Procom EVS200 Command AM7 Kommando Funktion, Command AF4 Function, Command AF5 Function

Page 60

VOR/ILS Analyzer EVS200

 

 

 

 

Chapter 3: Operation

Command AM7

 

 

 

 

 

 

 

 

 

Kommando

Funktion

 

 

 

AM6

<AM-modulation depth ID>

query of AM-modulation depth ID

 

 

 

The command AM7 reads the actual AM-modulation depth (ID) in the BEACON mode.

Example:

 

 

 

 

 

command from the controller

response of the VOR/ILS Analyzer EVS200

query:

AM7 <CR>

e.g.

10.2% <CR/LF>

 

am7 <CR>

e.g.

10.2% <CR/LF>

Command AF4

command

function

 

AF4

<AF-frequency range F1>

query of AF-frequency 3000 Hz

 

The command AF4 reads the actual AF frequency (F1) in the BEACON mode.

Example:

 

 

 

command from the controller

response of the VOR/ILS Analyzer EVS200

query:

AF4 <CR>

e.g.

3000.0Hz <CR/LF>

 

af4 <CR>

e.g.

3000.0Hz <CR/LF>

Command AF5

command

function

 

AF5

<AF-frequency range F2>

query of AF-frequency 1300 Hz

 

The command AF5 reads the actual AF frequency (F2) in the BEACON mode.

Example:

 

 

 

command from the controller

response of the VOR/ILS Analyzer EVS200

query:

AF5 <CR>

e.g.

1300.0Hz <CR/LF>

 

af5 <CR>

e.g.

1300.0Hz <CR/LF>

0796.1800.02

E-8

51

Image 60
Contents VOR/ILS Analyzer EVS200 VOR/ILS Analyzer EVS200 Issue Version E8 0201 EVS200796.1800.02 Rohde & Schwarz GmbH & Co. KGPage Safety Instructions Safety Instructions Contents Operator InformationPreparation for Operation OperationInterfaces RS-232-Interface operationService Technical SpecificationService Warranty Technical data General data AccessoriesImportant operator information Operator InformationUnpacking Unpack the VOR/ILS Analyzer EVS200Application of the unit Characteristics of the unit Unit layout frontview Unit layout rearview Safety Rules Placing the unitPreparation for Operation Mains connectionCable specification FO cable jack Assembling the FO Cable JackAntenna connection AF OUTRS-232-Interface Setup Preparation for Operation External AF inputDSP output ILS-Mode VOR-Mode DisplaySwitch On/switch Off the unit at mains supply Switch On/switch Off the unit at VDC supplySwitch on procedure OperationBattery operation Operation Selftest BiteDispl 2/2 SETUP-Mode Parameter Description Setting valueOperation Operating instructions of SETUP-Mode ILS-Mode Operating instructions of ILS-ModeOperation Operating instructions of Y /t setup menu Operation Operating instructions of Store DDM menu Operation Signal parameters on ILS display Displ 1/2Displ 2/2 StoreVOR-Mode Operating instructions of VOR-ModeSignal parameters on VOR display BEACON-Mode Operating instructions of BEACON-ModeSignal parameters on Beacon display Display indication Description Measuring valueLevel-Mode Operating instructions of Δ Level-ModeOperation Storing and recalling reference levels VOR/ILS Analyzer EVS200 Signal parameters on Δ Level Display Spectrum-Mode Operating instructions of Spectrum-ModeControl commands RS-232-Interface operationCOM-Parameter HandshakeUnit related control commands Command RF frequency in kHz FunctionCommand LO Function Command EC0 FunctionCommand EC1 Function Command test FunctionCommand LA Function EC1Command RES Function Command BI FunctionRES Reset Rescr Ready CR/LFCommand VER Function Command ML FunctionCommand MV Function ML Mode-Delta Level Level mode settingMode related control commands ILS-Mode Command MI FunctionCommand MB Function Command DD0 FunctionCommand DD1 Function Command SD0 FunctionCommand SD1 Function DD1Command AM2 Function Command AM3 FunctionCommand PH Function Phase 90/150 Hz Query of Phase angle 90/150 HzCommand BW0 Function Command BW1 FunctionBW0 bandwidth information KHz bandwidth setting BW1 bandwidth information KHz bandwidth settingCommand FA1 Function OFFCommand FA2 Function Modulation depthCommand FA3 Function AM90 CR , AM 150 CRExample CR DDM CR RF levelCommand FA0 Function Command D1 FunctionCommand D2 Function D1 display information Switch over to display1Command AF8 Function Command AM8 FunctionCommand AM9 Function AF8 AF-frequency ID AF-frequency ID queryCommand be Funcion Command AM0 FunctionCommand AM1 Function VOR-ModeCommand FM0 Function Command FM1 FunctionFM0 FM1D2 Display-information Switching over to Display2 FA2 Fast measuring on Activating the Fast measurement mode FM-deviationFM-Index FA3 Fast measuring on Activating the Fast measurement mode Example Command from the controller Input e.g. aCommand SR Function Command LR FunctionCommand LD Function Level-ModeCommand AM4 Function Command AM5 FunctionCommand AM6 Function Beacon-ModeCommand AM7 Kommando Funktion Command AF4 FunctionCommand AF5 Function Command AF6 Function Command AF7 FunktionAF6 AF7Interfaces Interfaces External AF input Labeling Description RS-232-Interface Labeling DescriptionExternal VDC connection Mains connection Labeling DescriptionService Technical data ILS signal analysisReceiver section VOR signal analysis Temperature range Dimensions and WeightEMC Order notificationAccessories Description Ident No