsTo enable automatic, full or manual scaling Adjusting color depthTo enable or disable full screen mode To refresh the screenAdditional Video Adjustment To manually adjust the video quality of the windowC D E F G H Block noise threshold and pixel noise threshold Contrast and brightnessDetection thresholds Cursor Type Adjusting Mouse OptionsAutomatic video adjustment Refresh imageTo select a key for exiting single cursor mode Single cursor modeTo enter single cursor mode Remote Cursor Local CursorScaling To exit single cursor modeTo change the mouse cursor setting AlignmentTo realign the mouse Using Keyboard Pass-throughUsing Macros To specify keyboard pass-throughTo capture the Video Viewer window to a file Saving the ViewClosing a Video Viewer Window Session To capture the Video Viewer window to your clipboardConsole Menu Network ConfigurationTo configure network settings using the Console menu Console Main Menu Terminal Operations To rename a user in the DSR switch database Security ConfigurationTo add a user to the DSR switch database Other Console Main Menu OptionsReset Certificates To remove a user from the DSR switch databaseReset Appliance Enable Debug MessagesRestore Factory Defaults Firmware ManagementAppendix a Flash Upgrades To upgrade the DSR switch firmware using the DSView softwareDSR Switch Installer/User Guide To resolve an issue Appendix B Technical SupportAppendix C Using DSView Software Over a Modem Connection Before you beginAppendix D Using DSRIQ-SRL Modules DSRIQ-SRL module modesIs Ctrl-F8 To create a macro To configure a DSRIQ-SRL moduleCreating a DSRIQ-SRL module macro Table D.1 DSRIQ-SRL Module Pinouts To use History modeHost Signal Signal Flow SRL Signal Pin Name/Description Table E.1 UTP Wiring Standards Pin Appendix E UTP CablingCabling installation, maintenance and safety tips Appendix F Technical Specifications Power Supply Table F.1 DSR Switch Product Specifications SPC Device PortDimensions USB Device PortAppendix G Sun Advanced Key Emulation DSR Switch Installer/User Guide Index NumericsModule 6, 7, 8, 9, 10, 43, 69, 73 Mode 74, 75 PPP Screen Saver Secure Mode Sessions User Connections