B&B Electronics Zlinx 485 manual Types and Characteristics, Digital Inputs

Page 14

Hardware

Figure 11. DIN Clip with Spring on a Zlinx 485 Module

I/O Options and Characteristics

I/O Options

The Zlinx 485 family of products features a variety of input and output options. Base and expansion module options include:

2 analog inputs, 2 analog outputs, 2 digital inputs and 2 digital outputs (sourcing or sinking driver)

4 digital inputs and 4 digital outputs (sourcing or sinking driver)

8 digital inputs

8 digital outputs (sourcing or sinking driver)

o8 relay output model available

4 analog inputs

oRTD Temperature input module available

4 analog outputs

2 analog inputs and 2 analog outputs

(Modules continue to be developed with additional features and options.)

Refer to Appendix E for a list of available models and options.

I/O Types and Characteristics

Digital Inputs

DI’s can detect the presence of contact closures, transistor switches or on/off DC voltage signals (low or high logic levels). Voltages below 0.8 VDC are interpreted as a low state. Voltages between 4.0 VDC and 48 VDC are interpreted as a high state.

DI’s are also programmable to be NPN or PNP

Manual Documentation Number: Zlinx485m-1808 www.bb-elec.comwww.bb-europe.com

Image 14
Contents Zlinx Zlinx International HeadquartersTable of Contents Support Zlinx Product Family IntroductionAbout this Manual Features Package ChecklistHardware Zlinx 485 ModulesBase Modules Expansion ModulesProgramming the Base Module using the RS232 connector Base and Expansion Modules Connected TogetherConnectors Indicators, Connectors and AccessoriesLED Indicators Power Supply Connector RS-422/485 Connector Local Bus Connector LocationRS-422/485 Four-Wire Mode RS-422/485 Two-Wire ModePower Supply Requirements RS-232 ConnectionTypes and Characteristics Digital InputsAnalog Inputs DI WiringDigital Outputs Analog OutputsDo Wiring AI Wiring RTD Wiring Relay Wiring Type Modbus Memory Address Zlinx 485 Modes of Operation Peer-to-Peer ModeModbus Mode Connecting the Hardware Zlinx Base Module 2 wire RS-485 Connections Zlinx 485 Installation Getting StartedConnecting Zlinx 485 to a PC If the device is found, the Zlinx 485 Manager window opens Information Tab Zlinx 485 ManagerConfiguration Tab Input/Output TabConfiguration & Operation Configuring ZlinxTesting Modbus Mode Operation Peer-to-Peer Mode Settings Peer-to-Peer Master ConfigurationInput/Output Settings Digital Input Configuration Analog Input Configuration Saving the Configuration Firmware Updater Caution Dialog Box Updating Zlinx 485 FirmwareModbus Basics Modbus Help Modbus ASCII/RTU BasicsHints and Tips Appendix a Product Specifications Frequency Input Accuracy @ 25ºC Appendix B Dimensional Diagrams Dimensional Diagram of a Zlinx 485 Base ModuleAppendix C Serial Connections RS-232 PinoutsRS-422/485 4 Wire Pinouts Serial Connections Appendix D Modbus I/O Assignments Discrete Digital OutputsModbus I/O Assignments Modbus I/O Assignments Appendix E Zlinx 485 Models and Features Zlinx 485 Base Modules Model Number Module TypeAppendix F Zlinx 485 Troubleshooting Problem CausesAppendix G Terms and Definitions Term Definition