FieldServer FS-8700-83 instruction manual Driver stores the following data, Array Offset

Page 23

FS-8700-83 Gamewell

Page 21 of 24

The driver stores the following data.

 

 

PORT

 

 

Description

0

1

2

3

8

 

 

Array Offset

 

 

0

30

60

90

 

240

Available for future use

1

31

61

91

 

241

Available for future use

2

32

62

92

 

242

Available for future use

3

33

63

93

 

243

Available for future use

4

34

64

94

 

244

Number of bytes sent by client driver

5

35

65

95

 

245

Number of messages sent by client

6

36

66

96

 

246

Number of reponse messages received by client

7

37

67

97

 

247

Number of response bytes received by client

 

 

 

 

 

 

Number of times client has timeout out waiting for (response)

8

38

68

98

 

248

prompt

 

 

 

 

 

 

Number of times client has timeout out waiting for (response)

9

39

69

99

 

249

prompt

10

40

70

100

 

250

Number of Supervision Messages Sent

11

41

71

101

 

251

Number of Supervision Messages Received

12

42

72

102

 

252

Number of Supervision Messages Responses Sent

13

43

73

103

 

253

Number of Supervision Messages Responses Received

14

44

74

104

 

254

Number of Supervision Messages Received with a protocol

 

error

 

 

 

 

 

 

Number of times that message containing status information

15

45

75

105

 

255

was found

 

 

 

 

 

 

Number of times that message parsing failed because an

16

46

76

106

 

256

unrecognized status type was found.

 

 

 

 

 

 

Number of time that a message containing node information

17

47

77

107

 

257

was found

18

48

78

108

 

258

Number of times that oarsing failed because 2 CR's were not

 

found.

 

 

 

 

 

 

Number of times that message parsing failed because an

19

49

79

109

 

259

unrecognized status type was found.

20

50

80

110

 

260

Number of times that parsing completed

 

 

 

 

 

 

Number of times that the client timed out waiting for a

21

51

81

111

 

261

message to be sent

 

 

 

 

 

 

Number of times that the client timed out waiting for a

22

52

82

112

 

262

response to a supervision query

23

53

83

113

 

263

Number of times that a reset command was received.

24

54

84

114

 

264

Number of times that a Ack command was received.

25

55

85

115

 

265

Number of times that a Silence command was received.

 

 

 

 

 

 

Number of times that the slave received na unregonized

26

56

86

116

 

266

command

27

57

87

117

 

267

Number of times that the slave received a command

 

message

28

58

88

118

 

268

Number of times that the slave received a message

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: support@fieldserver.com

Image 23
Contents Effective for all systems manufactured after May 1 Supplement to the FieldServer Instruction ManualTable of Contents Driver Manual 1Supplied by FieldServer Technologies for this driver2Provided by user RS-485/RS-232 Pigtail for RJ45 portHardware Connections Example 1Data ArraysSection Title Column Title Function Legal ValuesNone Default 1 second2Client Side Connections 3Client Side Nodes Driver Related Map Descriptor Parameters 4Client Side Map DescriptorsFieldServer Related Map Descriptor Parameters Value Timing ParametersMap Descriptor Example 1 Store data from incoming messages Daack 2Data Types 1Driver Limitations & ExclusionsStatus Status Types and ValuesAdding a New Status Type 4When do Data Arrays get cleared Reset5Action Types Pre Alarm System SetupFire Alarm Security AlarmFS-8700-83 Gamewell Adding new Action Types Example 1 Filtering Data 6Advanced Map Descriptor ExamplesExample 2 Action Numbers Example 3 Action Bits Example 4 Ignored Messages Offset is obtained by multiplying the port number by 1ICTimeout2Driver Stats Array Offset Driver stores the following dataRevision History

FS-8700-83 specifications

The FieldServer FS-8700-83 is a robust communication gateway designed for seamless interoperability between building automation systems and various industrial protocols. This versatile device is integral in simplifying the connectivity challenges often faced in diverse operational environments.

One of the main features of the FS-8700-83 is its extensive protocol support. It can facilitate communication between a multitude of protocols including BACnet, Modbus, and LonWorks, enabling integration across different systems with ease. The device is equipped with multiple serial and Ethernet ports, allowing for flexible configuration options to meet the specific needs of various projects.

In terms of technology, the FS-8700-83 employs a powerful processor to handle data exchange efficiently. Its advanced firmware supports a range of applications, making it suitable for both current and future needs. The gateway is also designed to handle high-volume data traffic, ensuring that information flows smoothly even in complex setups.

Another significant characteristic of the FS-8700-83 is its user-friendly interface. The device features a web-based configuration tool, enabling users to easily set up and monitor the system from any standard web browser. This simplifies the installation process and reduces the need for extensive training, making it accessible for technicians and engineers alike.

The FS-8700-83 supports extensive data logging capabilities, which can be invaluable for system troubleshooting and performance analysis. Users can capture and analyze historical data, allowing for informed decision-making and optimization of building operations over time.

In terms of reliability, the FS-8700-83 is designed with durability in mind, making it suitable for various environments and conditions. Its compact form factor facilitates deployment in space-constrained areas, while ensuring high performance and resilience.

Security is also a priority for the FS-8700-83. The device incorporates advanced security protocols to safeguard against unauthorized access, ensuring that sensitive data remains protected.

In summary, the FieldServer FS-8700-83 stands out as a powerful, flexible, and user-friendly solution for building automation and industrial communication challenges. With its extensive protocol support, robust technology, intuitive interface, and strong security features, it serves as an essential tool for integrating diverse systems and enhancing operational efficiency. The FS-8700-83 is an investment in future-proof connectivity and scalability for modern automation projects.