Avocent ACS 6000 To enable a power management port, Enter show to view the configuration of port

Page 34

24Cyclades ACS 6000 Advanced Console Server Command Reference Guide

8.Enter set port_settings/serial_profile=cas then enter commit as shown to assign the CAS profile and save the settings.

--:- port_settings cli->set port_settings/ serial_profile=cas

**:- port_settings cli-> commit

--:- port_settings cli->

9.Enter set port_settings/status=enabled, then enter commit and show as shown to enable the configured port, save the settings and verify the configuration.

--:- port_settings cli->set port_settings/ status=enabled

**:- port_settings cli-> commit

--:- port_settings cli-> show

To enable a power management port:

1.Log onto the CLI as an administrator and enter cd appliance_settings/ports/physical_ports/

<port_name> to select a port with a PDU connected (port 3 is used as an example).

--:- Units cli->cd appliance_settings/ports/physical_ports/ serial_ports/3

2.Enter show to view the configuration of port 3.

--:- 3 cli-> show 3

port_settings/ --:-3 cli->

3.Enter cd port_settings to configure port 3.

--:- 3 cli->cd port_settings

4.Type set then press Tab Tab to view the configuration options.

--:- port_settings cli-> set <Tab><Tab> communication_settings port_settings

5.Enter show to view the configuration of port 3.

--:-port_settings cli-> show port_settings

port: 3

status = disabled

rj45_pin-out = cyclades serial_profile = unconfigured

communication_settings speed = 9600 parity = None data_bits = 8 stop_bits = 1 flow_control = none

Image 34
Contents Cyclades ACS FCC Warning Statement Safety and EMC Approvals and MarkingsCanadian DOC Notice Cyclades ACS 6000 Advanced Console Server Power On Table of Contents Port Access and Configuration Examples Appendices Page List of Tables Page Introduction, Navigation and Commands Serial Port Configuration Tasks Performed With the CLI Access Options and How to Log Into the CLITo start the CLI Units cli-cd appliancesettings CLI NavigationAutocompletion Parameters Command Line SyntaxCommand only help, pwd Syntax usedAdd CLI Command SetHelp Add a nodeDelete Connect PwdSniff Exit/quit ShareDisconnect FtpCommit ScpSet RevertShow/ls Powercycle, poweroff and poweronCycle, on, off, lock and unlock Opiepasswd PasswdExamples Killuser Special Multi-session CommandsListuser SendmsgWiz CleandbufUnits cli -cleandbuf overview/appliancedatalogging Units cli -inspectdbuf overview/appliancedataloggingEnter set enableipv6=yes to enable IPv6 Enter show to view the status of IPv6 configurationEnter set enableipv6=no to disable IPv6 Enter show to verify the changeEnter commit Page Port Access and Configuration Examples Port Access and Configuration Tasks Where PerformedTopology Parameters Field Description For Appliance For PowerFor Serial Port Port Access and Configuration Examples Topology Parameters Field Description For OutletsConnect to a Device Console Connected to a Serial Port Topology cli-connect 77-77-70-p-2 passwordTo connect to a device console connected to a serial port Port Configuration Examples Manage Power for a Device Connected to an Outlet on a PDUTo set up a console access service CAS port Enter cd portsettings to configure port To enable a power management portEnter show to view the configuration of port Portsettings cli-set portsettings/ serialprofile=casEnter show to verify the configuration Page To view and access appliancesettings options Enter show to view the appliancesettings optionsUnits cli-cd appliancesettings/globalsettings ApplianceSettings/GlobalSettingsEnter show to view the available options Global Settings Options Global Settings Navigation TreeUnits cli-cd appliancesettings/network ApplianceSettings/NetworkEnter show to view the list of available options Network Options Network Navigation TreeNetwork Options Network Navigation Tree CLI Appliance Settings Options Settings cli-set ipv4method=static To configure a IPv4 or IPv6 static IP addressEnter show to view the changes IPv6To add a host to the host table Enter show to view the current host settingsHosts Type add then press ReturnWiz command Hosts cli-cd 172.26.31.164/settingsCLI Appliance Settings Options Units cli-cd appliancesettings/ports ApplianceSettings/PortsPorts Options Ports Navigation Tree To enable and assign the Serial profile to a serial port Enter show. a listing similar to the following appearsUnits cli-cd appliancesettings/ports/casprofile To enable and configure the AUX/Modem portTo configure port profiles Enter showUnits cli-cd appliancesettings/pluggabledevices ApplianceSettings/Pluggable DevicesApplianceSettings/Security Units cli-cd appliancesettings/securityUnits cli-cd appliancesettings/authentication ApplianceSettings/AuthenticationAuthentication Options Authentication Navigation Tree Units cli-cd appliancesettings/users ApplianceSettings/UsersTo add a user and password Users Options Users Navigation TreeApplianceSettings/Firewall ApplianceSettings/SyslogApplianceSettings/EventNotification Enter show to verify that the new user has been addedFirewall Options Firewall Navigation Tree ApplianceSettings/IPSecVPNUnits cli-cd appliancesettings/ipsecvpn 10 IPSecVPN Options IPSecVPN Navigation TreeUnits cli-cd appliancesettings/snmp ApplianceSettings/SNMP11 Snmp Options Snmp Navigation Tree Units cli-cd appliancesettings/dateandtime ApplianceSettings/Date and Time12 Date and Time Options DateAndTime Navigation Tree ApplianceSettings/Boot Configuration Units cli-cd appliancesettings/bootconfigurationTo set the online help URL ApplianceSettings/Online HelpSave your settings Line similar to the following appearsPage Press Tab Tab to display the options To view and perform configuration with the Overview optionsOverview Options Ports Menu Options Level Use this option toInformation Options Enter show to view the Information optionsOverview Commands Description or Field To view and perform Information optionsInformation Options Description Information Options Description From the units level CLI prompt, enter cd activesessions Active Sessions InformationTo view and kill ActiveSessions Units cli-cd activesessions --activesessionscliTo manage power for a selected outlet Power Management OptionsTo rename a PDU Connect to the console of the console server as root Enter shell. a warning appears followed by the root promptTo resolve an issue Appendix B Technical SupportIndex Page Page 590-770-501B
Related manuals
Manual 73 pages 13.68 Kb

ACS 6000 specifications

The Avocent ACS 6000 is a leading edge solution designed for remote access and management of critical IT infrastructure. This compact and robust device serves as a key tool for IT administrators, allowing them to manage serial console access for servers, networking equipment, and other serially controlled devices. Ideal for both enterprise environments and smaller settings, the ACS 6000 enhances operational efficiency and reliability.

One of the standout features of the Avocent ACS 6000 is its ability to provide secure remote access. The device supports various security protocols, including SSH, SSL, and IP filtering, ensuring that access to the managed devices is protected against unauthorized entry. With strong encryption standards, it provides peace of mind for organizations handling sensitive data.

The ACS 6000 is equipped with advanced management capabilities, enabling administrators to monitor and control serial communications across multiple devices from a single interface. This centralized management not only reduces the complexity associated with handling numerous individual devices, but it also streamlines troubleshooting and system diagnostics, resulting in quicker response times and less downtime.

Another notable characteristic of the ACS 6000 is its scalability. The modular design allows for easy expansion as organizational needs evolve. IT managers can begin with a basic configuration and upgrade seamlessly by adding more ports or features as necessary. This flexibility makes the ACS 6000 an ideal solution for growing organizations.

User-friendly features such as an intuitive web interface simplify the setup and configuration process. Through this interface, users can easily navigate and utilize various functions, including alert settings, logging, and reporting features that provide valuable insights into device performance and usage patterns.

In addition to its robust functionality, the ACS 6000 is designed with reliability in mind. Built to endure varied environmental conditions, it operates reliably in data centers and remote locations alike. The device can also handle high-voltage operations, making it versatile for various industrial applications.

In summary, the Avocent ACS 6000 stands out as an essential tool for modern IT management, delivering secure, scalable, and user-friendly solutions for remote access to serial controlled devices. With its advanced features and robust design, it effectively meets the challenges of IT infrastructure management in today's fast-paced digital landscape.