FieldServer FS-8700-83 instruction manual Example 2 Action Numbers

Page 19

FS-8700-83 Gamewell

Page 17 of 24

Example 2 : Action Numbers

You can have the driver store a value corresponding to the contents of the action field reported in the incoming messages. Actions are brief descriptions of the event that caused the message to be generated. A table of values vs. descriptions is provided in section 6.5. The driver stores the most recent action number, overwriting the previously stored action numbers. The driver does not keep an event log. The action number’s are set to zero, if the clear_on_reset is set to ‘yes’ and a system reset message is received.

For example, if the string ‘Fire Alarm in’ is contained in the action field of the message the driver would store an action value of 11.

This map descriptor can be used as well as the any of the map descriptors shown in previous examples. Thus you can have one (or more) map descrriptor storing the state and one storing the action number.

Map_Descriptors

 

Data_Array_Name

,

Data_Array_Offset,

Function,

node_name,

ckt

,

Length

,

Data_Type

,

Clear_on_Reset

Map_Descriptor_Name,

Ckt1128_data12

,

DA_ACTION128

,

000

,

passive ,

panel1

,

128

,

127

,

Action_Numbers ,

yes

Using this data_Type the driver stores a value corresponding to the contents of the action field portion of the message sent by the panel. A table in section 6.5 provides a list of values vs. action descriptions.

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: support@fieldserver.com

Image 19
Contents Effective for all systems manufactured after May 1 Supplement to the FieldServer Instruction ManualTable of Contents Driver Manual 1Supplied by FieldServer Technologies for this driver2Provided by user RS-485/RS-232 Pigtail for RJ45 portHardware Connections Example 1Data ArraysSection Title Column Title Function Legal Values2Client Side Connections Default 1 secondNone 3Client Side Nodes FieldServer Related Map Descriptor Parameters 4Client Side Map DescriptorsDriver Related Map Descriptor Parameters Value Timing ParametersMap Descriptor Example 1 Store data from incoming messages Daack 2Data Types 1Driver Limitations & ExclusionsStatus Status Types and Values5Action Types 4When do Data Arrays get cleared ResetAdding a New Status Type Pre Alarm System SetupFire Alarm Security AlarmFS-8700-83 Gamewell Adding new Action Types Example 1 Filtering Data 6Advanced Map Descriptor ExamplesExample 2 Action Numbers Example 3 Action Bits Example 4 Ignored Messages 2Driver Stats 1ICTimeoutOffset is obtained by multiplying the port number by Array Offset Driver stores the following dataRevision History

FS-8700-83 specifications

The FieldServer FS-8700-83 is a robust communication gateway designed for seamless interoperability between building automation systems and various industrial protocols. This versatile device is integral in simplifying the connectivity challenges often faced in diverse operational environments.

One of the main features of the FS-8700-83 is its extensive protocol support. It can facilitate communication between a multitude of protocols including BACnet, Modbus, and LonWorks, enabling integration across different systems with ease. The device is equipped with multiple serial and Ethernet ports, allowing for flexible configuration options to meet the specific needs of various projects.

In terms of technology, the FS-8700-83 employs a powerful processor to handle data exchange efficiently. Its advanced firmware supports a range of applications, making it suitable for both current and future needs. The gateway is also designed to handle high-volume data traffic, ensuring that information flows smoothly even in complex setups.

Another significant characteristic of the FS-8700-83 is its user-friendly interface. The device features a web-based configuration tool, enabling users to easily set up and monitor the system from any standard web browser. This simplifies the installation process and reduces the need for extensive training, making it accessible for technicians and engineers alike.

The FS-8700-83 supports extensive data logging capabilities, which can be invaluable for system troubleshooting and performance analysis. Users can capture and analyze historical data, allowing for informed decision-making and optimization of building operations over time.

In terms of reliability, the FS-8700-83 is designed with durability in mind, making it suitable for various environments and conditions. Its compact form factor facilitates deployment in space-constrained areas, while ensuring high performance and resilience.

Security is also a priority for the FS-8700-83. The device incorporates advanced security protocols to safeguard against unauthorized access, ensuring that sensitive data remains protected.

In summary, the FieldServer FS-8700-83 stands out as a powerful, flexible, and user-friendly solution for building automation and industrial communication challenges. With its extensive protocol support, robust technology, intuitive interface, and strong security features, it serves as an essential tool for integrating diverse systems and enhancing operational efficiency. The FS-8700-83 is an investment in future-proof connectivity and scalability for modern automation projects.