Kramer Electronics VP-720xl PIP Source Appearance Availability2, Activating the PIP Feature

Page 22

Presentation Switcher / Scaler Buttons

When selecting one PIP source, your Presentation Switcher / Scaler automatically recognizes and displays the selected graphic PIP source on all the video displays1 and the selected video source on all the graphic1 displays, compliant to Table 4.

Table 4: PIP Source Appearance Availability2

The selected PIP

 

AV1, AV2, YC1, YC2, or component

Component (graphics), DVI, VGA1, or

source:

 

(video)

VGA2

Appears on:

 

Component (graphics), DVI, VGA1, and

AV1, AV2, YC1, YC2, and component

 

 

VGA2

(video)

Does not appear on

:

AV1, AV2, YC1, YC2, and component

Component (graphics), DVI, VGA1, and

 

 

(video)

VGA2

 

 

 

 

7.2.2Activating the PIP Feature

After setting the PIP source you can activate the PIP by:

￿￿Pressing the PIP button

￿￿Pressing the PIP key on the infra-red remote control transmitter (see section 7￿ .4, Figure 16)

￿￿Switching on the PIP functionality via the OSD Menu (see section 8￿ .5.4, Figure 35)

7.2.3The PIP Source (Orange) Frame

Whether the PIP source is enclosed by an orange frame or not, determines the functionality of the operation buttons (on the machine and remote control transmitter). For example, when the Source Prompt is ON, and the PIP Frame is ON, you can instantly position the PIP using the preset position control keys3.

When pressing the PIP button while the PIP Frame is ON (see section 8￿ .5.4):

￿￿The PIP appears enclosed in an orange frame

￿￿After a few seconds4 the orange frame disappears

￿￿When pressing the PIP button once again, the orange frame reappears

When pressing the PIP button while the PIP Frame is OFF (see section 8￿ .5.4), the PIP source toggles between PIP and no PIP, with no orange frame.

1 Even if the input signal is not connected. In this case the PIP appears over a blank screen

2 Since the component input is compatible with both video and graphic sources, the type of component source (video or graphic) determines where it is positioned in the table

3 On the infra-red remote control transmitter to instantly move the position of the PIP window to up to nine preset fixed locations (see Figure 16). For example, to move to the lower right corner of the image, press the button

4 By default, 20 seconds. But you can reset the timeout (from 3 to 60 seconds), see section 8￿ .5.6

18

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Image 22
Contents Models Contents Figures Tables OSD Output StatusIntroduction Getting StartedThis Quick start chart summarizes the basic steps Quick StartOverview Overview Your Presentation Switcher / Scaler Illustrate the VP-719xlPresentation Switcher / ScalerVP-719xl Presentation Switcher / Scaler Front Panel1 VP-720xl Presentation Switcher / Scaler Front Panel1 VP-723xl Presentation Switcher / Scaler Front Panel1 VP-724xl Presentation Switcher / Scaler Front Panel Front Panel Presentation Switcher / Scaler Features Feature FunctionRear Panel Presentation Switcher / Scaler Features RCARecommended Ambient Temperature and Humidity Range Installing on a RackBefore Installing on a Rack Instructions for Rack-MountingConnecting your Presentation Switcher / Scaler Connecting the VP-724xl Rear Panel Connecting a PC Connecting the PCPresentation Switcher / Scaler Buttons Switching an InputPIP Button Feature Selecting the PIP SourcePIP Source Appearance Availability2 Activating the PIP FeaturePIP Source Orange Frame Toggling between the PIP and the Screen Source Swap PIP CharacteristicsResizing the PIP PIP Size Split Screen Moving the Position of the PIPInfra-Red Remote Control Transmitter Locking and Unlocking the Front PanelInfra-Red Remote Control Transmitter Infra-Red Remote Control Transmitter Functions Eys FunctionColor Configuring the VP-724xl via the OSD Menu ScreensBrightness Gamma Source Geometry Utility InformationSetting Function Range Default Controlling the Brightness and ContrastButton Function Range Default Controlling the Gamma and ColorSelecting the Source Controlling the Scale GeometrySetting the Scale Features Geometry Scale Aspect Ratio Screen Graphic SourceButton Unction Adjusting the Zoom Ratio and PositionGeometry Scale Functions Button FunctionOSD Enlarge Status Geometry Zoom Ratio ScreenPreset Position Control Keys Navigation Control KeysConfiguring via the Utility Screens Choosing the Graphic Utility SettingsButton Unction Ange Default Graphic Setting Utility Screen FeaturesChoosing the Video Utility Settings NTSC, NTSC4.43, PAL, PAL-N, PAL-M, SecamChoosing the Audio Utility Settings Choosing the PIP Utility SettingsChoosing the Seamless Switch Utility Settings PIP Setting Utility Screen FeaturesSeamless Switch Utility Screen Features Choosing the OSD Utility Settings Set the Source Prompt Blank ColorResolution Choosing the Output Utility SettingsOutput Setting Utility Screen Features For advanced users onlyUser Mode Setting Definitions User Mode SettingOclk Choosing Advanced Utility Settings Choosing Factory ResetAdvanced Utility Screen Features User Define Measure Features Setting an Input to a Non-standard Resolution ExampleVerifying Configuration Details via the Information Screen Non-standard Resolution in the Information ScreenTechnical Specifications AV1 AV2 10 VP-724xl Communication ProtocolControl Function Param Comment Type For Set Description YC1 YC2 VGA1PIP NTSC/NTSC 4.43/PAL Set ~32 Audio Setting Get VolumeControl Function Param Comment Type Set PAL Get Video V-Position for ~39Get Size Set ~36 Get Size Set ~255Get Set ~36 Video Standard Off Get Set OSD Setting Blank Color Blue BlackSecam 0 CR Load Gamma/Color Presentation CinemaVideo Stand Return Z 8 1080i CR Only the first purchase customer may enforce this warranty 2900-000034 REV