1.Condensate trap Ð A 2-in. condensate trap must be ®eld supplied.

2.Ductwork Ð Secure down¯ow discharge ductwork to roof curb. For horizontal discharge applications, attach ductwork to unit with ¯anges.

3.To convert a unit to down¯ow discharge Ð Units are equipped with factory-installed inserts in the down¯ow openings. Remove the inserts similar to removing an electri- cal knock-out. Use an accessory duct cover to seal the hori- zontal discharge openings in the unit. Units installed in horizontal discharge orientation do not require duct covers.

4.Air¯ow Ð Units are draw-thru in the Cooling mode and blow-thru in the Heating mode.

5.Maximum cooling air¯ow Ð To minimize the possibility of condensate blow-off from the evaporator, air¯ow through the units should not exceed 450 cfm/ton.

6.Minimum cooling air¯ow Ð The minimum cooling air¯ow is 350 cfm/ton.

7.Minimum ambient operating temperature Ð All standard units have a minimum ambient operating temperature of 40 F. With accessory low ambient temperature kit, units can operate at temperatures down to 0° F.

19

Image 19
Contents Efficient Operation FEATURE/BENEFITSUnit 583A DURABLE, Dependable ComponentsTable of Contents ARI* Capacities Cooling Capacities and Efficiencies Model Number NomenclatureHeating Capacities and Efficiencies Unit Heating Input Output Capacity Temperature RiseRange F Unit Size 583A Physical DataFACTORY-INSTALLED Options Options and AccessoriesFIELD-INSTALLED Accessories Options and Accessories Economizer Characteristics Base Unit Dimensions Ð Unit Sizes``A 042060/090 Unit Part Number Accessory DimensionsCurb Select Unit That Corresponds to Power Source Available Selection Procedure with ExampleII Select Unit Based on Required Cooling Capacity SHC Performance Data NET Cooling CapacitiesPerformance Data NET Cooling Capacities 583A--048 Performance Data Unit 583A Pressure Drop 583A WET Coil Pressure DropOutdoor Sound ONE-THIRD Octave Band Data Ð Decibels Unit Size Airflow Pressure DropNUMBER² High Altitude CompensationNatural GAS only Input Output OrificeTypical Piping and Wiring Application Data Electrical Data OFM Typical Wiring Schematic Ð 208/230-1-60 ShownIGC Typical Wiring Schematic Ð 208/230-3-60 ShownTypical Wiring Schematic Ð 460-3-60 Shown Operating Sequence ControlsPart 1 Ð General Guide SpecificationsPart 2 Ð Products Guide Specifications Page Copyright 1999 Bryant Heating & Cooling Systems
Related manuals
Manual 8 pages 4.13 Kb

583A specifications

The Bryant 583A is a cutting-edge gas furnace designed for both efficiency and comfort, making it an ideal heating solution for residential applications. This model is particularly known for its exceptional performance and innovative technology, resulting in lower energy bills and a more consistent indoor environment.

One of the standout features of the Bryant 583A is its high-efficiency operation, boasting an AFUE (Annual Fuel Utilization Efficiency) rating of up to 95%. This means that a significant portion of the fuel consumed is converted into usable heat, making it an environmentally friendly choice that reduces energy waste. The design employs a two-stage heating operation, which allows the furnace to adjust its output according to the heating demands of the home, providing balanced warmth while minimizing energy consumption.

Built with advanced technology, the Bryant 583A includes a variable-speed blower motor that enhances comfort by distributing heated air more evenly throughout the home. This feature not only improves air circulation but also promotes quieter operation compared to standard single-speed blowers. The intelligent control system of the furnace permits compatibility with smart thermostats, which further enhances energy efficiency and user convenience.

Another notable characteristic of the Bryant 583A is its durability. Constructed with high-quality materials, this furnace is designed to withstand the rigors of continuous operation and to provide reliable service throughout its lifespan. Additionally, it features a heavy-duty heat exchanger that ensures optimal heat transfer while reducing the risk of breakdowns.

The Bryant 583A also prioritizes safety with features such as an automatic shut-off, which activates in the event of a malfunction, protecting both the system and the home. Additionally, its compact design allows for easy installation in a variety of spaces, making it a versatile choice for different home layouts.

In summary, the Bryant 583A is a remarkable gas furnace that combines high-efficiency performance, cutting-edge technology, and reliability. With its two-stage heating operation, variable-speed blower motor, and robust safety features, it caters to homeowners seeking both comfort and cost savings during the colder months. As a trusted name in heating solutions, Bryant continues to lead the way in delivering products that enhance home comfort while prioritizing energy efficiency and durability.