Table 2: | Drive specifications summary for 500 and 250 Gbyte models |
| |||
|
|
|
|
| |
Drive specification | ST3500414CS |
| ST3500312CS | ST3250312CS | |
|
|
|
|
| |
Formatted capacity | 500 Gbytes |
| 250 Gbytes | ||
(512 bytes/sector)* |
|
|
|
| |
|
|
|
|
| |
Guaranteed sectors | 976,773,168 |
|
| 488,397,168 | |
|
|
|
|
|
|
Heads |
| 2 |
|
| 1 |
|
|
|
|
|
|
Discs |
| 1 |
|
|
|
|
|
|
|
| |
Bytes per sector | 512 |
|
|
| |
|
|
|
|
| |
Default sectors per track | 63 |
|
|
| |
|
|
|
|
| |
Default read/write heads | 16 |
|
|
| |
|
|
|
|
| |
Default cylinders | 16,383 |
|
|
| |
|
|
|
| ||
Recording density | 1417 kbits/in max |
|
| ||
|
|
|
|
| |
Track density |
| 236 ktracks/in avg |
|
| |
|
|
|
|
| |
Areal density |
| 341.5 Gbits/in2 avg |
|
| |
Spindle speed |
| 5,900 RPM |
|
| |
|
|
|
| ||
Internal data transfer rate | 1285 Mbits/sec max |
|
| ||
|
|
|
| ||
Sustained data transfer rate | 120 Mbytes/sec max |
|
| ||
|
|
|
| ||
I/O | 300 Mbytes/sec max |
|
| ||
|
|
|
| ||
ATA | PIO modes |
|
| ||
|
| Multiword DMA modes |
|
| |
|
| Ultra DMA modes |
|
| |
|
|
|
|
| |
Cache buffer |
| 16 Mbytes |
| 8 Mbytes |
|
|
|
|
|
|
|
Height (max) |
| 20.20 mm (0.795 inches) |
|
| |
|
|
|
|
| |
Width (max) |
| 101.85 mm (4.010 inches) |
|
| |
|
|
|
|
| |
Length (max) |
| 146.99 mm (5.787 inches) |
|
| |
|
|
|
| ||
Weight (typical) | 380 grams (0.838 lb.) |
|
| ||
|
|
|
| ||
Average latency | 5.1 msec |
|
| ||
|
|
|
| ||
<6 sec typical |
|
| |||
|
|
|
| ||
Standby to ready | <6 sec typical |
|
| ||
|
|
|
| ||
<1.0 msec typical read; |
|
| |||
|
| <1.2 msec typical write |
|
| |
|
|
|
| ||
Average seek, read | <14.0 msec typical |
|
| ||
|
|
|
| ||
Average seek, write | 5.1 msec |
|
| ||
|
|
|
| ||
Startup current (typical) 12V (peak) | 2.0 amps |
|
| ||
|
|
|
| ||
Voltage tolerance (including noise) | 5V ± 5% |
|
| ||
|
| 12V ± 10% |
|
| |
|
|
|
| ||
Operating temperature | 0° to 75°C |
|
| ||
(Drive Case temperature) |
|
|
|
| |
Nonoperating temperature (Ambient) |
|
| |||
|
|
|
| ||
Temperature gradient (max) | 20°C per hour max (operating) |
|
| ||
|
| 30°C per hour max (nonoperating) |
| ||
|
|
|
| ||
Relative humidity | 5% to 90% (operating) |
|
| ||
|
| 5% to 95% (nonoperating) |
|
| |
Relative humidity gradient | 30% per hour max |
|
| ||
|
|
|
| ||
Wet bulb temperature (max) | 37.7°C max (operating) |
|
| ||
|
| 40.0°C max (nonoperating) |
|
| |
|
|
|
| ||
Altitude, operating |
|
| |||
|
|
|
| ||
Altitude, nonoperating |
|
| |||
(below mean sea level, max) |
|
| |||
|
|
|
|
|
|
6 | Pipeline HD.2 Series SATA Product Manual, Rev. A |