Avocent ACS 6000 CLI Commands and Configuration Guide

Page 17

Chapter 1: Introduction, Navigation and Commands

7

 

 

: or

() : group

CLI Command Set

NOTE: Most of the commands work from any location when the path to the command parameter is included.

NOTE: The word “node” refers to an entity such as a route, host or user, which can be added, configured or deleted.

help

Generate a help message about how to navigate the CLI.

Syntax:

--:- units cli-> help

- Thank you for using the cli -

This interface allows you to easily modify configurations to customize and define the functionality of your unit.

Press <tab> <tab> to see the list of available commands.

Please refer to the Reference Guide for a description of commands, special keys and additional information on how to use this interface.

Some basic and useful keys are:

up/down arrow - navigates up/down in the command history tab (once/twice) - shows the next possible option(s)

Other hints:

Use backslash '\' to escape spaces, '\' and other control characters when assigning values to parameters.

add

Add a node.

Image 17
Contents Cyclades ACS Canadian DOC Notice Safety and EMC Approvals and MarkingsFCC Warning Statement Cyclades ACS 6000 Advanced Console Server Power On Table of Contents Port Access and Configuration Examples Appendices Page List of Tables Page Introduction, Navigation and Commands Serial Port To start the CLI Access Options and How to Log Into the CLIConfiguration Tasks Performed With the CLI CLI Navigation Units cli-cd appliancesettingsAutocompletion Command only help, pwd Command Line SyntaxParameters Syntax usedHelp CLI Command SetAdd Add a nodeDelete Sniff PwdConnect Disconnect ShareExit/quit FtpSet ScpCommit RevertCycle, on, off, lock and unlock Powercycle, poweroff and poweronShow/ls Examples PasswdOpiepasswd Listuser Special Multi-session CommandsKilluser SendmsgUnits cli -cleandbuf overview/appliancedatalogging CleandbufWiz Units cli -inspectdbuf overview/appliancedataloggingEnter set enableipv6=no to disable IPv6 Enter show to view the status of IPv6 configurationEnter set enableipv6=yes to enable IPv6 Enter show to verify the changeEnter commit Page Port Access and Configuration Tasks Where Performed Port Access and Configuration ExamplesFor Serial Port For PowerTopology Parameters Field Description For Appliance Topology Parameters Field Description For Outlets Port Access and Configuration ExamplesTo connect to a device console connected to a serial port Topology cli-connect 77-77-70-p-2 passwordConnect to a Device Console Connected to a Serial Port To set up a console access service CAS port Manage Power for a Device Connected to an Outlet on a PDUPort Configuration Examples Enter show to view the configuration of port To enable a power management portEnter cd portsettings to configure port Portsettings cli-set portsettings/ serialprofile=casEnter show to verify the configuration Page Enter show to view the appliancesettings options To view and access appliancesettings optionsEnter show to view the available options ApplianceSettings/GlobalSettingsUnits cli-cd appliancesettings/globalsettings Global Settings Options Global Settings Navigation TreeEnter show to view the list of available options ApplianceSettings/NetworkUnits cli-cd appliancesettings/network Network Options Network Navigation TreeNetwork Options Network Navigation Tree CLI Appliance Settings Options Enter show to view the changes To configure a IPv4 or IPv6 static IP addressSettings cli-set ipv4method=static IPv6Hosts Enter show to view the current host settingsTo add a host to the host table Type add then press ReturnHosts cli-cd 172.26.31.164/settings Wiz commandCLI Appliance Settings Options Ports Options Ports Navigation Tree ApplianceSettings/PortsUnits cli-cd appliancesettings/ports Enter show. a listing similar to the following appears To enable and assign the Serial profile to a serial portTo configure port profiles To enable and configure the AUX/Modem portUnits cli-cd appliancesettings/ports/casprofile Enter showApplianceSettings/Security ApplianceSettings/Pluggable DevicesUnits cli-cd appliancesettings/pluggabledevices Units cli-cd appliancesettings/securityAuthentication Options Authentication Navigation Tree ApplianceSettings/AuthenticationUnits cli-cd appliancesettings/authentication To add a user and password ApplianceSettings/UsersUnits cli-cd appliancesettings/users Users Options Users Navigation TreeApplianceSettings/EventNotification ApplianceSettings/SyslogApplianceSettings/Firewall Enter show to verify that the new user has been addedUnits cli-cd appliancesettings/ipsecvpn ApplianceSettings/IPSecVPNFirewall Options Firewall Navigation Tree 10 IPSecVPN Options IPSecVPN Navigation Tree11 Snmp Options Snmp Navigation Tree ApplianceSettings/SNMPUnits cli-cd appliancesettings/snmp 12 Date and Time Options DateAndTime Navigation Tree ApplianceSettings/Date and TimeUnits cli-cd appliancesettings/dateandtime Units cli-cd appliancesettings/bootconfiguration ApplianceSettings/Boot ConfigurationSave your settings ApplianceSettings/Online HelpTo set the online help URL Line similar to the following appearsPage Overview Options To view and perform configuration with the Overview optionsPress Tab Tab to display the options Ports Menu Options Level Use this option toOverview Commands Description or Field Enter show to view the Information optionsInformation Options To view and perform Information optionsInformation Options Description Information Options Description To view and kill ActiveSessions Active Sessions InformationFrom the units level CLI prompt, enter cd activesessions Units cli-cd activesessions --activesessionscliTo rename a PDU Power Management OptionsTo manage power for a selected outlet Enter shell. a warning appears followed by the root prompt Connect to the console of the console server as rootAppendix B Technical Support To resolve an issueIndex Page Page 590-770-501B
Related manuals
Manual 73 pages 13.68 Kb

ACS 6000 specifications

The Avocent ACS 6000 is a leading edge solution designed for remote access and management of critical IT infrastructure. This compact and robust device serves as a key tool for IT administrators, allowing them to manage serial console access for servers, networking equipment, and other serially controlled devices. Ideal for both enterprise environments and smaller settings, the ACS 6000 enhances operational efficiency and reliability.

One of the standout features of the Avocent ACS 6000 is its ability to provide secure remote access. The device supports various security protocols, including SSH, SSL, and IP filtering, ensuring that access to the managed devices is protected against unauthorized entry. With strong encryption standards, it provides peace of mind for organizations handling sensitive data.

The ACS 6000 is equipped with advanced management capabilities, enabling administrators to monitor and control serial communications across multiple devices from a single interface. This centralized management not only reduces the complexity associated with handling numerous individual devices, but it also streamlines troubleshooting and system diagnostics, resulting in quicker response times and less downtime.

Another notable characteristic of the ACS 6000 is its scalability. The modular design allows for easy expansion as organizational needs evolve. IT managers can begin with a basic configuration and upgrade seamlessly by adding more ports or features as necessary. This flexibility makes the ACS 6000 an ideal solution for growing organizations.

User-friendly features such as an intuitive web interface simplify the setup and configuration process. Through this interface, users can easily navigate and utilize various functions, including alert settings, logging, and reporting features that provide valuable insights into device performance and usage patterns.

In addition to its robust functionality, the ACS 6000 is designed with reliability in mind. Built to endure varied environmental conditions, it operates reliably in data centers and remote locations alike. The device can also handle high-voltage operations, making it versatile for various industrial applications.

In summary, the Avocent ACS 6000 stands out as an essential tool for modern IT management, delivering secure, scalable, and user-friendly solutions for remote access to serial controlled devices. With its advanced features and robust design, it effectively meets the challenges of IT infrastructure management in today's fast-paced digital landscape.