Grandstream Networks, Inc.

the TFTP server is connected to the device’s LAN port, the firmware upgrade will not work by design.

7.2Configuration File Download

Grandstream SIP Device can be configured via Web Interface as well as via Configuration File through TFTP or HTTP. “Config Server Path” is the TFTP or HTTP server path for configuration file. It needs to be set to a valid URL, either in FQDN or IP address format. The “Config Server Path” can be same or different from the “Firmware Server Path”.

A configuration parameter is associated with each particular field in the web configuration page. A parameter consists of a Capital letter P and 2 to 3 (Could be extended to 4 in the future) digit numeric numbers. i.e., P2 is associated with “Admin Password” in the ADVANCED SETTINGS page. For a detailed parameter list, please refer to the corresponding firmware release configuration template.

When Grandstream Device boots up or reboots, it will issue request for configuration file named “cfgxxxxxxxxxxxx”, where “xxxxxxxxxxxx” is the MAC address of the device, i.e., “cfg000b820102ab”. The configuration file name should be in lower cases.

7.3Firmware and Configuration File Prefix and Postfix

Starting from firmware version 1.0.7.11 for HandyTone-486 Rev 2.0, adding prefix and postfix for both firmware and configuration file is supported.

Firmware Prefix and Postfix allows device to download the firmware name with the matching Prefix and Postfix. This makes it the possible to store ALL of the firmware with different version in one single directory. Similarly, Config File Prefix and Postfix allows device to download the configuration file with the matching Prefix and Postfix. Thus multiple configuration files for the same device can be stored in one directory.

In addition, when the field “Check New Firmware only when F/W pre/suffix changes” is set to “Yes”, the device will only issue firmware upgrade request if there are changes in the firmware Prefix or Postfix.

7.4Managing Firmware and Configuration File Download

When “Automatic Upgrade” is set to “Yes”, Service Provider can use P193 (Auto Check Interval, in minutes, default and minimum is 60 minutes) to have the devices periodically check with either Firmware Server or Config Server, whenever they are defined. This allows the device periodically check if there are any new changes need to be taken on a scheduled time. By defining different intervals in P193 for different devices, Server Provider can spread the Firmware or Configuration File download in minutes to reduce the Firmware or Provisioning Server load at any given time.

33

Image 33
Contents For Firmware Version HandyTone-286 RevTable of Contents Glossary of Terms Grandstream Networks, IncWelcome Installation What is Included in the Package Safety CompliancesWarranty Product Overview Key FeaturesModel HandyTone-286 Hardware SpecificationBasic Operations Get Familiar with Key Pad and Voice PromptMenu Voice Prompt User’s Options Make Phone Calls Calling Phone or Extension NumbersDirect IP Calls Call Waiting Call HoldCall Transfer Voice Prompt with option 47, thenCall Features 6 3-way ConferencingAttended Transfer Fax LED Light Pattern Indication Configuration Guide Configuring HandyTone-286 IP through Voice PromptConfiguring HandyTone-286 with Web Browser Registered Yes PPPoE Link Up disabled End User ConfigurationIP Address Product Model HT286 REV Software VersionNAT Statistical Status NAT Mapped PortTime Zone Daylight SavingsEnd User Password IP Address Time Zone Daylight Savings Advanced User ConfigurationSip.mycompany.com, or IP address SIP User IDAuthenticate ID Authenticate Password NameCan be identical to or different from SIP User Yes use Yes only if proxy supports 484 response UAC UAS Admin Password Yes configuration update via keypad is disabled if set toAuthenticate YesGrandstream Networks, Inc Grandstream Networks, Inc MWI Caller ID Scheme Special FeaturesOnhook Voltage Polarity ReversalSyslog Level Session Expiration Min-SE Caller Request Timer Grandstream Networks, Inc Rebooting the HandyTone-286 from Remote Saving the Configuration ChangesConfiguration through a Central Server Firmware Upgrade through TFTP/HTTP Software Upgrade with TftpConfiguration File Download Firmware and Configuration File Prefix and PostfixManaging Firmware and Configuration File Download Step Restore Factory Default SettingGlossary of Terms Did DNSDSP DtmfFXS Echo CancellationDhcp 323IVR IP-PBXMTU NTPRtcp PstnRTP SDPUDP TftpVAD Vlan