Black Box 3600 MODEM manual Response Messages, Response Message Meaning

Page 234

Hardware Options

V.25 Response Messages

Response Message

Meaning

 

 

CFIAB

Call failure - answer back tone but no

 

connection

 

 

CFIDT

Call failure - no dial tone

 

 

CFIET

Call failure - reorder or busy

 

 

CFILD

Call failure - link list complete

 

 

CFINS

Call failure - number not stored

 

 

CFINT

Call failure - no answer back tone, no

 

ringback

 

 

CFIRT

Call failure - timeout occurred

 

 

CNX @ 33600 bps

Intermediate call progress - connection

 

made at 33600

 

 

CNX @ 31200 bps

Intermediate call progress - connection

 

made at 31200

 

 

CNX @ 28800 bps

Intermediate call progress - connection

 

made at 28800

 

 

CNX @ 26400 bps

Intermediate call progress - connection

 

made at 26400

 

 

CNX @ 24000 bps

Intermediate call progress - connection

 

made at 24000

 

 

CNX @ 21600 bps

Intermediate call progress - connection

 

made at 21600

 

 

CNX @ 19200 bps

Intermediate call progress - connection

 

made at 19200

 

 

CNX @ 16800 bps

Intermediate call progress - connection

 

made at 16800

 

 

CNX @ 14400 bps

Intermediate call progress - connection

 

made at 14400

 

 

CNX @ 12000 bps

Intermediate call progress - connection

 

made at 12000

 

 

CNX @ 9600 bps

Intermediate call progress - connection

 

made at 9600

 

 

E-26

Modem 3600

Image 234
Contents 3600 Trademarks $2334253/426 #$%&*+ #$%&,+ $$$ $$$$ $&% $$% $%%-% $&% % %&$ $ !+ #**# # 3! #41% #**# # 3! #41%&, +2 #4!# 3C $ 35 F + *&*A1 $ @ $A = 01BB Page $%% $ +,-*./0 1 **-*2**,3/0 Page Page Page Page #26 Page Page Page 555,5,65E##E%E% % Page #5 S7-# Chapter Introduction Shelf-Mount UnitsFeatures Data ModeCommunications Software Class 1 Fax Communications Software Fax ModeSoftware Internet BrowserDescription FunctionalPhysical Rear Panel 115 Vac Model Modem 3600 Card Card Version of the ModemChapter Installation Mounting AccessoriesDC Power Connection Electrical InstallationAC Power Connection DTE ConnectionDigital Interface Signals Pin Signal Description s Pin 232D Signal DescriptionPin Signal Descriptions DCETelephone Line Connection Dial Mode Pstn Connection Dial jack Dial-up Connection 115 Vac ModelLeased Line Connection TELSET/LEASED Line Jack Leased Line Connection 115 Vac Model Shelf-Mount MD1000C Installation MD1000C ConnectionsPower-Up Chapter Getting StartedOption Selection Dialing with a Standard Telephone Autodialing from a Terminal with the AT CommandsPlacing a Call Autodialing from Front PanelAnswering a Call Ending a CallReasons for Call Termination Reasons for Call Terminatio n ConditionReasons for Call Termination Condition Page Chapter Front Panel Operation LED DescriptionsLCD Menus LCD Menu OperationLCD Menu Option Selectio n RegLCD Menu Option Selection Main Menu Submenu Submenu Item Option Com RegSubmenu Main Menu Option Com Reg Lease line only † Dial line only Modify Change DTE Speed DTE=DCE Modify Change DTE Dial Method Async Modify Change DTE RTS/CTS Delay Password of 0000 disables front panel security Front Panel Security Front Panel Operation Chapter AT Commands Command CategoriesOperation Modes Sending Commands to the Modem Offline Command ModeOnline Command Mode Creating a Command Statement AT Autobaud Guidelines for Creating Command StatementsMonitor Display Command Statement BufferRepeating a Command a Backspace KeyResponse Commands Numbered CommandsGroup Commands Response Displays Q Command OperationDigit / Word Selection Negotiation Displays WCall Progress / Connect Speed Messages Command Code Set Number Operation Number Code Application *RCResponse Number Codes / Messages Code Message MeaningDTE rate 31200 bps Connect 300/V42 Connect 300/MNP5 Dial Commands Dialing DInsert Long Pause Tone Dialing TPulse Dialing P Wait for Second Dial Tone WHook Flash Switching to Answer Mode after Dialing RRemaining in Command Mode Wait for 5 Seconds of Silence @Autodial Number Location *AUn Switching from Voice to DataDialing a Stored Telephone Number Sn Voice CallsAutoanswer S0 AT Command Answer aManual Answer Caller ID *IDDistinctive Ring *DR Caller ID Message s Modem sends this messageTerminal Interface Commands Data Carrier Detect &CData Set Ready &S Data Terminal Ready &DSerial Port Ring Indicator Pin 22 \R Request to Send / Clear to Send &RDTE Controlled Fallback Rate Pin 23 *FB General CommandsChanging from Data Mode to Command Mode +++ Local Character Echo EOnline Character Echo F Hanging Up H, H1Fast Disconnect H2, H3 Speaker Volume L Eprom CheckSpeaker Control M Long Space Disconnect Y Asynchronous / Synchronous Mode Selection &MReturn Online O Bis Guard Tones &GMake / Break Dial Pulse Ratio &P Asymmetric Bit Rates *AS Synchronous Transmit Clock Source &XRate Selection Thresholds *TH Modulation *MMMaximum DCE Speed %B Minimum DCE Speed %L Auto Retrain %E Automatic Rate Adaption %RManual Rate Adaption *RR Product Revision Level %VTalk / Data *DA Online Quick Reference $HProduct Serial Number $V Fast Train *FTPrivate Line Operation Disable AT Command Set *NTWire Operation Dial Line Transmit Level *TDnWire Leased Line Operation Wire Dial-up OperationDial Backup Manual Dial Backup *LD Dial Backup *DBReturn to Leased Line from Dial Backup *LB Dial / Leased Line &LActive Profile Configuration CommandsConfiguration Profiles Stored ProfileStoring a Configuration &W Powerup Option Set &YReset to Stored Configuration Z Load Factory Options &FnView Configuration Profiles/Received Signal Options &V Storing a Telephone Command Line &Zx=n, *CNx,n, *NDRemote Configuration Soft Download Password %P1, $YRetaining / Restoring Options *RO Remote Configuration Security Remote Security Code %P=Entering Remote Configuration %T=, &T Enabling/Disabling Remote Configuration *RARemote Configuration DTE Speed *RB Remote Configuration Format *RFRemote Configuration Saving or Discarding Options *RQ Page Ccitt V.42 bis Error Control Protocol Reliable ModeChapter Protocols Constant Speed Interface Auto-Reliable ModeNormal Mode Data CompressionDirect Mode Protocol CommandsFlow Control Disconnect Buffer Delay %D Optional Detection Phase \M Serial Port DTE Constant Speed \JOperating Mode \N Auto-Reliable Fallback Character %AnSerial Port Flow Control \Q XON/XOFF Pass Through \X Data Link Flow Control \GBreak Control \Kn Inactivity Timer \T Maximum Reliable Block Size \A Transmit Break / Set Break Length \BSet Auto-Reliable Buffer \C 42bis Data Compression %C Chapter Test Mode Operation Diagnostic Test s Offline OnlineTest Categories Test Commands Operation Terminating a Test in Progress &TTesting the Local Modem Local Analog Loopback &T1Local Analog Loopback with Self Test &T8 Local Analog with Test PatternTesting the Remote Modem Local Digital Loopback &T3Grant/Deny RDL Request &T4, &T5 Remote Digital Loopback &T6Remote Digital Loopback with Self Test &T7 Test Pattern %TDTE Controlled Remote Digital Loopback Pin 21 *RD DTE Controlled Local Analog Loopback Pin 18 *LAChapter Security Autocallback SecurityOperating with Low Security Low Security OperationOperating without Low Security Remote OperationLocal Operation Low Security CommandsPasswords LCD Indication of SecurityHigh Security Security Levels Superuser Enabling High Security $EH=pw High Security CommandsDefault Passwords Disabling High Security $DSetting Passwords $Pn=pw$pw Set Security Levels $Ln=mSet User Callback Number $Cn=m Extended Features $W Display Extended Feature Status $W?Display / Reset Illegal Access Attempt Counters $M, $Mn, $M Security Status $E? Factory Reset $F=pw$pwRemoving a User $Rn Display User Status $S?Remote Logon Procedure $n=pw Local Logon Command $n=pwLocal Logoff Command $$ Verify User Information $In, $IBnSecurity Chapter Fax Operation Fax OperationFax Defaults Modem InitializationFax Autoanswer Fax Associated Options Class 1 DetailsStored Fax Profile Class 1 Commands Dial Command DAnswer Command a On Hook HOff Hook H1 Service Class Indication +FCLASS?Service Class Capabilities +FCLASS=? Class 0 Operation +FCLASS=0Receive Silence +FRS=Time Fax Transmit and Receive ModesValues for Fax Modulatio n Modulation Speed Facsimile Transmit +FTM=Mod Facsimile Receive +FRM=ModValues for Fax Modulation Speed Hdlc Transmit +FTH=Mod Hdlc Receive +FRH=ModTest Supported Range of Values +FTx=?, +FRx=? Binary File Transfer Class 1 Result Code +FCERRORCommand Description Fax Autoanswer +FAA=Chapter Status Registers RegistersChanging S-Register Values Register Operation Sn?, Sn? Changing Register Values Sn=v, Sn=vIndividual Bit Command Sn . # =v Ring Count S1Line-Feed Character S4 Escape Character S2End-of-Line Character S3 Backspace Character S5Lost Carrier Detect Time S10 Pause Interval for Comma S8Carrier Detect Time S9 Dtmf Tone Duration S11Bit Mapped S14 Bit Value Command DescriptionS13 S15S17 Test Timeout S18System Tests S16 S19Bit Mapped S21 Comman Bit Value DescriptionBit Mapped S22 Bit Mapped S23S24 DTR State Recognition S25 RTS/CTS Delay S26Lookback Timer S28 Bit Mapped S27Bit Mapped S30 Bit Value CommandBit Mapped S29 S31Bit Mapped S32 DTR / Dial Backup Number to Dial S35Remote Configuration Escape Character S41 S33XON Character from DTE S44 Remote Configuration Guard Time S42S43 Xoff Character from DTE S45Leased Line Transmit Level S52 Automatic Rate Adaption Threshold S53Flow Control S54 \Q3 Enable bilateral CTS/RTS flow controlDisable modem port flow control S55Inactivity Timer S58 Compression Control S56Bit Mapped S57 Break Control S59 101 \K5 Break optionDisable auto-reliable data buffer Enable auto retrainMNP compression enabled Bit Mapped S60Auto-Reliable Fallback Character S64 Disconnect Buffer Delay S62Maximum Transmit Block Size S63 S65-66Link Speed Status S67 S68DCE Independent Speed S69 10010 B18 33,600 bps\M1 Enable V.42 fast detect Operating Mode S70Operating Mode Status S71 111 \N7 Lapm or MNP or native auto ReliableBit Mapped S72 Password Timeout S73Callback Delay S74 Callback Retry S75Lockout Threshold S77 Callback Retry Delay S76Autocallback Timer S78 Break Length S79Serial Port or DTE Speed S80 Minimum DCE Speed S81 00001 DisabledEnable negotiation status Negotiation Status S82S85-S87 Enable any key abortBit Mapped S84 Modulation Type S88Current Modulation S91 S92 S94Bit Mapped S97 Settings S95Asymmetric Settings S96 S98- S100Chapter Bis Autodialer Autodialer Command Strings and Parameters Software GuidelinesInvalid Responses Bis Commands and Responses Dial ParametersParameters Function Dial Command CRN nn...n Program Number Command PRN ann...nCNX@nnnnnBPS Intermediate Call Progress ResponseDial Stored Number CRS a Sepacall progress messagesEtbsysystxLSNsp Request List of Stored Numbers RLNDisregard Incoming Call DIC LSNann...nsepann...nLink Number by Address PRL ab Connect Incoming Call CICRedial Last Number CRR n Seprcall progress messagesRequest List of Linked Numbers RLL EtbspspstxLSLsp Modem Options Command PRO xxxyy00Request List of Version RLV LSLalsepalModem 11-11 Save Current Settings PRK Restore Factory Settings PRP nRequest List of Stored Options RLO xxx yy V.25 Autodialer Options Definition Settings Default OptionsModem 11-15 Ebcdic Ascii Modem 11-17 Test Bilateral Commanded Loop Maintenance Chapter MaintenanceFuse Replacement GeneralCalling Technical Support Appendix a Specifications SizeModem Data Rates Modulation SpeedCarrier Detect Level Page Appendix B Phone Jack Descriptions Pin FunctionPage Appendix C Hardware Options Jumper Option SelectionFigure C-1. Cover Removal Figure C-2. Jumper Location for Ground Option Replacing the Cover Appendix D Fault Isolation Procedure Fault Isolation ProcedureModem and Telephone Line Check PartModem Page Appendix E Command Index and Defaults Command Reg DescriptionWait for 2nd dial tone S7 value Command Reg Description Restore factory configuration 1 † EBCDIC, NRZ1 Command Reg Description Command Reg Description Command Reg Description BER Command Reg Description DCE Switches modem to talk mode † Command Reg Description Command Reg Description Fax Command Description Command DescriptionValueModulationSpeed Command Description Low Security High Security†cannot be executed from remote configuration mode Modem Remote Configuration Commands Data bits, mark parity, 1 stop bit Default Reg Function Factory SetRO=Read only RW=Read or write Modem Default Bis Dialer Commands Synchronous Description CommandSynchronous Description Command Response Messages Response Message MeaningINC Asynchronous Dial-up with V.42 bis Protocol AT&F or AT&F1 Modem Options DCE rate 33600 Modulation automodeDial Line Options Tone dial Factory Option Set # Asynchronous Dial-up without V.42 bis Protocol AT&F2Factory Option Set #3 Synchronous 4-wire Leased Line AT&F4 Modem Options DCE rateAsynchronous 4-wire Leased Line withV.42bis Protocol AT&F5 Factory Option Set #5Factory Option Set # Synchronous 2-wire Leased Line Normal Originate AT&F7 Synchronous 2-wire Leased Line Forced Answer AT&F8 Factory Option Set #9 Synchronous V.25bis Dialer AT&F9Appendix F Ascii and Ebcdic Characters NUL ESC ET end of transmission ACK0 DEL Hardware Options Hardware Options Hardware Options Hardware Options Appendix G Abbreviations and Acronyms Abbreviations and Acronyms PBX Xmit Appendix H Flash Upgrade What You NeedTroubleshooting Service and Support Page Index Index-2V.3600 3600Index-3 Index-4V.3600 3600Index-5 Index-6V.3600 3600Index-7 Index Index-8V.3600