To connect the VERSAstreamVS-1028 Multi-link Series aggregator/regenerator, refer to Figure 24 and follow these steps:

1.Two power supplies are provided. Use of the second power supply is strongly recommended to assure uninterrupted monitoring. Connect both power supply barrel connectors into the power 1 and 2 ports, respectively, of the VERSA- stream. Plug the power supplies into the external power source, furthermore, connecting the second power supply to a different external power source circuit than the first power supply eliminates power as a single point of failure. The POWER 1 and 2 LEDs illuminate indicating POWER 1 and 2, respectively, are on. Either LED not illuminated indicates a defective power source and immediate replacement is required to insure redundant power integrity.

2.Connect network cables to the VERSAstreamNETWORK RJ45 ports. The NETWORK RJ45 Link LED is solid green indicating link has been established between the respective NETWORK port and network device. The LED Display Code table deciphers the RJ45 jacks with integrated LEDs that display line status and line speed of each port. The LED is flashing green when data is passed from the respective network device to the network port.

LED Display Code

Code

Link Data

Left LED

Solid Green

Flashing Green

WITH LINK OR DATA

Right LED

Green

Orange

OFF

Code

1,000 Mbs

100Mbs

10Mbs

3.Connect analysis devices to the VERSAstreamMONITOR ports. Two DRL494–2m cables are provided to connect analysis SC ports to the MONITOR duplex-LC ports. The LED associated with each duplex-LC jack indicates when light signal has been detected on the respective Rx MONITOR port.

NOTE: For other typical application installations of VERSAstreamMulti-link aggre- gator/regenerator series models, some NETWORK ports are duplex-LC jacks with associated LEDs that indicate when light signal has been detected on the respective Rx NETWORK port. And some MONITOR ports are RJ45 jacks with inte- grated LEDs that display line status and line speed of each port as deciphered in the The LED Display Code table. The LED is flashing green when data is passed from the respective MONITOR device to the MONITOR port.

SPAN and Multi-Link Aggregators/Regenerators • USERguide

Image 35
Contents USERguide Datacom Systems IncPage Proprietary Notice Copyright License Agreement Trademark AttributionCertifications Compliance TestingContents What Shipped ? Monitor more network traffic with fewer tools IntroductionSINGLEstream SS-200 Series Overview Attributes & AdvantagesSS-200 Features & Benefits Single stream SS-200 SpecificationsPower The Power LED illuminates indicating power is on SS-200 Connectivity Diagram SS-200 Application & Hardware InstallationSpan and Multi-Link Aggregators/Regenerators USERguide VERSAstream Span Series Overview VERSAstream Span Series Features & Benefits VERSAstream VERSAstream Span Series SpecificationsVERSAstream Span Hardware Description through VS-1022BT-BT Front Panel and functional diagramVS-1041LX-LX Front Panel and functional diagram VS-1082 Front Panel and functional diagram LED Display Code ‘Dual-Homed’ Server Application shown in , focus Application & Hardware Installation FigureFull Duplex aggregated Application shown in Figure Primary/Redundant Router Application shown in Figure VS-1022BT-BT Hardware InstallationLED Display Code VERSAstream Multi-link Series Overview Features and Benefits VERSAstream VERSAstream Multi-link Series SpecificationsVERSAstream Multi-link Hardware Description Figure VS-1026BT-BT Front Panel and functional diagramVS-1046 Front Panel and functional diagram VS-1610 Front Panel 1 of 2 in kit and functional diagram Analyzing/Monitoring Gigabit EtherChannel VS-1028 Gigabit EtherChannel Application Gigabit Ether Channel Application shown in FigureLED Display Code VS-1028 with Taps Application VS-1028 with Taps Application shown in , focusesLED Display Code VS-1028 Span and In-Line Application VS-1028 Span and In-line Application shown in FigureLED Display Code VS1610 kit Typical Application and functional diagram LED Display Code Span and Multi-Link Aggregators/Regenerators USERguide Limitation On Liability Customer ServiceWorld Wide Web Warranty Span and Multi-Link Aggregators/Regenerators USERguide Page By Datacom Systems Inc. All Rights Reserved