RS-422 and RS-485 Termination

A 120Ω termination resistor has been provided for the RS- 422/485 receivers. To enable the termination provided, the termination jumper should be placed in the Rt IN position (left). If you do not need to use termination, place the jumper in the Rt OUT position (right). Termination should only be used when very long cable runs are used with high baud rates. For example, with most cables which are 4000 feet or shorter and have baud rates at 19.2K baud or lower, termination is not required. Note that if the termination is enabled (IN), the biasing of the RS-485 network is altered and the value of the bias resistors will likely need to be changed somewhere on the network. More information on termination and biasing can be found in B&B Electronics’ free RS- 422/RS-485 Application Note.

High Speed Mode

High data rates can be obtained with the 3PXCC4A cards by adjusting JP16B and JP17B. This multiplies the clock speed supplied to the UARTs by 4 times to 7.328MHz for all ports, allowing data rates up to 460.8K baud in RS-422 and RS-485 modes. Note that RS-232 does not support these extended baud rates.

To enable the X4 clock, simply move the shorting jumper from JP16B (*1) to JP17B (*4). This jumper is shipped from the factory in the standard clock (*1) position.

Note that serial software is not aware of the change in oscillator frequency. For example, in the × 4 position, setting the baud rate to 57.6K baud in software will result in a actual baud rate of 230.4K baud. It is important to note that increasing the baud rate may not increase actual throughput. In heavy multitasking cases or with a slow computer, the computer’s inability to respond to interrupts quickly enough will cause large idle spaces between characters. Increasing the baud rate to this point will not increase actual throughput.

38

Manual Document# 3PXCC4A3001

B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 B&B Electronics Ltd – Westlink Comm. Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445

Image 40
Contents Model 3PXCC4A Table of Contents Features Introduction and General InformationSpecifications Quick Installation Guide Use ESD precautions for safe handlingManual Document# 3PXCC4A3001 Manual Document# 3PXCC4A3001 Manual Document# 3PXCC4A3001 Manual Document# 3PXCC4A3001 Adding Serial Ports in Windows 95/98 Manual Document# 3PXCC4A3001 Manual Document# 3PXCC4A3001 Manual Document# 3PXCC4A3001 Manual Document# 3PXCC4A3001 Changing COM Port Resources in Windows 95/98 Manual Document# 3PXCC4A3001 Manual Document# 3PXCC4A3001 Manual Document# 3PXCC4A3001 Manual Document# 3PXCC4A3001 Adding Serial Ports in Windows NT Checking Windows 2000 for Available Address/IRQ’s Click on Hardware Click on Device Manager Manual Document# 3PXCC4A3001 Manual Document# 3PXCC4A3001 Adding Serial Ports in Windows Click Next Click on Add/Troubleshoot a device Manual Document# 3PXCC4A3001 Manual Document# 3PXCC4A3001 Manual Document# 3PXCC4A3001 Manual Document# 3PXCC4A3001 Manual Document# 3PXCC4A3001 Address and IRQ Setting Address Switch Setup Silk Screen Plot of 3PXCC4A PCB Switch Settings Standard Port AddressesBase Hex Address Binary EquivalentStandard IRQ Settings Interrupt Jumper SetupSpace Description Shared IRQ Mode RS-232 Mode Communication Jumper SettingsRS-422 Mode RS-485 Mode RS-485 OperationHigh Speed Mode RS-422 and RS-485 TerminationPhysical Hook-up and Troubleshooting PinoutsRJ45 Pin RS-422 Signal RS-422 PinoutsRS-422/RS-485 Four Wire Pinout Description Communication Cable DataInternational/USA Office TroubleshootingEuropean Office Appendix a Hardware I/O Map 3BC-3BE Appendix B Declaration of Conformity Statement Declaration of Conformity