Avocent PM IPDU manual Appendix a Specifications

Page 47

37

APPENDICES

Appendix A: Specifications

Table A.1: PM IPDU Specifications

 

Input

Max Output

Max Output

Operating

 

 

 

 

Unit

Voltage

Current

Each Outlet

Temp

Weight

Width

Depth

Height

 

 

 

 

 

 

 

 

 

 

PM10-15A

100-125 VAC

15A (12A)

15A

(12A)

10-50 ºC

3.64 kg

17 in

8 in

1.75 in

 

 

 

 

 

 

 

 

 

 

PM10-20A,

100-125 VAC

20A (16A)

15A

(12A)

10-50 ºC

3.64 kg

17 in

8 in

1.75 in

PM10-L20A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PM10-L30A

100-125 VAC

30A (24A)

15A

(12A)

10-50 ºC

3.64 kg

17 in

8 in

1.75 in

 

 

 

 

 

 

 

 

 

 

PM10i-10A

100-240 VAC

10A

10A

 

10-50 ºC

3.64 kg

17 in

8 in

1.75 in

 

 

 

 

 

 

 

 

 

 

PM10i-15A

100-240 VAC

15A (12A)

10A

(8A)

10-50 ºC

3.64 kg

17 in

8 in

1.75 in

 

 

 

 

 

 

 

 

 

 

PM10i-16A

100-240 VAC

16A

10A

 

10-50 ºC

3.64 kg

17 in

8 in

1.75 in

 

 

 

 

 

 

 

 

 

 

PM10i-20A

100-240 VAC

20A (16A)

10A

(8A)

10-50 ºC

3.64 kg

17 in

8 in

1.75 in

 

 

 

 

 

 

 

 

 

 

PM10i-32A,

100-240 VAC

32A

10A

 

0-50 ºC

5.45 kg

17 in

11.5 in

1.75 in

PM10i-32Au

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PM10i-L30A

100-240 VAC

30A (24A)

10A

(8A)

0-50 ºC

5.45 kg

17 in

11.5 in

1.75 in

 

 

 

 

 

 

 

 

 

 

PM20-20A,

100-125 VAC

20A (16A)

15A

(12A)

10-50 ºC

7.73 kg

1.8 in

2.2 in

66 in

PM20-L20A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PM20-L30A

100-125 VAC

30A (24A)

15A

(12A)

10-50 ºC

7.73 kg

1.8 in

2.2 in

66 in

 

 

 

 

 

 

 

 

 

 

PM20i-16A

100-240 VAC

16A

10A

 

0-50 ºC

7.73 kg

2 in

2.8 in

66 in

 

 

 

 

 

 

 

 

 

 

PM20i-20A,

100-240 VAC

20A (16A)

10A

(8A)

0-50 ºC

7.73 kg

2 in

2.8 in

66 in

PM20i-L20A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PM20i-L30A

100-240 VAC

30A (24A)

10A

(8A)

0-50 ºC

7.73 kg

2 in

2.8 in

66 in

 

 

 

 

 

 

 

 

 

 

PM20i-32A

100-240 VAC

32A

10A

 

10-50 ºC

7.73 kg

2 in

2.8 in

66 in

 

 

 

 

 

 

 

 

 

 

Image 47
Contents Cyclades P M Ipdu Canadian DOC Notice FCC Warning StatementCyclades PM Ipdu Power On Table of Contents Appendices List of Figures Viii Cyclades PM Ipdu Installer/Administrator/User Guide List of Tables Cyclades PM Ipdu Installer/Administrator/User Guide Support for daisy chaining Features and BenefitsAlarms and monitoring Sequential power applicationIntegration with Avocent management products Hardware Configuration OptionsStandalone configuration Integrated configuration Daisy chained configurationCyclades PM Ipdu Installer/Administrator/User Guide Supplied with the PM Ipdu Modular input power cables for the PM IpduGetting Started Optional outlet cable package Rack Mounting the PM IpduTo mount the PM10 Ipdu or PM10i Ipdu Installation environmentDaisy Chaining PM IPDUs To access the console Accessing the ConsoleDirect console access Console access through a management deviceInitial configuration using the command prompt Configuring the PM IpduDefault configuration parameters Upgrading the PM Ipdu firmware Resetting the admin passwordTo upgrade PM Ipdu firmware Number of PM IPDUs Daisy chained PM IPDUs in the login promptPM Ipdu User Interface Logging in to the PM IpduArguments Commands AdduserAlarm SyntaxAssign Current BuzzerCurrentprotection Example CurrsegCycle Deluser DbsyncDisplay Exit Help FactorydefaultsHwocp HumidityTurns overcurrent protection off normal operation Interval Name ListLock Off Passwd RebootArguments Examples RestoreSave Syslog StatusTemperature Unlock UnassignVer UpgradeVoltage Whoami Cyclades PM Ipdu Installer/Administrator/User Guide Appendix a Specifications Interface Pinouts Sicherheitsanweisungen Appendix B Safety InstructionsSafety Instructions Istruzioni di Sicurezza Instrucciones de seguridad Instruções de SegurançaInstructions de sécurités PM10i Ipdu Appendix C Circuit BreakersPM Ipdu Units with One Circuit Breaker PM10i-L30A Ipdu PM20-L30A Ipdu PM10i-32A Ipdu and PM10i-32Au IpduPM20i-L30A Ipdu PM20i-32A Ipdu and PM20i-32Au Ipdu Circuit breaker trip time Appendix D Technical Support To resolve an issueCyclades PM Ipdu Installer/Administrator/User Guide Page 590-667-501B

PM IPDU specifications

Avocent PM IPDU (Intelligent Power Distribution Unit) is a cutting-edge solution designed for efficient power management and monitoring in data centers and IT environments. These devices are essential for businesses aiming to optimize power consumption, enhance uptime, and improve overall operational efficiency.

One of the primary features of the Avocent PM IPDU is its ability to provide real-time monitoring of power usage at the outlet level. This granularity allows IT professionals to track the power consumption of individual devices and make informed decisions regarding resource allocation and load balancing. The device supports multiple power distribution configurations, making it versatile enough to suit a variety of setups.

Incorporating advanced technologies, the Avocent PM IPDU supports intelligent alerts and notifications, enabling proactive management of potential power-related issues. Users can configure customizable thresholds for power consumption, and the system will automatically send alerts if these thresholds are breached. This proactive approach helps in minimizing downtime and averting potential outages.

Another notable characteristic is the comprehensive remote management capabilities of the Avocent PM IPDU. Users can access the unit's management interface via a web-based portal, which provides intuitive dashboards displaying real-time data on power usage, temperature, and environmental conditions. This remote access feature is essential for IT teams managing distributed environments or multi-site operations, as it facilitates quick and effective responses to power concerns.

The Avocent PM IPDU also integrates seamlessly with existing management systems, offering compatibility with various standards and protocols. This interoperability ensures that organizations can leverage their current infrastructure while enhancing their power management capabilities. Additionally, the unit supports power metering and reporting features, enabling detailed analysis of energy consumption trends over time.

Furthermore, Avocent PM IPDU models come equipped with features such as outlet-level control, allowing IT administrators to perform remote power cycling, thus increasing operational efficiency and reducing the need for on-site visits. The units are designed with robust security features, including customizable user permissions and encryption protocols, ensuring that power management operations are protected from unauthorized access.

Overall, the Avocent PM IPDU is an essential tool for organizations striving to improve their power management practices. With its advanced monitoring, remote management capabilities, and robust security features, it is well-suited for modern data center environments where efficiency, reliability, and operational effectiveness are paramount.