Procom EVS200 user manual Operation Selftest Bite, Battery operation

Page 21

VOR/ILS Analyzer EVS200

Chapter 3: Operation

Selftest (BITE)

 

 

The selftest checks:

￿

all operating voltages,

 

￿

host processor,

 

￿

memory,

 

￿

DSP processor.

In case of an error the determined functional unit will be indicated with a "FAIL". If the internal operating voltages totally fail or if they deviate extraordinary from the tolerances a selftest cannot be carried out.

Error:

In case of an error the unit generally should be switched off and after a few seconds it schould be switched on again. If the error message is displayed again it is recommended to send the unit to the service, corresponding to Chapter 5 (Service).

Battery operation

The battery operation of the VOR/ILS Analyzer EVS200 is an optional component. It is always pos- sible to retrofit the unit with this mode.

The unit automatically goes into battery operation when the external power supply (DC/AC) is switched or cut off. The battery operation is indicated on the display by the battery symbol () in each mode.

The operation time is >100 minutes (max. brightness) or >150 minutes (at average brightness) with a completely charged battery.

The charging state can be seen from the battery symbol on the display:

100% battery power

approx. 75 to 25% battery power

flashing symbol, approx. only 5 minutes operation is ensured. Battery must be charged.

The battery will be charged on AC operation (as well during operation as on "STANDBY") and should take at least 12 hours (charging time).

After 4 to 5 years or when defect the battery must be

changed according to Chapter 5 "Service".

0796.1800.02

E-8

12

Image 21
Contents VOR/ILS Analyzer EVS200 VOR/ILS Analyzer EVS200 Issue Version E8 EVS200 0201796.1800.02 Rohde & Schwarz GmbH & Co. KGPage Safety Instructions Safety Instructions Operator Information ContentsPreparation for Operation OperationRS-232-Interface operation InterfacesTechnical Specification ServiceService Warranty Technical data General data AccessoriesOperator Information Important operator informationUnpack the VOR/ILS Analyzer EVS200 UnpackingApplication of the unit Characteristics of the unit Unit layout frontview Unit layout rearview Placing the unit Safety RulesPreparation for Operation Mains connectionAssembling the FO Cable Jack Cable specification FO cable jackAntenna connection AF OUTRS-232-Interface Preparation for Operation External AF input SetupDSP output ILS-Mode VOR-Mode DisplaySwitch On/switch Off the unit at VDC supply Switch On/switch Off the unit at mains supplySwitch on procedure OperationOperation Selftest Bite Battery operationDispl 2/2 Parameter Description Setting value SETUP-ModeOperation Operating instructions of SETUP-Mode Operating instructions of ILS-Mode ILS-ModeOperation Operating instructions of Y /t setup menu Operation Operating instructions of Store DDM menu Operation Displ 1/2 Signal parameters on ILS displayDispl 2/2 StoreOperating instructions of VOR-Mode VOR-ModeSignal parameters on VOR display Operating instructions of BEACON-Mode BEACON-ModeDisplay indication Description Measuring value Signal parameters on Beacon displayOperating instructions of Δ Level-Mode Level-ModeOperation Storing and recalling reference levels VOR/ILS Analyzer EVS200 Signal parameters on Δ Level Display Operating instructions of Spectrum-Mode Spectrum-ModeRS-232-Interface operation Control commandsCOM-Parameter HandshakeCommand RF frequency in kHz Function Unit related control commandsCommand LO Function Command EC0 FunctionCommand test Function Command EC1 FunctionCommand LA Function EC1Command BI Function Command RES FunctionRES Reset Rescr Ready CR/LFCommand ML Function Command VER FunctionCommand MV Function ML Mode-Delta Level Level mode settingCommand MI Function Mode related control commands ILS-ModeCommand MB Function Command DD0 FunctionCommand SD0 Function Command DD1 FunctionCommand SD1 Function DD1Command AM3 Function Command AM2 FunctionCommand PH Function Phase 90/150 Hz Query of Phase angle 90/150 HzCommand BW1 Function Command BW0 FunctionBW0 bandwidth information KHz bandwidth setting BW1 bandwidth information KHz bandwidth settingOFF Command FA1 FunctionModulation depth Command FA2 FunctionAM90 CR , AM 150 CR Command FA3 FunctionExample CR DDM CR RF levelCommand D1 Function Command FA0 FunctionCommand D2 Function D1 display information Switch over to display1Command AM8 Function Command AF8 FunctionCommand AM9 Function AF8 AF-frequency ID AF-frequency ID queryCommand AM0 Function Command be FuncionCommand AM1 Function VOR-ModeCommand FM1 Function Command FM0 FunctionFM0 FM1D2 Display-information Switching over to Display2 FA2 Fast measuring on Activating the Fast measurement mode FM-deviationFM-Index Example Command from the controller Input e.g. a FA3 Fast measuring on Activating the Fast measurement modeCommand LR Function Command SR FunctionCommand LD Function Level-ModeCommand AM5 Function Command AM4 FunctionCommand AM6 Function Beacon-ModeCommand AM7 Kommando Funktion Command AF4 FunctionCommand AF5 Function Command AF7 Funktion Command AF6 FunctionAF6 AF7Interfaces RS-232-Interface Labeling Description Interfaces External AF input Labeling DescriptionExternal VDC connection Mains connection Labeling DescriptionService Technical data ILS signal analysisReceiver section VOR signal analysis Dimensions and Weight Temperature rangeEMC Order notificationAccessories Description Ident No