B&B Electronics manual Manual Document# 3PXCC4A3001

Page 24

Click on View (top of screen).

Click on Resources by type.

Double-click on Input/Output. Find an unused address to set your B&B Electronics serial card to.

Scroll through the list, check 03F8H, 02F8H, 03E8H, 02E8H. If one of these is available, use it. If not, check alternates.

Find a free address in the list. Most desktop PC’s have a COM1 and possibly a COM2 already on their system, which will be seen in the list. You may have to start at COM3 or COM4 to start your addressing of the ISA card you have. If these addresses are used you may have to resort to the Frequently Unused Port Addresses (found in Chapter 4, Table 3) of this manual. Write these open addresses and IRQ’s down for later reference.

22

Manual Document# 3PXCC4A3001

B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 B&B Electronics Ltd – Westlink Comm. Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445

Image 24
Contents Model 3PXCC4A Table of Contents Features Introduction and General InformationSpecifications Quick Installation Guide Use ESD precautions for safe handlingManual Document# 3PXCC4A3001 Manual Document# 3PXCC4A3001 Manual Document# 3PXCC4A3001 Manual Document# 3PXCC4A3001 Adding Serial Ports in Windows 95/98 Manual Document# 3PXCC4A3001 Manual Document# 3PXCC4A3001 Manual Document# 3PXCC4A3001 Manual Document# 3PXCC4A3001 Changing COM Port Resources in Windows 95/98 Manual Document# 3PXCC4A3001 Manual Document# 3PXCC4A3001 Manual Document# 3PXCC4A3001 Manual Document# 3PXCC4A3001 Adding Serial Ports in Windows NT Checking Windows 2000 for Available Address/IRQ’s Click on Hardware Click on Device Manager Manual Document# 3PXCC4A3001 Manual Document# 3PXCC4A3001 Adding Serial Ports in Windows Click Next Click on Add/Troubleshoot a device Manual Document# 3PXCC4A3001 Manual Document# 3PXCC4A3001 Manual Document# 3PXCC4A3001 Manual Document# 3PXCC4A3001 Manual Document# 3PXCC4A3001 Address and IRQ Setting Address Switch Setup Silk Screen Plot of 3PXCC4A PCB Switch Settings Standard Port AddressesBase Hex Address Binary EquivalentInterrupt Jumper Setup Standard IRQ SettingsSpace Description Shared IRQ Mode Communication Jumper Settings RS-232 ModeRS-422 Mode RS-485 Mode RS-485 OperationHigh Speed Mode RS-422 and RS-485 TerminationPhysical Hook-up and Troubleshooting PinoutsRJ45 Pin RS-422 Signal RS-422 PinoutsRS-422/RS-485 Four Wire Pinout Description Communication Cable DataTroubleshooting International/USA OfficeEuropean Office Appendix a Hardware I/O Map 3BC-3BE Appendix B Declaration of Conformity Statement Declaration of Conformity