FieldServer FS-8700-83 instruction manual Status Types and Values

Page 13

FS-8700-83 Gamewell

Page 11 of 24

1.If the Data Type is ‘Any’ then the map descriptor will be used to store data from message with any status.

2.The state reported is filtered and must match the Data_Type for the associated array to be updated. For example, if the Data_Type of a MapDesc is ‘Alarms’ and a message is received that reports a Fault then the map descriptor will not be used to store the data from the message.

3.Normally, user’s are interested in the Status of a device / circuit / panel but they may also be interested in the cause (or the ‘action’ in Gamewell terminology) of the message. When you specify the Data_Type as ‘Action Numbers’ then the driver will store a value which can be used to look up the action that produced the message. The most recent action number is stored over any older value. (The driver does not provide an event log.)

4.Instead of storing a value to indicate the action, the driver can set a bit whose offset indicates the action. For example, action 30 will cause the 30th bit to be set. Action bits are stored retentively. This means that when a new action is reported the previous bits are left set and a new bit is set too.

5.What happens if a message arrives that reports an alarm and you don’t have a map descriptor with a Data_Type capable of storing an alarm. You can make a catch all map descriptor and use the ‘Dump’ Data_Type to tell the driver to store the whole message in ASCII format in a data array so that you can inspect it. You can also use this map descriptor to tell the driver to dump the ignored message to the error log.

6.3Status Types and Values

Generally, the driver stores non-zero values to indicate the state of a device / circuit / panel based on the ‘status’ field of the incoming message. The specific non-zero value can be found in the following table. The value have been chosen so that they correspond to different bits.

Status

Value Stored

Alarm

1

Fault

2

Event

4

Bus

8

Comm

16

Control

32

Ack

64

Sig Sil

128

Supv

512

Genr

1024

Thus if a map descriptor has its Data_Type = ‘Any’ and two messages are received , one an alarm and one an event, then the value of the array element will be set to 1 + 4 = 5. Thus the value is non-zero to report the not-normal state but inspection of the value allows you to determine the specific stat.

The value’s can be changed by using the method below to add, but when you add, use the existing name and a new value.

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: support@fieldserver.com

Image 13
Contents Effective for all systems manufactured after May 1 Supplement to the FieldServer Instruction ManualTable of Contents 2Provided by user 1Supplied by FieldServer Technologies for this driverRS-485/RS-232 Pigtail for RJ45 port Driver ManualHardware Connections Section Title 1Data ArraysColumn Title Function Legal Values Example2Client Side Connections Default 1 secondNone 3Client Side Nodes FieldServer Related Map Descriptor Parameters 4Client Side Map DescriptorsDriver Related Map Descriptor Parameters Value Timing ParametersMap Descriptor Example 1 Store data from incoming messages Daack 2Data Types 1Driver Limitations & ExclusionsStatus Status Types and Values5Action Types 4When do Data Arrays get cleared ResetAdding a New Status Type Fire Alarm System SetupSecurity Alarm Pre AlarmFS-8700-83 Gamewell Adding new Action Types Example 1 Filtering Data 6Advanced Map Descriptor ExamplesExample 2 Action Numbers Example 3 Action Bits Example 4 Ignored Messages 2Driver Stats 1ICTimeoutOffset is obtained by multiplying the port number by Array Offset Driver stores the following dataRevision History

FS-8700-83 specifications

The FieldServer FS-8700-83 is a robust communication gateway designed for seamless interoperability between building automation systems and various industrial protocols. This versatile device is integral in simplifying the connectivity challenges often faced in diverse operational environments.

One of the main features of the FS-8700-83 is its extensive protocol support. It can facilitate communication between a multitude of protocols including BACnet, Modbus, and LonWorks, enabling integration across different systems with ease. The device is equipped with multiple serial and Ethernet ports, allowing for flexible configuration options to meet the specific needs of various projects.

In terms of technology, the FS-8700-83 employs a powerful processor to handle data exchange efficiently. Its advanced firmware supports a range of applications, making it suitable for both current and future needs. The gateway is also designed to handle high-volume data traffic, ensuring that information flows smoothly even in complex setups.

Another significant characteristic of the FS-8700-83 is its user-friendly interface. The device features a web-based configuration tool, enabling users to easily set up and monitor the system from any standard web browser. This simplifies the installation process and reduces the need for extensive training, making it accessible for technicians and engineers alike.

The FS-8700-83 supports extensive data logging capabilities, which can be invaluable for system troubleshooting and performance analysis. Users can capture and analyze historical data, allowing for informed decision-making and optimization of building operations over time.

In terms of reliability, the FS-8700-83 is designed with durability in mind, making it suitable for various environments and conditions. Its compact form factor facilitates deployment in space-constrained areas, while ensuring high performance and resilience.

Security is also a priority for the FS-8700-83. The device incorporates advanced security protocols to safeguard against unauthorized access, ensuring that sensitive data remains protected.

In summary, the FieldServer FS-8700-83 stands out as a powerful, flexible, and user-friendly solution for building automation and industrial communication challenges. With its extensive protocol support, robust technology, intuitive interface, and strong security features, it serves as an essential tool for integrating diverse systems and enhancing operational efficiency. The FS-8700-83 is an investment in future-proof connectivity and scalability for modern automation projects.