Dell A03, R610 owner manual 169, Amperes AC Alternating current, Glossary

Page 169

Glossary

A — Ampere(s).

AC — Alternating current.

ACPI — Advanced Configuration and Power Interface. A standard interface for enabling the operating system to direct configuration and power management.

ambient temperature — The temperature of the area or room where the system is located.

ANSI — American National Standards Institute. The primary organization for developing technology standards in the U.S.

asset tag — An individual code assigned to a system, usually by an administrator, for security or tracking purposes.

backup — A copy of a program or data file. As a precaution, back up your system’s hard drive(s) on a regular basis.

blade — A module that contains a processor, memory, and a hard drive. The modules are mounted into a chassis that includes power supplies and fans.

bootable media — A diskette, or USB memory key, or optical media that is used to start your system in lieu of the hard drives.

BTU — British thermal unit.

bus — An information pathway between the components of a system. Your system contains an expansion bus that allows the processor to communicate with controllers for the peripheral devices connected to the system. Your system also contains an address bus and a data bus for communications between the processor and RAM.

C — Celsius.

cache — A fast storage area that keeps a copy of data or instructions for quick data retrieval.

cm — Centimeter(s).

COMn — The device names for the serial ports on your system. Serial ports can be either physical or virtual.

control panel — The part of the system that contains indicators and controls, such as the power button and power indicator.

controller — A chip or expansion card that controls the transfer of data between the processor and memory or between the processor and a peripheral device.

coprocessor — A chip that relieves the system’s processor of specific processing tasks. A math coprocessor, for example, handles numeric processing.

Glossary

169

Image 169
Contents Dell PowerEdge R610 Systems September Contents Entering the Uefi Boot Manager Processor Settings ScreenUefi Boot Settings Screen Using the System Password Using the Setup PasswordInstalling a Hard Drive Into a Entering the iDRAC Configuration UtilityExpansion Card Installation Guidelines Contents Installing the Internal SD Module Installing an Expansion Card Removing an Expansion CardInstalling an Internal SD Flash Card Installing a VFlash Media CardGeneral Memory Module Installation Installing the Integrated StorageReplacing the System Battery 127 Replacing the Plastic Fan Guide 108148 Troubleshooting Your System 141159 Disabling a Forgotten Password 163163 163167 You to select a boot device Accessing System Features During StartupYou to manage your system’s boot options F11Front-Panel Features and Indicators System error messages USB connectorsLCD panel displays an error Operating systems documentationOptional Or DVD+RW drive System identification LCD Panel FeaturesHome Screen Seconds to enter Bios Progress modeButtons Description Left Hold the system ID button for more than fiveView Menu Setup MenuOption Description Temperature Hard-Drive Indicator Patterns for RAIDAmber During this time Connects a VGA display to the system Back-Panel Features and IndicatorsPower supply 1 PS1 Indicator, Button, or IconPower supply 2 PS2 Power Indicator Codes Link indicator NIC Indicator CodesViewing Status Messages LCD Status MessagesRemoving LCD Status Messages Disabled ErrorRange. Power BatteryFault. Power E122C CPU PowerE1216 RegulatorE1311 Fan module ## ConfigurationRPM exceeding E1313 FanParity error Error. PowerPower cycle Check errorPower. Check E161C Power SupplyE1624 Lost power E1626 Power SupplyE1710 Channel Error on BusReview Clear SELE1714 Unknown Error. ReviewE1715 Fatal I/O E1716 Chipset IerrReconfigure Fault. ReviewE171F PCIe fatal E1810 Hard drive ##But unusable Check DIMMs E2013 Bios unable ConfiguredE1A15 SAS cable B Control panelTimer error E2017 Timer refreshE2019 Parity error E2015E201B Keyboard ConfigurE201C InitializatioDisabled on Error on DimmE2110 Multibit ##. ReseatW1228 W1627 PowerCapacity 24hrSystem Messages Power required RebootingSystem boot Alert! iDRAC6 notMemory disabled Alert! PowerFatal error BootIs installed on Bios UpdateCPU x installed Attempt FailedConfiguration on Bootable media isCPUs with Different cachePlease run Setup Correct Connectors Gate A20 failureEmbedded NICx NICyFound Invalid PCIe cardInternalStorage SlotLine failure at Memory addressValue expecting Memory doubleNo timer tick Mirror modeDIMMs must be AvailableTo install PCI Bios failedError Expected PCIe TrainingSeek error Read faultRequested sector Not foundAmount Shutdown failureSystem memory has ChangedDIMMs should Setup programFollowing DIMMs should Following DIMMs should Match in sizeWill now reset Timer chipSystem Services Counter 2 failedUnexpected Protected modeUnsupported CPU CombinationSystem reset Error has causedInstalled Code updateNot optimal. Recommended Memory Configuration Configuration isWrite fault Write fault on selected drive Mismatch. PSUAlert Messages Diagnostics MessagesOther Information You May Need About Your System Choosing the System Boot Mode Using the System Setup Program and Uefi Boot ManagerResponding to Error Messages Entering the System Setup ProgramUsing the System Setup Program Navigation Keys System if any changes were madeSize, and so on. See Processor Settings Screen System Setup OptionsMain Screen See Integrated Devices ScreenErrors On default To 84-key keyboards Report KeyboardReport default This setting does not affect the operation of the keyboardProcessor Settings Screen Memory Settings ScreenExecute Disable Sata Settings ScreenEnabled default Available power states Processor X ID Cache size, and number of cores of each processorBoot Settings Screen Integrated Devices Screen Serial Communication Screen PCI IRQ Assignments ScreenAttempt fails. This rate should not be adjusted Power Management ScreenEnabled default Operating system is loaded You can configure each option independentlyMemory power to Maximum Performance. In this DBPM, the fan power to Minimum Power,If you select Custom, you can configure each option Fan PowerSystem Security Screen Exit Screen Enables or disables the NMI featureUsing the Uefi Boot Manager Navigation Keys Entering the Uefi Boot ManagerDisplays the Uefi Boot Manager help file One or returns to the previous screenUefi Boot Settings Screen Uefi Boot Manager ScreenUsing the System Password System and Setup Password FeaturesSystem Utilities Screen Using the System Setup Program and Uefi Boot Manager Using the Setup Password Using the System Setup Program and Uefi Boot Manager Entering the iDRAC Configuration Utility IDRAC Configuration UtilityRecommended Tools Installing System ComponentsInside the System Removing and Replacing the Optional Front Bezel Removing the Information Tag Information TagReplacing the Information Tag Opening and Closing the SystemOpening the System Lift up the latch on the cover Closing the SystemRemoving a Drive Blank Hard DrivesRemoving a Hot-Swap Hard Drive Installing a Hard-Drive BlankRemove the front bezel. See Removing the Front Bezel Installing a Hot-Swap Hard Drive Hard drive Drive carrier Installing a Hot-Swap Hard DriveRemoving a Hard Drive From a Hard-Drive Carrier Installing a Hard Drive Into a Hard-Drive CarrierSAS screw hole Removing a Power Supply Power SuppliesRemoving and Replacing a Power Supply Power supply Installing a Power SupplyInstalling the Power Supply Blank Removing the Power Supply BlankExpansion Card Installation Guidelines Expansion CardsInstalling an Expansion Card Close the expansion-card latch. See Figure Removing an Expansion Card Expansion-Card RisersRemoving an Expansion-Card Riser Installing System Components Page Internal SD Module Installing the Internal SD ModuleReplacing an Expansion-Card Riser Opposite side of riserBoard Internal SD Flash Card Installing an Internal SD Flash CardRemoving the Internal SD Module Card Removing an Internal SD Flash Card Internal USB Memory KeyRemoving the Internal USB Cable Internal USB CableUSB memory key Remove the USB cable from the connector on the system board Installing the Internal USB CableVFlash Media 100Installing an iDRAC6 Enterprise Card Installing a VFlash Media CardIDRAC6 Enterprise Card Optional Removing a VFlash Media CardRetention standoff posts Socket Removing an iDRAC6 Enterprise Card103 NIC Hardware KeyCooling Fans 13. Installing a NIC Hardware Key NIC hardware keyRemoving a Cooling Fan Fan assembly Installing System Components105 Replacing a Cooling Fan Removing the Fan Assembly107 Replacing the Fan AssemblyOnly Removing the Plastic Fan Guide Optical DriveReplacing the Plastic Fan Guide 109 Removing an Optical Drive16. Removing the Optical Drive Optical drive Installing an Optical DriveRemoving the Integrated Storage Controller Card Integrated Storage Controller Card111 Intstorage Installing the Integrated Storage Controller CardSAS data cable Cable retention clip 113Removing a RAID Battery RAID BatteryInstalling a RAID Battery Removing the Perc 6/I Battery Cable115 Installing the Perc 6/I Battery CableSystem Memory General Memory Module Installation Guidelines117 Mode-Specific Guidelines118 None All Mirroring 119Mirroring None Installing Memory Modules121 18. Installing and Removing a Memory Module Memory moduleRemoving Memory Modules ProcessorsRemoving a Processor 122123 19. Installing and Removing the Heat Sink Heat sinkInstalling System Components 125 Installing a ProcessorInstalling System Components Replacing the System Battery System Battery127 21. Replacing the System Battery Removing the Control Panel Display Module Control Panel Assembly129 Mounting screws 3 Torx Removing the Control Panel Board Installing the Control Panel Display Module131 SAS Backplane Installing the Control Panel BoardRemoving the SAS Backplane 133 134 System Board Installing a SAS BackplaneRemoving the System Board 135Installing System Components 137 24. Removing and Installing the System Board Retention pinInstalling the System Board 139 140 Troubleshooting Your System Troubleshooting External Connections141 Troubleshooting a USB Device Troubleshooting the Video SubsystemTroubleshooting a NIC Troubleshooting a Serial I/O Device143 Troubleshooting a Wet System 145 Troubleshooting a Damaged SystemTroubleshooting Power Supplies Troubleshooting the System BatteryEnsure that none of the following conditions exist Troubleshooting System Cooling Problems147 Troubleshooting System Memory Troubleshooting a Fan149 Troubleshooting an Internal SD Card Troubleshooting an Optical Drive Troubleshooting an Internal USB Key151 Troubleshooting Hard Drives 153 Troubleshooting a SAS ControllerTry using a different tape cartridge 154 Troubleshooting an External Tape Drive155 Troubleshooting Expansion Cards156 157 Troubleshooting the ProcessorsTroubleshooting Your System System Diagnostics Features Using Dell PowerEdge DiagnosticsRunning the System Diagnostics When to Use the System DiagnosticsUsing the Custom Test Options System Diagnostics Testing OptionsSelecting Devices for Testing Selecting Diagnostics OptionsViewing Information and Results System Board Jumper Settings Disabling a Forgotten PasswordJumpers and Connectors System Board JumpersSystem Board Connectors 165 System Board Connectors Jumpers and Connectors 166 167 Contacting Dell168 Amperes AC Alternating current 169Glossary CPU Central processing unit. See processor DC Direct current 170171 172 173 174 System memory See RAM 175176 177 178 Index 179Using Dell PowerEdge Diagnostics Diagnostics Advanced testing options, 161 testing optionsMicroprocessor See processor 181SD card, 98 system board Post183 System Utilities screen, 72 Uefi Boot Settings screen Front-panel connectors USB cable internal
Related manuals
Manual 38 pages 56.38 Kb Manual 184 pages 23.25 Kb Manual 56 pages 37.07 Kb Manual 210 pages 41.43 Kb Manual 4 pages 41.72 Kb