Figure 3-13. Diagnostics Dialog Box
As each test is finished, a pass (green circle) or fail (red x) symbol displays to the left of each item as that test finishes. The following table details each of the tests.
Table 3-4. Diagnostic Test Details
Test | Description |
|
|
Firmware CRCs | Reports on the condition of the main board RAM |
Remote User Video | Reports on whether a digital video connection has been made to a digital device |
Indicates the total number of currently connected and powered SIP modules | |
Offline SIP modules | Indicates the number of SIP modules that were connected successfully in the |
| past and are turned off |
Suspect SIP modules | Indicates the number of SIP modules that were detected, but are either |
| unavailable for connection or dropped packets during the ping tests |
|
|
To run diagnostic tests:
1If the OSCAR® interface is not open, press <Print Screen>. The Main dialog box will appear.
2Click Commands - Run Diagnostics. A warning message displays indicating that all users will be disconnected.
3Click OK to begin diagnostics. or
Click X or press <Escape> to exit the dialog box without running a diagnostic test.
4All users are disconnected and the Diagnostics dialog box displays.
5As each test is finished, a pass (green circle) or fail (red x) symbol displays. The test is complete when the last test’s symbol displays.