Black Box 3600 MODEM manual Modem

Page 207

Hardware Options

Part II

This part determines the performance of the local and remote modems and the telephone circuits. It also determines each modem's ability to receive a transmitted signal from the other site, properly equalize and decode the signal and then loop this regenerated signal into the transmitter for transmission back to the other modem. This test applies to both leased line and dial line operation.

1)Configure the local modem for REMOTE DIGITAL LOOP WITH TEST PATTERN. This signals the remote modem to go into digital loop. The remote modem receives and then retransmits the data back to the local mode. If the digital bilateral loop is enabled at the remote, the remote DTE is looped back to itself.

2)An alternative to the above procedure is to request the operator at the remote modem to configure his modem for LOCAL DIGITAL LOOP. Configure the local modem for TEST PATTERN. The remote modem receives and retransmits the data back to the local modem.

3)The TEST PATTERN ERRORS display will count received errors.

4)At the local modem, the indicators should be as follows:

5)To further test the modem and communications link, reverse the system loopback. First exit the existing loopback test. Reverse the roles of the local and remote modems and repeat step two.

Note

If the bilateral digital loop is enabled at the local modem, the DTE interface is looped to itself and permits the DTE to check the interface circuitry as well as itself.

Modem 3600

D-3

Image 207
Contents 3600 Trademarks $2334253/426 #$%&*+ #$%&,+ $$$ $$$$ $&% $$% $%%-% $&% % %&$ $ !+ #**# # 3! #41% #**# # 3! #41%&, +2 #4!# 3C $ 35 F + *&*A1 $ @ $A = 01BB Page $%% $ +,-*./0 1 **-*2**,3/0 Page Page Page Page #26 Page Page Page 555,5,65E##E%E% % Page #5 S7-# Shelf-Mount Units Chapter IntroductionData Mode FeaturesInternet Browser Fax ModeSoftware Communications Software Class 1 Fax Communications SoftwareDescription FunctionalPhysical Rear Panel 115 Vac Model Card Version of the Modem Modem 3600 CardMounting Accessories Chapter InstallationDTE Connection Electrical InstallationAC Power Connection DC Power ConnectionDigital Interface Signals Pin 232D Signal Description Pin Signal Description sDCE Pin Signal DescriptionsTelephone Line Connection Dial-up Connection 115 Vac Model Dial Mode Pstn Connection Dial jackLeased Line Connection TELSET/LEASED Line Jack Leased Line Connection 115 Vac Model MD1000C Connections Shelf-Mount MD1000C InstallationPower-Up Chapter Getting StartedOption Selection Autodialing from Front Panel Autodialing from a Terminal with the AT CommandsPlacing a Call Dialing with a Standard TelephoneEnding a Call Answering a CallReasons for Call Terminatio n Condition Reasons for Call TerminationReasons for Call Termination Condition Page LED Descriptions Chapter Front Panel OperationLCD Menu Operation LCD MenusReg LCD Menu Option Selectio nMain Menu Submenu Submenu Item Option Com Reg LCD Menu Option SelectionSubmenu Main Menu Option Com Reg Lease line only † Dial line only Modify Change DTE Speed DTE=DCE Modify Change DTE Dial Method Async Modify Change DTE RTS/CTS Delay Password of 0000 disables front panel security Front Panel Security Front Panel Operation Chapter AT Commands Command CategoriesOperation Modes Sending Commands to the Modem Offline Command ModeOnline Command Mode Autobaud Guidelines for Creating Command Statements Creating a Command Statement ATBackspace Key Command Statement BufferRepeating a Command a Monitor DisplayResponse Commands Numbered CommandsGroup Commands Negotiation Displays W Command OperationDigit / Word Selection Response Displays QCall Progress / Connect Speed Messages Number Code Application *RC Command Code Set Number OperationCode Message Meaning Response Number Codes / MessagesDTE rate 31200 bps Connect 300/V42 Connect 300/MNP5 Dialing D Dial CommandsWait for Second Dial Tone W Tone Dialing TPulse Dialing P Insert Long PauseWait for 5 Seconds of Silence @ Switching to Answer Mode after Dialing RRemaining in Command Mode Hook FlashVoice Calls Switching from Voice to DataDialing a Stored Telephone Number Sn Autodial Number Location *AUnCaller ID *ID AT Command Answer aManual Answer Autoanswer S0Caller ID Message s Modem sends this message Distinctive Ring *DRData Carrier Detect &C Terminal Interface CommandsData Terminal Ready &D Data Set Ready &SRequest to Send / Clear to Send &R Serial Port Ring Indicator Pin 22 \RLocal Character Echo E General CommandsChanging from Data Mode to Command Mode +++ DTE Controlled Fallback Rate Pin 23 *FBOnline Character Echo F Hanging Up H, H1Fast Disconnect H2, H3 Speaker Volume L Eprom CheckSpeaker Control M Bis Guard Tones &G Asynchronous / Synchronous Mode Selection &MReturn Online O Long Space Disconnect YMake / Break Dial Pulse Ratio &P Modulation *MM Synchronous Transmit Clock Source &XRate Selection Thresholds *TH Asymmetric Bit Rates *ASMaximum DCE Speed %B Minimum DCE Speed %L Automatic Rate Adaption %R Auto Retrain %EProduct Revision Level %V Manual Rate Adaption *RRFast Train *FT Online Quick Reference $HProduct Serial Number $V Talk / Data *DADial Line Transmit Level *TDn Disable AT Command Set *NTWire Operation Private Line OperationWire Dial-up Operation Wire Leased Line OperationDial Backup Dial / Leased Line &L Dial Backup *DBReturn to Leased Line from Dial Backup *LB Manual Dial Backup *LDStored Profile Configuration CommandsConfiguration Profiles Active ProfilePowerup Option Set &Y Storing a Configuration &WLoad Factory Options &Fn Reset to Stored Configuration ZStoring a Telephone Command Line &Zx=n, *CNx,n, *ND View Configuration Profiles/Received Signal Options &VRemote Configuration Soft Download Password %P1, $YRetaining / Restoring Options *RO Remote Security Code %P= Remote Configuration SecurityEnabling/Disabling Remote Configuration *RA Entering Remote Configuration %T=, &TRemote Configuration Format *RF Remote Configuration DTE Speed *RBRemote Configuration Saving or Discarding Options *RQ Page Ccitt V.42 bis Error Control Protocol Reliable ModeChapter Protocols Data Compression Auto-Reliable ModeNormal Mode Constant Speed InterfaceDirect Mode Protocol CommandsFlow Control Disconnect Buffer Delay %D Serial Port DTE Constant Speed \J Optional Detection Phase \MAuto-Reliable Fallback Character %An Operating Mode \NSerial Port Flow Control \Q Data Link Flow Control \G XON/XOFF Pass Through \XBreak Control \Kn Inactivity Timer \T Maximum Reliable Block Size \A Transmit Break / Set Break Length \BSet Auto-Reliable Buffer \C 42bis Data Compression %C Chapter Test Mode Operation Diagnostic Test s Offline OnlineTest Categories Terminating a Test in Progress &T Test Commands OperationLocal Analog Loopback &T1 Testing the Local ModemLocal Analog with Test Pattern Local Analog Loopback with Self Test &T8Local Digital Loopback &T3 Testing the Remote ModemRemote Digital Loopback &T6 Grant/Deny RDL Request &T4, &T5Test Pattern %T Remote Digital Loopback with Self Test &T7DTE Controlled Local Analog Loopback Pin 18 *LA DTE Controlled Remote Digital Loopback Pin 21 *RDAutocallback Security Chapter SecurityRemote Operation Low Security OperationOperating without Low Security Operating with Low SecurityLCD Indication of Security Low Security CommandsPasswords Local OperationHigh Security Security Levels Superuser Disabling High Security $D High Security CommandsDefault Passwords Enabling High Security $EH=pwSetting Passwords $Pn=pw$pw Set Security Levels $Ln=mSet User Callback Number $Cn=m Extended Features $W Display Extended Feature Status $W?Display / Reset Illegal Access Attempt Counters $M, $Mn, $M Display User Status $S? Factory Reset $F=pw$pwRemoving a User $Rn Security Status $E?Verify User Information $In, $IBn Local Logon Command $n=pwLocal Logoff Command $$ Remote Logon Procedure $n=pwSecurity Fax Operation Chapter Fax OperationFax Defaults Modem InitializationFax Autoanswer Fax Associated Options Class 1 DetailsStored Fax Profile Dial Command D Class 1 CommandsOn Hook H Answer Command aClass 0 Operation +FCLASS=0 Service Class Indication +FCLASS?Service Class Capabilities +FCLASS=? Off Hook H1Receive Silence +FRS=Time Fax Transmit and Receive ModesValues for Fax Modulatio n Modulation Speed Facsimile Transmit +FTM=Mod Facsimile Receive +FRM=ModValues for Fax Modulation Speed Hdlc Transmit +FTH=Mod Hdlc Receive +FRH=ModTest Supported Range of Values +FTx=?, +FRx=? Fax Autoanswer +FAA= Class 1 Result Code +FCERRORCommand Description Binary File TransferRegisters Chapter Status RegistersChanging S-Register Values Changing Register Values Sn=v, Sn=v Register Operation Sn?, Sn?Ring Count S1 Individual Bit Command Sn . # =vBackspace Character S5 Escape Character S2End-of-Line Character S3 Line-Feed Character S4Dtmf Tone Duration S11 Pause Interval for Comma S8Carrier Detect Time S9 Lost Carrier Detect Time S10S15 Bit Value Command DescriptionS13 Bit Mapped S14S19 Test Timeout S18System Tests S16 S17Comman Bit Value Description Bit Mapped S21Bit Mapped S22 Bit Mapped S23S24 Bit Mapped S27 RTS/CTS Delay S26Lookback Timer S28 DTR State Recognition S25S31 Bit Value CommandBit Mapped S29 Bit Mapped S30S33 DTR / Dial Backup Number to Dial S35Remote Configuration Escape Character S41 Bit Mapped S32Xoff Character from DTE S45 Remote Configuration Guard Time S42S43 XON Character from DTE S44Automatic Rate Adaption Threshold S53 Leased Line Transmit Level S52S55 \Q3 Enable bilateral CTS/RTS flow controlDisable modem port flow control Flow Control S54Inactivity Timer S58 Compression Control S56Bit Mapped S57 101 \K5 Break option Break Control S59Bit Mapped S60 Enable auto retrainMNP compression enabled Disable auto-reliable data bufferS65-66 Disconnect Buffer Delay S62Maximum Transmit Block Size S63 Auto-Reliable Fallback Character S64S68 Link Speed Status S6710010 B18 33,600 bps DCE Independent Speed S69111 \N7 Lapm or MNP or native auto Reliable Operating Mode S70Operating Mode Status S71 \M1 Enable V.42 fast detectCallback Retry S75 Password Timeout S73Callback Delay S74 Bit Mapped S72Break Length S79 Callback Retry Delay S76Autocallback Timer S78 Lockout Threshold S77Serial Port or DTE Speed S80 Negotiation Status S82 00001 DisabledEnable negotiation status Minimum DCE Speed S81Modulation Type S88 Enable any key abortBit Mapped S84 S85-S87S92 S94 Current Modulation S91S98- S100 Settings S95Asymmetric Settings S96 Bit Mapped S97Chapter Bis Autodialer Software Guidelines Autodialer Command Strings and ParametersInvalid Responses Bis Commands and Responses Dial ParametersParameters Function Program Number Command PRN ann...n Dial Command CRN nn...nSepacall progress messages Intermediate Call Progress ResponseDial Stored Number CRS a CNX@nnnnnBPSLSNann...nsepann...n Request List of Stored Numbers RLNDisregard Incoming Call DIC EtbsysystxLSNspSeprcall progress messages Connect Incoming Call CICRedial Last Number CRR n Link Number by Address PRL abRequest List of Linked Numbers RLL LSLalsepal Modem Options Command PRO xxxyy00Request List of Version RLV EtbspspstxLSLspModem 11-11 Restore Factory Settings PRP n Save Current Settings PRKRequest List of Stored Options RLO xxx yy Options V.25 Autodialer Options Definition Settings DefaultModem 11-15 Ebcdic Ascii Modem 11-17 Test Bilateral Commanded Loop General Chapter MaintenanceFuse Replacement MaintenanceCalling Technical Support Size Appendix a SpecificationsModulation Speed Modem Data RatesCarrier Detect Level Page Pin Function Appendix B Phone Jack DescriptionsPage Jumper Option Selection Appendix C Hardware OptionsFigure C-1. Cover Removal Figure C-2. Jumper Location for Ground Option Replacing the Cover Fault Isolation Procedure Appendix D Fault Isolation ProcedurePart Modem and Telephone Line CheckModem Page Command Reg Description Appendix E Command Index and DefaultsWait for 2nd dial tone S7 value Command Reg Description Restore factory configuration 1 † EBCDIC, NRZ1 Command Reg Description Command Reg Description Command Reg Description BER Command Reg Description DCE Switches modem to talk mode † Command Reg Description Command Reg Description Command Description Fax Command DescriptionValueModulationSpeed High Security Command Description Low Security†cannot be executed from remote configuration mode Modem Remote Configuration Commands Data bits, mark parity, 1 stop bit Reg Function Factory Set DefaultRO=Read only RW=Read or write Modem Default Synchronous Description Command Bis Dialer CommandsSynchronous Description Command Response Message Meaning Response MessagesINC Asynchronous Dial-up with V.42 bis Protocol AT&F or AT&F1 Modem Options DCE rate 33600 Modulation automodeDial Line Options Tone dial Asynchronous Dial-up without V.42 bis Protocol AT&F2 Factory Option Set #Factory Option Set #3 Modem Options DCE rate Synchronous 4-wire Leased Line AT&F4Factory Option Set #5 Asynchronous 4-wire Leased Line withV.42bis Protocol AT&F5Factory Option Set # Synchronous 2-wire Leased Line Normal Originate AT&F7 Synchronous 2-wire Leased Line Forced Answer AT&F8 Synchronous V.25bis Dialer AT&F9 Factory Option Set #9Appendix F Ascii and Ebcdic Characters NUL ESC ET end of transmission ACK0 DEL Hardware Options Hardware Options Hardware Options Hardware Options Appendix G Abbreviations and Acronyms Abbreviations and Acronyms PBX Xmit What You Need Appendix H Flash UpgradeTroubleshooting Service and Support Page Index Index-2V.3600 3600Index-3 Index-4V.3600 3600Index-5 Index-6V.3600 3600Index-7 Index Index-8V.3600