FieldServer FS-8704-13 Configuring the FieldServer as a GE-SRTP Driver Client, Data Arrays

Page 6

FS-8704-13 GE-SRTP

Driver Manual

4.Configuring the FieldServer as a GE-SRTP Driver Client

For a detailed discussion on FieldServer configuration, please refer to the instruction manual for the FieldServer. The information that follows describes how to expand upon the factory defaults provided in the configuration files included with the FieldServer (See “.csv” files on the driver diskette).

This section documents and describes the parameters necessary for configuring the FieldServer to communicate with a GE-SRTP Driver Server.

The configuration file tells the FieldServer about its interfaces, and the routing of data required. In order to enable the FieldServer for GE-SRTP Driver communications, the driver independent FieldServer buffers need to be declared in the “Data Arrays” section, the destination device addresses need to be declared in the “Client Side Nodes” section, and the data required from the servers needs to be mapped in the “Client Side Map Descriptors” section. Details on how to do this can be found below.

Note that in the tables, * in dicates an optional parameter, with the bold legal value being the default.

4.1 Data Arrays

Section Title

 

 

Data_Arrays

 

 

Column Title

Function

Legal Values

Data_Array_Name

Provide name for Data Array

Up to 15 alphanumeric

 

 

characters

Data_Format

Provide data format. Each data array can only

FLOAT, BIT, UInt16, SInt16,

 

take on one format.

Packed_Bit, Byte,

 

 

Packed_Byte, Swapped_Byte

Data_Array_Length

Number of Data Objects. Must be larger than

1-10,000

 

the data storage area required for the data

 

 

being placed in this array.

 

 

 

 

Example

//Data Arrays

Data_Arrays

 

 

Data_Array_Name,

Data_Format,

Data_Array_Length

DA_AI_01,

UInt16,

200

DA_AO_01,

UInt16,

200

DA_DI_01,

Byte,

200

DA_DO_01,

Byte,

200

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 (408) 262-2299 fax: (408) 262-9042

Visit our website: www.fieldserver.com E-mail: support@fieldserver.com Page 4

Image 6
Contents FS-8704-13 GE-SRTP Ethernet Driver Driver ManualTable of Contents GE-SRTP Driver Description Driver Scope of Supply Supplied by FieldServer Technologies for this driverProvided by user Connection Diagram Hardware ConnectionsGE-SRTP Configuring the FieldServer as a GE-SRTP Driver Client Data ArraysClient Side Connections Client Side NodesRDBC, WRBC, Wrbx Driver Specific Map Descriptor Parameters Timing ParametersMap Descriptor Example 1 Simple Read Rdbc =Map Descriptor Example 2 Simple Write DaaoMap Descriptor Example 3 Handling Bits Configuring the FieldServer as a GE-SRTP Driver Server Server Side Connections Server Side Nodes Driver Specific Map Descriptor Parameters Map Descriptor Example TablerDriver Notes Driver StatsDriver Error messages Scaling

FS-8704-13 specifications

The FieldServer FS-8704-13 is an advanced protocol gateway specifically designed for integrating diverse building automation systems and data communication protocols. This powerful device serves as a bridge between multiple communication protocols, making it an invaluable tool for facility managers and system integrators aiming to create seamless integration of disparate systems.

One of the main features of the FS-8704-13 is its extensive protocol support. The device can communicate with protocols such as Modbus, BACnet, LonWorks, and many others, allowing for versatile compatibility with a wide variety of automation equipment and devices. This wide-ranging support makes it suitable for energy management systems, HVAC systems, lighting controls, and security systems.

The FS-8704-13 utilizes a high-performance processor that ensures quick data processing and reliable communication even under heavy traffic conditions. The device is equipped with multiple communication ports, including Ethernet and RS-232/RS-485 interfaces, enabling it to connect to various types of network environments effortlessly. The dual Ethernet ports facilitate network redundancy, ensuring that communication remains uninterrupted.

Another notable characteristic of the FS-8704-13 is its user-friendly interface, which includes an intuitive web-based dashboard for easy configuration and monitoring. This simplifies the setup process and allows users to visualize system statuses in real-time. Advanced configuration options enable users to customize data mapping and communication parameters to meet specific project requirements.

The FS-8704-13 is built with robustness in mind; it adheres to industry standards for durability and reliability. This makes it suitable for installation in demanding environments such as commercial buildings, industrial facilities, and critical infrastructure. Additionally, the device is equipped with security features, including user authentication and encrypted communication, to protect sensitive data from unauthorized access.

In terms of scalability, the FS-8704-13 is designed to grow with the needs of a facility. Its modular architecture allows for expansion and integration of new protocols and devices as they become available, ensuring that the system remains current and effective at managing building operations.

Overall, the FieldServer FS-8704-13 stands out as a highly versatile and efficient solution for integration challenges faced in today's complex building automation landscape. With its rich feature set, robust technology, and ease of use, it positions itself as a vital asset for improving operational efficiency and reducing operational costs in any facility.