Multitech MTPSR1-202ST quick start Data Control, Ring

Page 14

ISDN ProxyServer Quick Start Guide

conveying Calling Party information to the terminal for ISDN voice calls. The CLI information is only included with the first RING message for a given incoming call, and appears as fol- lows:

RING

FM: 5552000 TO: 5551000

If the Calling Party Number information is not included in the incoming SETUP message, the RING message appears as follows:

RING TO: 5551000

If the Called Party Number information is not included in the incoming SETUP message, the RING message will appear as follows:

RING FM: 5552000

If neither the Called Party Number, nor the Calling Party Num- ber is included in the incoming SETUP message, the RING message will contain no additional information.

Auto Protocol Detection - Always Unchecked (Disabled)

Identifies that automatic protocol detection is enabled or dis- abled for an ISDN data call. The default setting is 0, which dis- ables the Auto-Protocol Detection function.

Auto Answer Data Calls _________ Rings to Answer____

Select Auto Answer if you want your ProxyServer to automati- cally answer all incoming data calls (this option does not affect the analog port). The Rings to Answer number, in the range of 1 to 255, selects the number of rings the ProxyServer waits before answering an incoming call. The default is one ring.

Data Control

Data Protocol_____________________________________

The data protocol, also known as the B-channel protocol and the rate adaption protocol, is the “language” that is spoken over each 64K bps channel between two ISDN devices. The devices on both ends of the ISDN link must use identical data protocols.

8

Image 14
Contents Isdn ProxyServer Page Quick Start Guide Page Contents Isdn ProxyServer Quick Start Guide Introduction Isdn ProxyServerRelated Documentation Safety Warnings Unpacking your ProxyServerCabling your ProxyServer Cable Connections Cabling Procedure Step Procedure Network Configuration Before You Start Loading your SoftwareCall Control Parameters  Voice SpidData Control Ring Dialing Method Loading your Software Page Page IP Port Configuration Page Isdn Isdn ProxyServer Quick Start Guide Page Limited Warranty Service82076801