2.4 Registering, Deleting Subscriber Number

2.4.1 Registering subscriber number

Register subscriber number as follows with the No.1 telephone. The subscriber number may contain 20 digits (*, # cannot be registered). The number can be confirmed by printing the status display.

1.Pick up the handset of the No.1 telephone and confirm dial tone.

2.Dial subscriber’s no. as follows:

* 5 1 * a a a 0 0 b b x x x x x x x x x #

Subscriber’s Number

Country Code

Automatic Dialing

Land Earth Station (LES)

Prefix (64k) for HSD call

3. Confirm dial tone (See table 2).

2.4.2 Deleting subscriber number

1. Dial * 5 1 * #.

2.4.3 Confirming subscriber number

HSD communications settings (HSD settings input to the communcation unit) are con- tained on the status monitor which can be printed from the No.1 telephone.

1.Pick up the handset of the No. 1 telephone.

2.Dial * 9 6 # to print the status monitor.

.

.

.

Prefix Code:

HSD Destination: XXXXXXXXXXXXXXX

2.4.4 Status display on the terminal unit

The status display shows HSD state. You can print it from the terminal unit. Sample HSD status indications are as below.

RX Signal Level (HSD) ...

RX IF AGC Level (HSD) ...

2nd Local (HSD) ...

6

Image 16
Contents Page B . N o . O M E 5 6 0 9 Safety Instructions Safety Information for the OperatorSafety Information for the Installer Electrical Shock HazardTable of Contents Appendix Usage Tips Declaration of conformity to typeFeatures IntroductionInstallation Materials CP16-01601 Installation Materials CP16-01602Equipment List Complete SetInstallation Materials CP16-01605 Installation Materials CP16-01603Optional Equipment System Configuration IB-181IB-281 IB-681Control Description OverviewFront panel Rear panel IB-681, rear view Settings Switch Panel Settings DIP switches Data rateSW2 Terminal interface OID/DID and IMN Settings Terminal Unit SettingsRegistering, Deleting Subscriber Number Registering subscriber numberDeleting subscriber number Confirming subscriber numberCalling OperationAutomatic HSD call Tone Name Frequency Manual callInterval Receiving Automatic call mode and receiving operationSW1 State Remarks V.25bis Command, Indication Receiving and automatic data rate switchingCommand Name Description SW3 State RemarksCommand Description Indication DescriptionDirect call setup sequence Call SequenceAddress call setup sequence Address call setup sequenceManual call setup sequence Manual call setup sequenceAutomatic call clear sequence Call clear sequence from landManual call clear sequence Manual call clear sequenceMaintenance & Troubleshooting MaintenanceCleaning Resetting the circuit breakerTroubleshooting for the User ThenGeneral CallingInstallation Mounting procedureMounting Mounting locationWiring Wiring between HSD modem and routerModifying the RF Conv board in the communication unit RS-449 InterfaceAntenna cable Position of R135 Length CPU2 Board 16P0133RF Conv Board RF Conv Board CPU2 BoardR135 J10Mounting of connector assy Rear Panel Board Sub 9 pinGround Wiring between HSD modem and communication unitJ11 Circuit delay Propagation delayRouter setting for network connection Communication with other makes of Inmarsat-B terminalsNetwork configuration Syuchronous -asynchronous adapter Land Earth Station IOR Etilat IB-681 Page Page Page Index