Dell C5220 manual Command NetFn

Page 54

Table 1-40. BMC Device and Messaging Commands

Command

NetFn

CMD

O/M

Supported

 

 

 

 

 

Master Write-Read I2C

App

52h

M

Yes

Get Channel Cipher Suites

App

54h

O

Yes

Suspend/Resume Payload

App

55h

O

Yes

Encryption

 

 

 

 

Set Channel Security Keys

App

56h

O

Yes

Get System Interface

App

57h

O

Yes

Capabilities

 

 

 

 

Table 1-41. BMC Watchdog Timer Commands

 

 

 

 

 

 

 

 

Command

NetFn

CMD

O/M

Supported

 

 

 

 

 

Reset Watchdog Timer

App

22h

M

Yes

Set Watchdog Timer

App

24h

M

Yes

Get Watchdog Timer

App

25h

M

Yes

 

 

 

 

 

Table 1-42. Chassis Commands

 

 

 

 

 

 

 

 

 

Command

NetFn

CMD

O/M

Supported

 

 

 

 

 

Get Chassis Capabilities

Chassis

00h

M

Yes

Get Chassis Status

Chassis

01h

M

Yes

Chassis Control

Chassis

02h

M

Yes

Chassis Reset

Chassis

03h

O

No

Chassis Identify

Chassis

04h

O

Yes

Set Chassis Capabilities

Chassis

05h

O

Yes

Set Power Restore Policy

Chassis

06h

O

Yes

Get System Reset Cause

Chassis

07h

O[1]

Yes

Set System Boot Options

Chassis

08h

O

Yes

Get System Boot Options

Chassis

09h

O

Yes

Set Front Panel Button Enable

Chassis

0Ah

O

Yes

Set Power Cycle Interval

Chassis

0Bh

O

Yes

54

Image 54
Contents Using the Baseboard Management Controller Typographic Conventions Contents Ipmi 1.5 / 2.0 Command Support List PEFPowerEdge C5220 BMC Key Features and FunctionsUsing the Web UI IntroductionDefault User Name And Password Field Logging in to the Web User InterfaceDefault User Name And Password FieldDefault Menu ItemBMC Summary BMC Information Description System FeaturesSystem Information DD Yyyy HhmmssComponent Information CPU InformationMemory Information Server Identify BlinkServer Identify Description Firmware Update Updating the BMC FirmwareClick Start Upgrade LEDs Power ButtonFront Panel User Interface BMC Heartbeat LEDLED SledIndex Sensor Name Event Triggers System Information List FRUComponent Information Server Health Server Health Options Button DescriptionSensor Readings Sensor Readings Button DescriptionSensor Readings With Thresholds Sensor Readings With Thresholds DescriptionTemperature Sensors 8-Sled Chassis Sensor Number Temperature MonitoringSystem supports the following temperature sensors Temperature Sensor Number11. Current Monitoring Sensor Number Current MonitoringFAN Control and Monitoring 12. Fan Thresholds Fan SensorEvent Log Event Log page shows the event logs from the managed system13. Event Log Description SOL Configuration14. Configuration Options Button Description SnmpSmtp PEFAlerts Lists all alert entries15. Alerts Description Modify Alert 16. Modify Alerts Items DescriptionMouse Mode 17. Mouse Mode DescriptionNetwork 18. Network DescriptionUse the following IP Vlan Settings 19. Vlan Settings Items DescriptionVlan ID 20. Serial Over LAN Settings Description SOLSOL Advanced Settings 21. Advanced SOL settings DescriptionSnmp 22. Snmp DescriptionSmtp page allows you to configure the Smtp mail server 23. Smtp DescriptionTo change the root password UsersAdd New User Add New User DescriptionAdd New User Description Modify User 24. Modify User Description25. PEF Description PEF#Modify PEF 26. Modify PEF DescriptionSSL Certificate 27. PEF DescriptionUploading Private Key 28. SSL Private Key Upload web DescriptionWeb Session 29. PEF DescriptionRemote Control Console RedirectionKeystroke Description 30. Console Redirection, Java Console Launch Description31. Remote Console Shortcut Key Combinations 32. Console Redirection Window Keyboard33. Console Redirection Window Mouse 34. Console Redirection Window Options Description 35. Console Redirection Window Options36. Console Redirection Window Device Menu Item Description Console Redirection Window Device Power Control38. Power Control and Status Menu Item Description Console Redirection Window Help38. Power Control and Status Menu Item Description Maintenance Languages40. BMC Device and Messaging Commands Ipmi 1.5 / 2.0 Command Support List39. Ipmi Device Global Commands NetFn Supported40. BMC Device and Messaging Commands Command NetFn 43. Event Commands NetFn Optional portion of Get System Reset Cause is not support42. Chassis Commands NetFn 44. SEL Commands NetFn45. SDR Repository Commands NetFn 47. Sensory Device Commands NetFn 48. LAN Commands NetFn49. SOL Command 50. PEF/PET Alerting Commands NetFn