Spectra Logic T50E Log, Reboot System Perform a Backup, Perform the AutoInstall, Load Cartridges

Page 2

Spectra T50e

Quick Start Guide

3

Perform the AutoInstall

AutoInstall (Firmware and Option Keys)

The USB drive that came in your Document Kit (see Unpack and Verify the Components on page 1) contains the library’s firmware as well as the option keys that you purchased. Follow these steps to load the firmware and keys.

1.Insert the USB drive in the USB port at the back of the library.

2.Plug the power cord in if it is not already connected.

3.Press the front panel power button for two to three seconds.

4.Wait while the library performs its power-on sequence, which typically takes six to nine minutes.

During the AutoInstall process, the library upgrades the firmware from the USB drive, reboots itself, and automatically installs the option keys during the remainder of the power-on sequence.

Important! Do not remove the USB drive until after the Login screen appears, but do not leave the USB drive in the library after the installation.

Stylus—used to navigate in screens.

USB drive

2 Connect power cord

1 Insert USB drive

3 Press power button

Stylus in holder

4

Log In

5

Create a Partition

BlueScale User Interface Log In

After the power-on sequence completes, the login screen displays.

1.Using the stylus, touch (to select) the User box and type su.

2.Leave the password field blank, and select Login.

3.Wait for the initialization process to complete.

4.Close the keyboard by selecting its icon with the stylus.

Note: If you are prompted to calibrate the touch screen, follow the instructions on the screen. You must use the stylus for the calibration procedure to complete successfully.

Partition Creation Follow these steps to allow the library to automatically create a partition.

1.Using the stylus, select Menu > Configuration > Partitions > Automatically create a partition > New.

2.Use the wizard to create the partition, and then choose one option:

ƒSave Library Configuration to USB (recommended)

ƒSave Library Configuration to autosupport@spectralogic.com (recommended)

ƒDon’t Save Library Configuration (not recommended)

3.Select Next and Save.

To manually create partitions, see the Spectra T50e Library User Guide for instructions.

su

1Type “su”

2 Login

3 Wait

4 Close keyboard

6

Load Cartridges

Cartridge Loading If you have only one partition enabled, use Bulk Load for the initial setup. Refer to the Spectra T50e Library User Guide if you have more than one partition.

1.Using the stylus, select Menu > General > Import/Export > Bulk Load. Both left-side magazines release.

2. Remove the bottom left magazine and set it on a stable surface. CAUTION! Be careful while handling fully-loaded magazines as they are heavy!

3.Load the cartridges sequentially starting at slot 1 and continue with the top left-side magazine, if needed. Reinsert the left-side magazine(s) and continue with the right-side magazines, if needed. See the Spectra T50e Library User Guide for information about the expansion slots (slots 48 through 50).

4.Gently push each magazine into the library until it is fully seated and press Stop Importing. The library inventories the cartridges.

7

Reboot

System and

Perform a

Backup

Important! Replace magazines in the same locations.

Left

Right

Access port

Slot 1

(bar code labels must face out)

Host System Reboot Follow these steps:

1.Ensure that your SCSI HBA BIOS has LUN support enabled.

2.Reboot your host system, if needed.

3.Install your backup application, if it is not already installed.

4.Configure the application to work with the Spectra T50e library.

Go to www.spectralogic.com/downloads to download device drivers for the library.

Initial Backup Create a test backup job.

Refer to the documentation that came with your backup application for instructions.

Left-side magazines

 

Expansion slots

Right-side magazines

 

 

 

 

 

 

 

47

 

 

 

 

 

 

23

50

 

 

 

 

 

 

19

49

43

 

 

 

 

 

 

15

48

39

44

 

 

20

 

 

35

 

Top

 

10

11

 

 

31

40

Top

16

9

7

 

 

 

12

6

3

 

 

27

36

 

 

8

5

2

 

 

 

 

32

 

 

1

 

 

 

 

 

28

 

Bottom

4

 

 

 

 

 

Bottom

 

 

 

 

 

 

 

24

Access port

Important! Load cartridges sequentially starting at slot 1.

Spectra Logic Technical Support

If you need assistance, contact us using one of these options.

Option

US, Canada/Outside Europe

Europe, Middle East, and Africa

 

 

 

Email:

support@spectralogic.com

support@spectralogic.com

Web:

www.spectralogic.com/support

www.spectralogic.com/support

Phone:

1.800.227.4637

44 (0) 870.112.2185

 

1.303.449.0160

 

 

 

 

Note: Reference the Spectra T50e Library User Guide for comprehensive instructions on how to operate your new library. Access the manual either on the Product CD or at www.spectralogic.com/documents.

P.N. 90970017, Rev. C

www.spectralogic.com

Page 2 of 2

Image 2
Contents Remove Shipping Key Install the Tape DrivesUnpack Verify Components Connect the CablesLog Reboot System Perform a BackupPerform the AutoInstall Load Cartridges