Cisco Systems 6200 appendix Transmission Rates and Modem Training

Page 28

1 Hardware Description

78-5296-02 10/02/98

In the upstream direction, the SLC receives ADSL signals from a POTS splitter and demodulates the DMT-modulated signal. Then the SLC channel contends with the other SLC channels for the upstream data bus. Two priority levels are available. For the first Cisco 6200 release, only UBR service is available. The SLC will ensure fair access among all cells of the same priority.

The SLC separates the upstream and downstream data channels:

The upstream data channel occupies a band between 25.875 kHz and 138 kHz.

The downstream data channel takes the band between 138 kHz and 1.104 MHz.

At the subscriber site, the DSL customer premises equipment (CPE)—the Cisco 676, for example— demodulates the downstream signal and sends the data to the subscriber’s PC.

Transmission Rates and Modem Training

Two modes are available for setting transmission rates:

Rate-adaptive mode: You can set the subscriber ports to adapt (train) automatically to the highest line speed attainable for the configured signal-to-noise ratio (SNR) margin for each direction.

Explicit rate mode: You can set SNR margins and transmission speeds explicitly. Upstream and downstream speeds can be set separately.

You can mix rate-adaptive and explicit modes on the same circuit, using one mode for upstream traffic and the other for downstream traffic.

Rates available for downstream traffic range from 32 kbps to 8.032 Mbps, in increments of 32 kb (32 kbps, 64 kbps, 96 kbps, 128 kbps, and so on). Rates available for upstream traffic start at 32 kbps and increase in 32-kb increments to a maximum upstream rate of 864 kbps.

The modems on the SLC 8DMT train simultaneously in the upstream and downstream directions. Each modem first tries to train at the configured rate at a specified SNR margin. If the first attempt fails in either direction but a CPE is detected, the modem tries to train at the highest rate possible (up to the configured rate). The modem keeps trying to train until it is successful.

Statistics

The SLC 8DMT gathers signal quality statistics for network management purposes and sends this information to the management system via SNMP. The SLC reports each of the following statistics to the management system for both upstream and downstream traffic:

Near and far end uncorrected blocks

Near and far end corrected blocks

Near and far end loss of signal (LOS) counter

Near end loss of frame (LOF) counter

Remote failure indication (RFI, or far end LOF)

Near and far end errored seconds

Near and far end attenuation

Near and far end SNR margin

Upstream and downstream actual rates

Number of nonidle cells transmitted downstream

Number of nonidle upstream cells received with valid header checksum

1-28Cisco 6200 User Guide

Image 28
Contents Hardware Description Cisco DSL Product FamilyCisco 6200 Chassis Module CompartmentBackplane Cisco 6200 Chassis, Front ViewEthernet Management Bus Primary a and Secondary B H-BusesCisco 6200 Chassis, Rear View Alarm Relay Connection Connections to Pots Splitters or Telephone LinesPower Entry Modules PEMs Power TerminalsUnused Connectors Fan TrayCooling Vents Dslam SpecificationsCisco 6200 Dslam Specifications Specification DescriptionStandards and Certifications Category DescriptionWhat is the NTC OC-3? Network Trunk Cards NTCsNTC OC-3 Physical Description OC-3c Trunk PortReset Switch LED IndicatorsDescribes the LEDs on the faceplate of the OC-3 NTC NTC OC-3 FaceplatesLEDs on the NTC OC-3 Color Condition IndicatedWhat is the NTC STM-1? NTC OC-3 SpecificationsLists the physical and electrical specifications of the NTC NTC OC-3 SpecificationsNTC STM-1 Application NTC STM-1 Physical Description Trunk PortDescribes the LEDs on the faceplate of the NTC STM-1 NTC STM-1 FaceplatesNTC STM-1 Specifications LEDs on the NTC STM-1Management Processor Card MPC Functional DescriptionCisco 6200 is controlled and managed by the MPC NTC STM-1 SpecificationsPhysical Description ACO SwitchMPC Faceplate Console Port Pcmcia Slots and Ejection ButtonsEthernet Port All LEDs on the MPC are described in TableLists the physical and electrical specifications of the MPC MPC SpecificationsMPC Specifications What is the SLC 8CAP? Subscriber Line Card SLCHow the SLC Handles Traffic Transmission Rates and Modem TrainingStatistics 10 SLC 8CAP OperationDescribes the LEDs on the faceplate of the SLC SLC 8CAP Physical DescriptionSLC 8CAP Faceplate SLC 8CAP LEDs SLC 8CAP Specifications SLC 8CAP SpecificationsWhat is the SLC 8DMT? How the SLC 8DMT Handles TrafficTwo modes are available for setting transmission rates SLC 8DMT Physical Description 11 describes the LEDs on the faceplate of the SLC SLC 8DMT FaceplateSLC 8DMT LEDs SLC 8DMT Specifications SLC 8DMT Specifications