Dell manual T610 Supported TBUs

Page 43

Dell™ PowerEdge™ T610 Technical Guidebook

F. Optical Drives

SATA optical drives are optional in all PowerEdge T610 systems and connect to the planar via the SATA interface to ICH9. IDE (PATA) optical drives are not supported.

The following internal optical drives are available on the PowerEdge T610: DVD-ROM and DVD+/-RW.

If the optical drive is not ordered with the system, a blank is installed in its place. In the absence of tape drive, an optional second SATA optical drive is installed in the bay adjacent to the first optical drive.

G. Tape Drives

A tape backup unit (TBU) is optional in all PowerEdge T610 systems and connects to the planar SATA, SCSI controller card, or SAS controller card. An IDE tape drive is not supported.

The PowerEdge T610 supports a maximum of one half-height or one full-height TBU. A full-height TBU would take up both drive bays and would prevent an optical drive from being installed.

The following tape drives are available for usage on the PowerEdge T610: internal SATA, SCSI, and SAS drives; external SCSI and SAS drives. Internal SCSI tape drives connect through the LSI 2032 PCI Express SCSI adapter card. SAS TBUs connect through the SAS5iR card.

If the tape drive is not ordered with the system, a blank is installed in its place.

T610 Supported TBUs

 

 

 

Catfish Internal (RD1000 Half-Height SATA)

 

 

 

LTO2L (Legacy, Half-Height, SCSI)

Internal Tape

 

LTO3-060 & LTO3L-060 (Half-Height SCSI)

 

 

 

LTO4-120 (Half-Height, Low-Cost, SAS)

 

 

 

DAT72 Half–Height SCSI

 

 

Internal Tape

One 3.5" half-height tape drive bay (Catfish)

 

Drive Bays

One 5.25" half-height tape drive bay (LTO4, 3, 2 value)

 

 

 

 

Catfish External (RD1000 USB)

 

 

 

LTO-2L (Legacy, SCSI)

 

 

 

LTO-3-060 (SCSI)

External TBU

 

LTO-3 (Legacy, SCSI)

 

 

 

LTO-4-120 (Half-High SAS)

 

 

 

2U external TBU (Hammerhead – PV114T)

 

 

 

DAT72 Half–Height SCSI

 

 

 

Shadow 4U SAS, SCSI, iSCSI, and FC

 

 

External TBU/

Shadow 2U SAS, SCSI, iSCSI, and FC

 

Automation

ML6000 Family SAS, SCSI, and FC

 

 

 

 

2U external TBU (Seabass – PV124T) Legacy SCSI

 

 

 

Table: PowerEdge T610 supported TBUs

43

Image 43
Contents Poweredge T610 Table of Contents Chipset Block Diagram ProcessorsBios MemoryOperating Systems VideoAudio Rack InformationDocumentation PeripheralsPackaging Options Advanced Virtualization Strong IT FoundationPurposeful Design Energy-Optimized TechnologyBios Feature DetailsUSB RAIDMechanical Chassis Description Front Panel View and Features Dimensions and WeightBack Panel View and Features Indicator Indicator code Power Supply IndicatorsNIC Indicators Power Supply statusInternal Chassis Views Rails and Cable Management Fans Control Panel/LCD Figure PowerEdge T610 LCD PanelField Replaceable Units FRU BatterySecurity USB PeripheralsCOMPOnent Description Storage Location Power suppliesStorage cards Figure PowerEdge T610 Power Supply Power Supply SpecificationsMaximum vibration AC Power supply per power supplyTemperature Relative humidityFeature Energy Smart PSU High Output PSU Stressed Processor StandbyIdle Active Hard Disk DrivesFigure PowerEdge T610 Main Components Block DiagramDell PowerEdge T610 Technical Guidebook Features Nehalem-EP 2S Features ProcessorProcessors Overview / Description Core Model Speed Power Cache CoresBenefit Intel Turbo Boost TechnologyDIMMs Supported Memory Overview / DescriptionSpeed Udimm Rdimm Dimm type DImm Number of dimms 800 1066 1333Rdimm memory Memory Mode Module Size Supported ConfigurationsOptimizer 4GB Optimizer Memory ModeChipset Overview / Description Bios Overview / Description Proc number Qfd # Frequency Standard Tdp Lfm tdp State Supported Acpi StatesI2C Inter-Integrated Circuit Embedded NICs Overview / Description Poweredge T610 PCI Express Gen2 SlotsO Slots Overview / Description YK8 YY0 Constraints HDDs No RAID PowerEdge T610 RAID Configurations SAS/SATASSD/SAS SSDStorage Controllers Card T610 Support Storage Usage PowerEdge Slot PCIeLED Indicators Perc SAS/SATA LSI Scsi ICH Sata SAS HBA SAS/SATAT610 Supported TBUs Rack Information Overview / Description Resolution Refresh rate Hz Color Depth bitVideo Overview / Description Audio Overview / DescriptionRails PowerEdge T610 rack supports the followingPoweredge T610 rail supports the following Cable Management Arm CMAWindows Web Server X86 X64Windows Server 2008 x64 includes Hyper-V Windows ServerSolaris 10 05/09 Red Hat Enterprise LinuxNovell Suse Linux Enterprise Server 10 SP2 Novell Suse Linux Enterprise ServerServer Management Systems Management Overview / DescriptionFeature Description Snmp Wsman SMASH-CLP FeatureRemote Management & Remediation Security & AuthenticationIDRAC6 VFlash Express Enterprise Media ConductivityPV DAS IDRAC6 VFlash Express Enterprise Media Logging FeaturesExternal storage PV NASPackaging Provide packaging to support system Documentation Overview, Description, and ListEeprom APpendix aTPM Binding Eeprom How is data input to this memory? Planar, Poweredge T610 HW read only Not read only Plug in module only TPM Binding Eeprom