VOR/ILS Analyzer EVS200
|
| Chapter 3: Operation | |
Command AM2 |
|
|
|
|
| ||
command | function |
| |
AM2 <AM modulation depth (90 Hz)> | query of AM modulation depth (90 Hz) |
| |
|
|
|
|
The command AM2 reads the actual AM modulation depth (90 Hz) in the ILS mode.
Example: |
|
|
|
| command from the controller | response of the VOR/ILS Analyzer EVS200 | |
query: | AM2 <CR> | e.g. | 50% <CR/LF> |
| am2 <CR> | e.g. | 50% <CR/LF> |
Command AM3
command | function |
| |
AM3 | <AM modulation depth (150 Hz)> | query of AM modulation depth (150 Hz) | |
| |||
The command AM3 reads the actual AM modulation depth (150 Hz) in the ILS mode. | |||
Example: |
|
| |
| command from the controller | response of the VOR/ILS Analyzer EVS200 | |
Query: | AM3 <CR> | e.g. | 29.9% <CR/LF> |
| am3 <CR> | e.g. | 29.9% <CR/LF> |
Command PH
command | function |
| |
PH | <Phase 90/150 Hz> | query of Phase angle 90/150 Hz | |
| |||
The command PH reads the actual PHI value between 90 Hz and 150 Hz in the ILS mode. | |||
Example: |
|
| |
| command from the controller | response of the VOR/ILS Analyzer EVS200 | |
query: | PH <CR> | e.g. | 119.9DEG <CR/LF> |
| ph <CR> | e.g. | 119.9DEG <CR/LF> |
0796.1800.02 | 37 |