Index | Sensor Name | Event Triggers |
|
|
|
3 | BMC Watchdog | • Timer expired |
|
| • Hard reset |
|
| • Power down |
|
| • Power cycle |
4 | Processor | • IERR |
|
| • Thermal trip |
5 | BMC SEL | • SEL full (909 records) |
|
| • SEL almost full (909 x 75% = 681 records) |
6 | Processor Hot | State Asserted |
7 | System Event | PEF action |
8 | PCIE Error | Bus correctable error |
|
| Bus Uncorrectable error |
|
| Bus fatal |
9 | POST Error | System firmware error |
10 | CPU1_DIMM A1 | • Correctable error |
| CPU1_DIMM A2 | • Uncorrectable error |
| CPU1_DIMM A3 | • Correctable ECC error logging limit reached |
| CPU1_DIMM A4 |
|
11 | SYS FAN 1 ~ | • Lower critical going low |
| SYS FAN 8 | • Lower |
|
| |
12 | PSU 1 Status | • Presence detected |
| PSU 2 Status | • TEMPERATURE Failure detected |
|
| • IOUT Failure detected |
|
| • VOUT Failure detected |
|
| • FANS Failure detected |
|
| • INPUT Failure detected |
13 | PSU Redundancy | Redundancy lost |
14 | Mixed MB | • Mixed MB detected |
|
| • Key Slot error detected |
15