Avocent ACS 6000 manual CLI Equivalent Actions to Web Manager Checkbox Selection

Page 26

16Cyclades ACS 6000 Advanced Console Server Command Reference Guide

CLI Equivalent Actions to Web Manager Checkbox Selection

NOTE: The following example procedure, which configures IPv6, illustrates the actions to use in the CLI to enable or disable an option when a checkbox would be selected or deselected in the Web Manager.

To configure IPv6 (example of how to perform the equivalent of Web Manager checkbox selection/deselection):

1.Log into the CLI and enter cd appliance_settings/network/ip.

--:- units cli->cd appliance_settings/network/ipv6

2.Enter show to view the status of IPv6 configuration.

--:- ipv6 cli-> show IPv6

[X]enable_IPv6

[ ] get_dns_from_dhcpv6

[ ] get_domain_from_dhcpv6

NOTE: At this location, you can use '=' to change the value or '/' to select a parameter inside the section.

3.Type set enable_ipv6= and press Tab to view the options for the parameter.

--:- ipv6 cli-> set enable_ipv6=<Tab> no yes

4.Type set enable_ipv6: and press Tab to view the child parameters.

--:- ipv6 cli-> set enable_ipv6/<Tab>

get_dns_from_dhcpv6= get_domain_from_dhcpv6=

5.Enter set enable_ipv6=no to disable IPv6.

--:- ipv6 cli->set enable_ipv6=no

-or-

Enter set enable_ipv6=yes to enable IPv6.

--:- ipv6 cli->set enable_ipv6=yes

6.(Optional) Enter either of the following commands to enable subparameters.

**:- ipv6 cli->set enable_ipv6/ get_dns_from_dhcpv6=yes

**:- ipv6 cli->set enable_ipv6/ get_domain_from_dhcpv6=yes

7.Enter show to verify the change.

**:- ipv6 cli-> show ipv6

[X]enable_ipv6

[X]get_dns_from_dhcpv6

Image 26
Contents Cyclades ACS Canadian DOC Notice Safety and EMC Approvals and MarkingsFCC Warning Statement Cyclades ACS 6000 Advanced Console Server Power On Table of Contents Port Access and Configuration Examples Appendices Page List of Tables Page Introduction, Navigation and Commands Serial Port To start the CLI Access Options and How to Log Into the CLIConfiguration Tasks Performed With the CLI Units cli-cd appliancesettings CLI NavigationAutocompletion Parameters Command Line SyntaxCommand only help, pwd Syntax usedAdd CLI Command SetHelp Add a nodeDelete Sniff PwdConnect Exit/quit ShareDisconnect FtpCommit ScpSet RevertCycle, on, off, lock and unlock Powercycle, poweroff and poweronShow/ls Examples PasswdOpiepasswd Killuser Special Multi-session CommandsListuser SendmsgWiz CleandbufUnits cli -cleandbuf overview/appliancedatalogging Units cli -inspectdbuf overview/appliancedataloggingEnter set enableipv6=yes to enable IPv6 Enter show to view the status of IPv6 configurationEnter set enableipv6=no to disable IPv6 Enter show to verify the changeEnter commit Page Port Access and Configuration Examples Port Access and Configuration Tasks Where PerformedFor Serial Port For PowerTopology Parameters Field Description For Appliance Port Access and Configuration Examples Topology Parameters Field Description For OutletsTo connect to a device console connected to a serial port Topology cli-connect 77-77-70-p-2 passwordConnect to a Device Console Connected to a Serial Port To set up a console access service CAS port Manage Power for a Device Connected to an Outlet on a PDUPort Configuration Examples Enter cd portsettings to configure port To enable a power management portEnter show to view the configuration of port Portsettings cli-set portsettings/ serialprofile=casEnter show to verify the configuration Page To view and access appliancesettings options Enter show to view the appliancesettings optionsUnits cli-cd appliancesettings/globalsettings ApplianceSettings/GlobalSettingsEnter show to view the available options Global Settings Options Global Settings Navigation TreeUnits cli-cd appliancesettings/network ApplianceSettings/NetworkEnter show to view the list of available options Network Options Network Navigation TreeNetwork Options Network Navigation Tree CLI Appliance Settings Options Settings cli-set ipv4method=static To configure a IPv4 or IPv6 static IP addressEnter show to view the changes IPv6To add a host to the host table Enter show to view the current host settingsHosts Type add then press ReturnWiz command Hosts cli-cd 172.26.31.164/settingsCLI Appliance Settings Options Ports Options Ports Navigation Tree ApplianceSettings/PortsUnits cli-cd appliancesettings/ports To enable and assign the Serial profile to a serial port Enter show. a listing similar to the following appearsUnits cli-cd appliancesettings/ports/casprofile To enable and configure the AUX/Modem portTo configure port profiles Enter showUnits cli-cd appliancesettings/pluggabledevices ApplianceSettings/Pluggable DevicesApplianceSettings/Security Units cli-cd appliancesettings/securityAuthentication Options Authentication Navigation Tree ApplianceSettings/AuthenticationUnits cli-cd appliancesettings/authentication Units cli-cd appliancesettings/users ApplianceSettings/UsersTo add a user and password Users Options Users Navigation TreeApplianceSettings/Firewall ApplianceSettings/SyslogApplianceSettings/EventNotification Enter show to verify that the new user has been addedFirewall Options Firewall Navigation Tree ApplianceSettings/IPSecVPNUnits cli-cd appliancesettings/ipsecvpn 10 IPSecVPN Options IPSecVPN Navigation Tree11 Snmp Options Snmp Navigation Tree ApplianceSettings/SNMPUnits cli-cd appliancesettings/snmp 12 Date and Time Options DateAndTime Navigation Tree ApplianceSettings/Date and TimeUnits cli-cd appliancesettings/dateandtime ApplianceSettings/Boot Configuration Units cli-cd appliancesettings/bootconfigurationTo set the online help URL ApplianceSettings/Online HelpSave your settings Line similar to the following appearsPage Press Tab Tab to display the options To view and perform configuration with the Overview optionsOverview Options Ports Menu Options Level Use this option toInformation Options Enter show to view the Information optionsOverview Commands Description or Field To view and perform Information optionsInformation Options Description Information Options Description From the units level CLI prompt, enter cd activesessions Active Sessions InformationTo view and kill ActiveSessions Units cli-cd activesessions --activesessionscliTo rename a PDU Power Management OptionsTo manage power for a selected outlet Connect to the console of the console server as root Enter shell. a warning appears followed by the root promptTo resolve an issue Appendix B Technical SupportIndex Page Page 590-770-501B
Related manuals
Manual 73 pages 13.68 Kb

ACS 6000 specifications

The Avocent ACS 6000 is a leading edge solution designed for remote access and management of critical IT infrastructure. This compact and robust device serves as a key tool for IT administrators, allowing them to manage serial console access for servers, networking equipment, and other serially controlled devices. Ideal for both enterprise environments and smaller settings, the ACS 6000 enhances operational efficiency and reliability.

One of the standout features of the Avocent ACS 6000 is its ability to provide secure remote access. The device supports various security protocols, including SSH, SSL, and IP filtering, ensuring that access to the managed devices is protected against unauthorized entry. With strong encryption standards, it provides peace of mind for organizations handling sensitive data.

The ACS 6000 is equipped with advanced management capabilities, enabling administrators to monitor and control serial communications across multiple devices from a single interface. This centralized management not only reduces the complexity associated with handling numerous individual devices, but it also streamlines troubleshooting and system diagnostics, resulting in quicker response times and less downtime.

Another notable characteristic of the ACS 6000 is its scalability. The modular design allows for easy expansion as organizational needs evolve. IT managers can begin with a basic configuration and upgrade seamlessly by adding more ports or features as necessary. This flexibility makes the ACS 6000 an ideal solution for growing organizations.

User-friendly features such as an intuitive web interface simplify the setup and configuration process. Through this interface, users can easily navigate and utilize various functions, including alert settings, logging, and reporting features that provide valuable insights into device performance and usage patterns.

In addition to its robust functionality, the ACS 6000 is designed with reliability in mind. Built to endure varied environmental conditions, it operates reliably in data centers and remote locations alike. The device can also handle high-voltage operations, making it versatile for various industrial applications.

In summary, the Avocent ACS 6000 stands out as an essential tool for modern IT management, delivering secure, scalable, and user-friendly solutions for remote access to serial controlled devices. With its advanced features and robust design, it effectively meets the challenges of IT infrastructure management in today's fast-paced digital landscape.