Cisco Systems A03D1TBSATA, UCS C220 M3 manual Technical Specifications

Page 61

TECHNICAL SPECIFICATIONS

Table 32 UCS C220 M3 SFF 450 W Power Supply Specifications

DescriptionSpecification

Power supply efficiency

CSCI Platinum

 

 

 

 

 

 

NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet.

The general power specifications for the C220 M3 SFF server 650 W power supply are listed in Table 32.

Table 33 UCS C220 M3 LFF 650 W Power Supply Specifications

Description

Specification

 

 

 

AC input voltage

90 to 264 VAC self-ranging,

 

 

100 to 120 VAC nominal

 

 

200 to 240 VAC nominal

AC input frequency

Range: 47 to 63 Hz (single phase, 50 to 60 Hz nominal)

Maximum AC input current

7.6 A peak at 100 VAC

 

 

3.65 A peak at 208 VAC

Maximum AC inrush current

11 A

Maximum output power for the

650 W

power supply

 

Power supply output voltage

Main power: 12 VDC

 

 

Standby power: 12 VDC

Power supply efficiency

CSCI Platinum

 

 

 

 

 

 

NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet.

For configuration-specific power specifications, use the Cisco UCS Power Calculator at this URL:

https://express.salire.com/Go/Cisco/Cisco-UCS-Power-Calculator.aspx

Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)

61

Image 61
Contents SAN JOSE, CA REV A.16 October 9 Contents Overview Shows the Cisco UCS C220 M3 High-Density SFF Rack Server Chassis Front ViewChassis Rear View Shows the external features of the rear panelCPU Capabilities and Features Capability/Feature DescriptionNIC UCSC-RAID-MZ-220 Capability/Feature DescriptionPlug-in PCIe Cards 6 Gbs Drives can be mixedCapability/Feature Description Configuring the Server Verify the product ID PID of the server as shown in Table Verify Server SKUCards, with 1 rail kit Dimm Clock Select CPUsNumber GHz Support MHz1 Select any one CPU listed in Table Approved Configurations CPU configurationsSelect two identical CPUs from any one of the rows of on CaveatsC220 M3 SFF Memory Organization Select MemoryDimm Options Select DIMMs and Memory MirroringMemory Mirroring Option CPU configuration with memory mirroring CPU configuration with memory mirroring Caveats Select RAID Options Select RAID ConfigurationUCSC-RAID-ROM5 SupportUCS-RAID-9266CV UCS-RAID-9266NBSuper Capacitor Option UCS-RAID-CV-SC=R2XX-RAID1 R2XX-RAID0R2XX-RAID5 R2XX-RAID6Approved Configurations CPU Configurations HDDs Select DrivesSSDs You can mix Sata and SAS drives Network Interface Cards NICs Select PCIe Option CardsHost Bus Adapters HBAs One RAID controller plug-in card Approved Configurations No RAID controller plug-in cardChoose Optional Twinax Cables Order Optional Network Card AccessoriesAvailable Twinax Cables Product ID PID PID Description Available SFP Modules Product ID PID PID Description Choose Optional SFP ModulesSFP-10G-SR DS-SFP-FC8G-SWNetwork Card Connections Power Supply PIDs Order Power SupplyPower supply Product ID PID PID DescriptionR2XX-DMYMPWRCORD Available Power Cords Product ID PID PID Description ImagesCAB-N5K6A-NA CAB-C13-CBNCAB-9K10A-EU CAB-9K10A-AUAvailable Power Cords Product ID PID PID Description Cable Management Arm Order Optional Reversible Cable Management ARMCable Management Arm for C220 rack servers Trusted Platform Module Product ID PID PID Description Order a Trusted Platform ModuleUCSX-TPM1-001 Trusted Platform Module Secure Digital SD Card Order Cisco Flexible Flash SD Card Module OptionalOrder Optional USB 2.0 Drive See on page 47 for the location of the USB connectorUSB 2.0 Drive Red Hat Enterprise Linux Select Operating SystemRhel Add-Ons Windows ServerOperating Systems PID Description Product ID PID Select the optional operating system media listed in Table Select Operating System Media KITOS Media Product ID PID PID Description RHEL-6Value Added Software Select Optional VALUE-ADDED SoftwareUnified Computing Support Service Unified Computing Warranty, No ContractUCS Computing Support Service Product ID PID On Site? DescriptionUnified Computing Drive Retention Service Unified Computing Warranty Plus ServiceService With Drive Retention Support Service With Drive RetentionUCS Warranty Plus Mission Critical Support ServiceConfiguring the Server Racks and Rack Options Product ID PID PID Description RP208-30-2P-U-2 Zero RU PDU PDU OptionsFor more information about the PDU, see PDUs, Supplemental Material Physical Layout CPUs and DIMMsCPU1 Memory Population Rules E2, F2 MHz System C1, D1 C2, D2 A2, B2G2, H2 4x4 GB 1600 2x8 GB4x16 GB 2x16 GB 1600 4x8 GB 2x32 GB 1x32 GB E2, F2 MHz System1 C1, D1 C2, D24x16 GB 1600 2x32 GB 4x32 GB 1600Supported Dimm populations are listed in Table Supported Dimm Configurations Total DIMMsCPU 1 DIMMs CPU 2 DIMMs Capacity for For CPU Low-Voltage Dimm Considerations RAID SummaryRacks Cisco R42610 Rack Zero Rack Unit PDU PID = RP208-30-2P-U-2 PDUsKVM cable for B-Series Blade Server console port KVM Cable Product ID PID PID DescriptionKVM Cable Motherboard USB and SD Ports, and RAID Card Backup Location Power Specifications Dimensions and WeightUCS C220 M3 Dimensions and Weight Parameter Value Technical Specifications UCS C220 M3 Environmental Specifications Parameter Minimum Environmental SpecificationsCISPR24 Compliance RequirementsEN300386 KN24Technical Specifications