Multi-Link Voice/Fax/Modem Call Processor manual Input Power Requirements

Page 34

INPUT POWER REQUIREMENTS-

At AC Transformer:

110-125 Volts AC Only, 50-60 Hz

At Power Jack On Stick:

12-14Volts AC and DC

POWER CONSUMPTION-

6.2 Watts

CO INTERFACE-

 

Ringer Equivalence Number:

0.5 B

Input Ring Detection:

40-150 Volts AC, 15-68 Hz

DEVICE INTERFACE-

 

Battery:

-48 Volts Nominal DC To All Devices

Off-Hook Detection:

3-80 mA

Ring Generator Frequency:

30 Hz (+/- ..1)Hz Voltage Regulated

 

and Current Limited

Waveform:

True Sinusoidal

Ringing No Load:

Approx. 82.8 Volts RMS AC

Ringing 8000 Ohm Impedance (REN 1.0):

Approx. 8 1.6 Volts RMS AC

Ringing 4000

Ohm Impedance (REN 2.0): Approx. 73.0 Volts RMS AC

Ringing 2667

Ohm Impedance (REN 3.0):

Approx. 64.5 Volts RMS AC

Ringing

2000

Ohm Impedance (REN 4.0):

Approx. 55.0 Volts RMS AC

Ringing

1800

Ohm Impedance (REN 5.0):

Approx. 49.5 Volts RMS AC

29

Image 34
Contents Online Manual for This is not rocket science Safety Instructions Page Installation Instructions HOW Works Answering Machine Silent Transfer-This feature works like Do’s and Don’ts Of SAC Programming Standard Features No Programming Needed To grab a call from a pulse dial phone Page Stick Programming and Quick Reference Guide Initial Check Page Summary of the types of tones you will hear An Overview of Programming Audible Read Back of PROGRAMMING-BEEP Beep BEEP-BOOOOOOOP Executing Audible Read Back With The Stick FAX Machines and PC FAX Cards From The ...... And Here’s Another Curve Ball File Answering Machines Computer Modems Other Stuff That Works Where You Gonna Put It? Your Own Personal Secretary Feature Recommendations Pertinent To This Installation Simple PLUG-IN with Extensions and Total BARGE-IN Protection Installation C Installed Modular Installing the Stick on a Multiple Phone Line System Voice Page Sticken It To The Wall Input Power Requirements FCC Registration DOC Registration Limited Warranty MULTI-LINK INC