2.SETTINGS
2.1Switch Panel Settings
Communication parameters are set with the switches in the switch panel. Unfasten two screws to access the switches. Note that it is not necessary to turn off the
1 | 2 | 3 | 4 | 5 6 7 | 8 |
ON
Data Rate
64K
56K
: Factory setting
Figure 3 Switch panel
2.1.1 Data rate
Set the data rate according to land line/network. The default setting is 64k (64 Kbps). 56k is for USA ISDN circuit, for example. Data rate cannot be change after connecting with a subscriber.
2.1.2 DIP switches
Table 1 DIP switch functions
SW No. | Function | OFF | ON | |
|
|
|
| |
SW1 | Automatic call | Direct call | Address call | |
|
|
|
| |
SW2 | Terminal interface | |||
|
|
|
| |
SW3 | Automatic data | NO | YES | |
rate switching | ||||
|
|
| ||
|
|
|
| |
SW4 | Command format | HDLC | BSC | |
|
|
|
| |
SW5 | Character format | 8 bit/no parity | 7 bit/odd parity | |
|
|
|
| |
SW6 | Not used |
|
| |
|
|
|
| |
SW7 | Not used |
|
| |
|
|
|
| |
SW8 | Not used |
|
| |
|
|
|
|
SW1: Automatic call mode
OFF: Call starts with reception of DTR signal from HSD terminal.
ON: Call starts when subscriber number from the HSD terminal is loaded on the TxD line.
3