CyberPower Systems CPS1500AVR user manual Replacing the Battery, To Replace the Battery

Page 14

REPLACING THE BATTERY

CAUTION! Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery.

Service the battery under the supervision of personnel knowledgeable of batteries and their precautions.

CAUTION! Use only the specified type of battery. See your dealer for replacement batteries. CAUTION! The battery may present the risk of electrical shock. Do not dispose of batteries in a fire, as it may explode. Follow all local ordinances regarding proper disposal of batteries.

CAUTION! Do not open or mutilate the batteries. Release electrolyte is harmful to the skin and eyes and may be toxic.

CAUTION! A battery can present a high risk of short circuit current an electrical shock. Take the following precautions before replacing the battery:

1.Remove all watches, rings or other metal objects.

2.Only use tools with insulated handles.

3.DO NOT lay tools or other metal parts on top of battery or any battery terminals.

4.Wear rubber gloves and boots.

5.Determine if the battery is inadvertently grounded. If inadvertently grounded, remove source of ground. CONTACT WITH A GROUNDED BATTERY CAN RESULT IN ELECTRICAL SHOCK! The likelihood of such shock will be reduced if such grounds are removed during installation and maintenance (applicable to a UPS and a remote battery supply not having a grounded circuit).

TO REPLACE THE BATTERY

1.Remove the right-side of the faceplate.

2.Disconnect the black and red cable.

3.Remove the 4 retaining screws.

4.Pull battery pack from unit.

5.Slide the new battery pack into the unit.

6.Replace the 4 retaining screws.

7.Connect the black and red cable.

8.Replace the cover.

12

Image 14 Contents
Additional Installation Tips can be Found AT Table of Contents CPS1500AVR Inspection HOW to Determine the Power Requirements of Your EquipmentHardware Installation Guide Software Installation Information Powerpanel Plustm Software Installation Guide For Windows 95/98/MeFor Windows For Windows NTPowerPanel PlusTM Main Menu Powerpanel Plustm Main Window Description Powerpanel Plustm Setup WindowPowerpanel Plustm Advanced Setup Powerpanel Plustm Schedule MenuFor Windows 95/98/ME Powerpaneltm Installation GuidePowerpanel Plustm LOG Menu For Windows NT Testing Your UPS System Replacing the Battery To Replace the BatteryDefinitions for LED Indicators AVRTroubleshooting SpecificationsRegistration Limited Warranty Power Control Guarantee Limitation may not apply to you Mailsales@cyberpowersystems.com