Chapter 5: Communication Jumper Settings
This chapter will cover all of the jumper settings to set your B&B Serial Card for the proper communications that you desire.
CAUTION: Electrostatic Sensitive Device.
Use ESD precautions for safe handling.
RS-232 Mode
To configure Port A for
1.The four jumpers of JP7 - must be set to the "232" (upper) position.
2.The third jumper of JP8 must be set to the "232" (left) position.
The remaining jumpers of JP8 have no meaning in
RS-422 Mode
To configure Port A for
1.The four jumpers of JP7 must be set to the "422" (lower) position.
2.The top three jumpers of JP8 should be set to the 422 (right) position. The bottom jumper of JP8 switches the 120 Ω receiver termination resistor in or out. Typically this resistor should not be used. In some cases using high baud rates and very long cables, termination should be used.
Note that the EIA
36 | Manual Document# 3PXCC4A3001 |
B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph