3-8. PC Health Status
FAN Fail Alarm Selectable:
This item selects the fan that will be monitored for malfunction.
Shutdown When CPUFAN Fail:
When set to [Enabled], the system will be shut down if the CPU fan is not running.
CPU FanEQ Speed Control: (For
This item allows you to control the CPU fan speed down to a specific percentage.
When set to a specific percentage, the CPU fan speed will run at the percentage you set in this item if the temperature limit set in the item “Active Temperature” is not exceeded.
The CPU fan speed will run at 100% regardless of what the percentage you set in this item if the temperature limit set in the item “Active Temperature” is exceeded.
Active Temperature:
This item sets the temperature limit that would activate the function of “CPU FanEQ Speed Control” option.
Shutdown Temperature:
This item sets the temperature that would shutdown the system automatically in order to prevent system overheats.
CPU Warning Temperature:
This item selects the CPU’s warning temperature limit. Once the system has detected that the CPU’s temperature exceeded the limit, warning beeps will sound.
NOTE: The onboard hardware monitor function is capable of detecting these system health conditions. If you want a warning message to