Kramer Electronics VP-723xl, VP-724xl, VP-720xl, VP-719xl user manual User Define Measure Features

Page 44

Configuring the VP-724xl via the OSD MENU Screens

Table 19 describes the User Define Measure features.

Table 19: User Define Measure Features

 

User Mode Setting Definitions

H Total

Horizontal Total

H Start

Horizontal active start point

H Active

Horizontal active region

V Start

Vertical active start point

V Active

Vertical active region

Ch. Pump

Charge pump current

Color

Color format

H Freq

Horizontal Frequency

V Freq

Vertical Frequency

Measure Mode

Select between Default and User Define

8.5.9.1 Setting an Input to a Non-standard Resolution (Example)

When connecting a source with a non-standard resolution, you have to set your scaler to this resolution so it will correctly identify this source. The Advanced mode lets you set up to three non-standard resolutions. To set an input to a non-standard resolution, for example to 1100x800, do the following:

1.Connect the source (with the non-standard resolution, in this example – 1100x800) to the appropriate input connector on your scaler and press the appropriate INPUT SELECTOR button.

2.Connect the VIDEO OUT 1/2 HD15F connector to a video acceptor.

3.Turn the machines ON.

4.Press menu, go to Utility>Advanced> User Define Measure, and press

ENTER.

5.Scroll to Measure Mode, press ENTER and select User Define.

6.Set H Active to 1100 and V Active to 800, and set the remaining parameters according to the input data.

7.Scroll to the Save Mode and save the new resolution.

8.Open the Information screen and check that the new resolution appears in the Main Source line1 (see Figure 43).

1 Note that for the Scaler to correctly read the input, its OCLK value should be different from that of any other defined input of the scaler

40

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Image 44
Contents Models Contents Figures Tables OSD Output StatusIntroduction Getting StartedThis Quick start chart summarizes the basic steps Quick StartOverview Overview Your Presentation Switcher / Scaler Illustrate the VP-719xlPresentation Switcher / ScalerVP-719xl Presentation Switcher / Scaler Front Panel1 VP-720xl Presentation Switcher / Scaler Front Panel1 VP-723xl Presentation Switcher / Scaler Front Panel1 VP-724xl Presentation Switcher / Scaler Front Panel Front Panel Presentation Switcher / Scaler Features Feature FunctionRear Panel Presentation Switcher / Scaler Features RCAInstalling on a Rack Before Installing on a RackRecommended Ambient Temperature and Humidity Range Instructions for Rack-MountingConnecting your Presentation Switcher / Scaler Connecting the VP-724xl Rear Panel Connecting a PC Connecting the PCPresentation Switcher / Scaler Buttons Switching an InputPIP Button Feature Selecting the PIP SourcePIP Source Orange Frame Activating the PIP FeaturePIP Source Appearance Availability2 Resizing the PIP PIP CharacteristicsToggling between the PIP and the Screen Source Swap PIP Size Split Screen Moving the Position of the PIPInfra-Red Remote Control Transmitter Locking and Unlocking the Front PanelInfra-Red Remote Control Transmitter Infra-Red Remote Control Transmitter Functions Eys FunctionConfiguring the VP-724xl via the OSD Menu Screens Brightness GammaColor Source Geometry Utility InformationSetting Function Range Default Controlling the Brightness and ContrastButton Function Range Default Controlling the Gamma and ColorSelecting the Source Controlling the Scale GeometrySetting the Scale Features Geometry Scale Aspect Ratio Screen Graphic SourceAdjusting the Zoom Ratio and Position Geometry Scale FunctionsButton Unction Button FunctionOSD Enlarge Status Geometry Zoom Ratio ScreenPreset Position Control Keys Navigation Control KeysConfiguring via the Utility Screens Choosing the Graphic Utility SettingsGraphic Setting Utility Screen Features Choosing the Video Utility SettingsButton Unction Ange Default NTSC, NTSC4.43, PAL, PAL-N, PAL-M, SecamChoosing the Audio Utility Settings Choosing the PIP Utility SettingsSeamless Switch Utility Screen Features PIP Setting Utility Screen FeaturesChoosing the Seamless Switch Utility Settings Choosing the OSD Utility Settings Set the Source Prompt Blank ColorChoosing the Output Utility Settings Output Setting Utility Screen FeaturesResolution For advanced users onlyOclk User Mode SettingUser Mode Setting Definitions Advanced Utility Screen Features Choosing Factory ResetChoosing Advanced Utility Settings User Define Measure Features Setting an Input to a Non-standard Resolution ExampleVerifying Configuration Details via the Information Screen Non-standard Resolution in the Information ScreenTechnical Specifications 10 VP-724xl Communication Protocol Control Function Param Comment Type For Set DescriptionAV1 AV2 YC1 YC2 VGA1PIP Set ~32 Audio Setting Get Volume Control Function Param Comment TypeNTSC/NTSC 4.43/PAL Set PAL Get Video V-Position for ~39Get Set ~36 Get Size Set ~255Get Size Set ~36 Secam Off Get Set OSD Setting Blank Color Blue BlackVideo Standard Video Stand Return Z 8 1080i CR Load Gamma/Color Presentation Cinema0 CR Only the first purchase customer may enforce this warranty 2900-000034 REV